28 research outputs found

    Usefulness of a new malodour-compound detection portable device in oral malodour diagnosis.

    Full text link
    peer reviewedA new device (BB Checker) able to detect malodour compounds has recently been made available. This retrospective analysis aimed at evaluating the usefulness of this device as adjunct tool for the diagnosis of oral malodour. Data from 100 consecutive volunteers with bad breath complaints attending their first consultation at a halitosis clinic were analysed. In addition to the standard protocol (organoleptic ratings from mouth and nose air, and from tongue coating when present; OralChroma and Halimeter measurements from mouth air; and intra-oral examinations), oral, exhaled and nasal air samples were examined with the BB Checker. We could not establish a correlation between the BB Checker values and the organoleptic scores, or the sulfur-compound levels determined by the OralChroma or the Halimeter (R 0.05). The overall sensitivity and specificity of the new device did not exceed the 50%. The correlations between the organoleptic scores and the OralChroma and the Halimeter measurements were good and in line with previous reports (R between 0.56 and 0.73). Our results do not favour the use of the BB Checker as adjunct tool in the diagnosis of oral malodour

    Changing care pathways and between-center practice variations in intensive care for traumatic brain injury across Europe

    Get PDF
    Purpose: To describe ICU stay, selected management aspects, and outcome of Intensive Care Unit (ICU) patients with traumatic brain injury (TBI) in Europe, and to quantify variation across centers. Methods: This is a prospective observational multicenter study conducted across 18 countries in Europe and Israel. Admission characteristics, clinical data, and outcome were described at patient- and center levels. Between-center variation in the total ICU population was quantified with the median odds ratio (MOR), with correction for case-mix and random variation between centers. Results: A total of 2138 patients were admitted to the ICU, with median age of 49 years; 36% of which were mild TBI (Glasgow Coma Scale; GCS 13–15). Within, 72 h 636 (30%) were discharged and 128 (6%) died. Early deaths and long-stay patients (> 72 h) had more severe injuries based on the GCS and neuroimaging characteristics, compared with short-stay patients. Long-stay patients received more monitoring and were treated at higher intensity, and experienced worse 6-month outcome compared to short-stay patients. Between-center variations were prominent in the proportion of short-stay patients (MOR = 2.3, p < 0.001), use of intracranial pressure (ICP) monitoring (MOR = 2.5, p < 0.001) and aggressive treatme

    Extracorporeal Membrane Oxygenation for Severe Acute Respiratory Distress Syndrome associated with COVID-19: An Emulated Target Trial Analysis.

    Get PDF
    RATIONALE: Whether COVID patients may benefit from extracorporeal membrane oxygenation (ECMO) compared with conventional invasive mechanical ventilation (IMV) remains unknown. OBJECTIVES: To estimate the effect of ECMO on 90-Day mortality vs IMV only Methods: Among 4,244 critically ill adult patients with COVID-19 included in a multicenter cohort study, we emulated a target trial comparing the treatment strategies of initiating ECMO vs. no ECMO within 7 days of IMV in patients with severe acute respiratory distress syndrome (PaO2/FiO2 <80 or PaCO2 ≥60 mmHg). We controlled for confounding using a multivariable Cox model based on predefined variables. MAIN RESULTS: 1,235 patients met the full eligibility criteria for the emulated trial, among whom 164 patients initiated ECMO. The ECMO strategy had a higher survival probability at Day-7 from the onset of eligibility criteria (87% vs 83%, risk difference: 4%, 95% CI 0;9%) which decreased during follow-up (survival at Day-90: 63% vs 65%, risk difference: -2%, 95% CI -10;5%). However, ECMO was associated with higher survival when performed in high-volume ECMO centers or in regions where a specific ECMO network organization was set up to handle high demand, and when initiated within the first 4 days of MV and in profoundly hypoxemic patients. CONCLUSIONS: In an emulated trial based on a nationwide COVID-19 cohort, we found differential survival over time of an ECMO compared with a no-ECMO strategy. However, ECMO was consistently associated with better outcomes when performed in high-volume centers and in regions with ECMO capacities specifically organized to handle high demand. This article is open access and distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/)

    A new method of choice for organoleptic scoring: The negative-pressure technique

    No full text
    AIM: To examine an organoleptic scoring method (OLS) whereby the sample is collected by negative pressure in a syringe and is subsequently smelled and rated away from the patient. MATERIALS AND METHODS: Data of 476 patients visiting a specialized halitosis clinic in Leuven (Belgium) were reviewed retrospectively. Organoleptic (with the classic and with the negative-pressure method) and instrumental (with the Halimeter® and OralChroma™ ) ratings of breath odour were retrieved from patient files together with the final diagnosis. The correlations between the different methods were examined (Spearman correlation coefficient) as well as the positive (PPV) and negative predictive value (NPV), sensitivity and specificity of all methods. RESULTS: Both methods of OLS correlated similarly with the instrumental measurements (Halimeter® and OralChroma™ ). Analysis of PPV, NPV, sensitivity and specificity of both methods of examination showed that the negative-pressure method performed best. CONCLUSION: The negative-pressure method is a valid method for organoleptic scoring of the breath odour and performs as good as the classic organoleptic method.status: publishe

    Periodontal diseases as a source of halitosis: a review of the evidence and treatment approaches for dentists and dental hygienists

    No full text
    Bad breath (halitosis) is an important social complaint. In most cases (≥90%), the cause of halitosis can be found within the oral cavity. Under this circumstance, the term oral malodor applies. It affects both healthy and periodontally diseased individuals. Oral malodor is mainly caused by a microbial degradation of both sulfur-containing and nonsulfur-containing amino acids into volatile, bad-smelling gases. Anaerobic gram-negative bacteria, the same species that have been linked to periodontal diseases, are especially involved in this process, explaining why clinicians often associate oral malodor with periodontitis. Some volatile organic compounds render patients more susceptible to periodontitis and this supports the malodor-periodontitis link. This review investigates the interaction between oral malodor and periodontal diseases. Pro and con arguments regarding the mechanisms of halitosis and clinical implications will be presented. In general, however, the impact of tongue coatings has been found to be the dominant factor, besides gingivitis and periodontitis. The last part of this review discusses the treatment of bad breath, with different options.status: publishe

    A new method of choice for organoleptic scoring: The negative-pressure technique.

    Full text link
    peer reviewedAIM: To examine an organoleptic scoring method (OLS) whereby the sample is collected by negative pressure in a syringe and is subsequently smelled and rated away from the patient. MATERIALS AND METHODS: Data of 476 patients visiting a specialized halitosis clinic in Leuven (Belgium) were reviewed retrospectively. Organoleptic (with the classic and with the negative-pressure method) and instrumental (with the Halimeter® and OralChroma(™) ) ratings of breath odour were retrieved from patient files together with the final diagnosis. The correlations between the different methods were examined (Spearman correlation coefficient) as well as the positive (PPV) and negative predictive value (NPV), sensitivity and specificity of all methods. RESULTS: Both methods of OLS correlated similarly with the instrumental measurements (Halimeter® and OralChroma(™) ). Analysis of PPV, NPV, sensitivity and specificity of both methods of examination showed that the negative-pressure method performed best. CONCLUSION: The negative-pressure method is a valid method for organoleptic scoring of the breath odour and performs as good as the classic organoleptic method

    Usefulness of a new malodour-compound detection portable device in oral malodour diagnosis

    No full text
    A new device (BB Checker®) able to detect malodour compounds has recently been made available. This retrospective analysis aimed at evaluating the usefulness of this device as adjunct tool for the diagnosis of oral malodour. Data from 100 consecutive volunteers with bad breath complaints attending their first consultation at a halitosis clinic were analysed. In addition to the standard protocol (organoleptic ratings from mouth and nose air, and from tongue coating when present; OralChroma™ and Halimeter® measurements from mouth air; and intra-oral examinations), oral, exhaled and nasal air samples were examined with the BB Checker®. We could not establish a correlation between the BB Checker® values and the organoleptic scores, or the sulfur-compound levels determined by the OralChroma™ or the Halimeter® (R 0.05). The overall sensitivity and specificity of the new device did not exceed the 50%. The correlations between the organoleptic scores and the OralChroma™ and the Halimeter® measurements were good and in line with previous reports (R between 0.56 and 0.73). Our results do not favour the use of the BB Checker® as adjunct tool in the diagnosis of oral malodour.status: publishe

    Premature stimulation of rat sucrase-isomaltase (SI) by exogenous insulin and the analog B-Asp10 is regulated by a receptor-mediated signal triggering SI gene transcription.

    No full text
    The mechanism(s) by which insulin enhance prematurely the activity of brush border membrane (BBM) hydrolases in rat immature intestine is unknown. Therefore, we have compared the responses of four BBM enzymes [sucrase-isomaltase (SI), maltase, lactase-phloridzine hydrolase (LPH), and aminopeptidase] with exogenous insulin, the analog B-Asp10, IGF-I, and antireceptor MAb [insulin-receptor (IR) MAb] given to preweaning pups. Low doses of insulin caused a precocious induction of SI and of SI mRNA and stimulated maltase activity without effect on LPH nor on aminopeptidase activities. IGF-I given at the same dose as that of insulin had no detectable effect on these enzymes. Administration to sucklings of IR MAb prevented the effect of endogenous insulin by inhibiting the expression of SI and maltase without effect on LPH activity. B-Asp10, an insulin analogue that exhibits in vitro a 3.5-fold increase in receptor affinity with sustained signaling of the receptor tyrosine kinase, caused an overexpression of SI by 3.5-fold and of maltase by 1.5-fold compared with equivalent doses of normal insulin. The premature increases in SI activity, SI mRNA, and maltase activity in response to insulin were dose-dependent and were associated with dose-dependent increases in intracellular spermine and spermidine concentrations. In conclusion, these data suggest that the premature induction of SI by insulin is mediated by a dose-dependent signal initiated by binding of the hormone to its intestinal receptor, which after transduction into the cell indirectly triggers the transcription of the SI gene, possibly by changes in intracellular polyamine concentrations

    Expression of insulin receptors and of 60-kDa receptor substrate in rat mature and immature enterocytes

    No full text
    The mechanism(s) by which rat immature enterocytes exhibit increased responsiveness to insulin before weaning is unknown. Therefore, we have analyzed the distribution, ontogeny, and molecular properties of insulin receptors (IR) and of related substrates in immature and mature enterocytes. IR were studied by radioligand binding assays, cross-linking labeling, immunohistochemistry, and in vitro phosphorylated substrates by immunoprecipitation. Regardless of age, 125I-insulin binding to IR was five times higher in crypt cells than in villus cells and two times higher in the ileum than in the jejunum. Binding capacity to villus cells from sucklings (day 14) exceeded three times that of older animals (day 30 and day 60). Scatchard analysis of equilibrium binding data confirmed an age-related decrease in low- and high-affinity receptor classes without change in affinity constants. In concordance, both alpha- and beta-IR subunits were more abundant in immature than in mature membranes. In vitro, insulin elicited the phosphorylation of three membrane proteins (96, 60 and 42 kDa), whose signals were virtually inhibited by preincubating membranes with antireceptor monoclonal antibodies. By immunoprecipitation, the 60-kDa signal was rapidly detected as a tyrosine-phosphorylated protein, expressed in mature and immature membranes, and identified as a receptor substrate phosphorylated in vitro by the IR tyrosine kinase. In conclusion, 1) increased responsiveness of rat immature enterocytes to insulin could be related to high membrane concentrations of IR and 2) normal rat enterocytes express a 60-kDa phosphotyrosine protein identified as a direct substrate of the IR tyrosine kinase
    corecore