960 research outputs found

    High-Throughput and Accurate 3D Scanning of Cattle Using Time-of-Flight Sensors and Deep Learning

    Full text link
    We introduce a high throughput 3D scanning solution specifically designed to precisely measure cattle phenotypes. This scanner leverages an array of depth sensors, i.e. time-of-flight (Tof) sensors, each governed by dedicated embedded devices. The system excels at generating high-fidelity 3D point clouds, thus facilitating an accurate mesh that faithfully reconstructs the cattle geometry on the fly. In order to evaluate the performance of our system, we have implemented a two-fold validation process. Initially, we test the scanner's competency in determining volume and surface area measurements within a controlled environment featuring known objects. Secondly, we explore the impact and necessity of multi-device synchronization when operating a series of time-of-flight sensors. Based on the experimental results, the proposed system is capable of producing high-quality meshes of untamed cattle for livestock studies

    Non-invasive brain stimulation techniques for chronic pain (Review)

    Get PDF
    Background: This is an updated version of the original Cochrane Review published in 2010, Issue 9, and last updated in 2014, Issue 4. Non-invasive brain stimulation techniques aim to induce an electrical stimulation of the brain in an attempt to reduce chronic pain by directly altering brain activity. They include repetitive transcranial magnetic stimulation (rTMS), cranial electrotherapy stimulation (CES), transcranial direct current stimulation (tDCS), transcranial random noise stimulation (tRNS) and reduced impedance non-invasive cortical electrostimulation (RINCE). Objectives: To evaluate the efficacy of non-invasive cortical stimulation techniques in the treatment of chronic pain. Search methods: For this update we searched CENTRAL, MEDLINE, Embase, CINAHL, PsycINFO, LILACS and clinical trials registers from July 2013 to October 2017. Selection criteria: Randomised and quasi-randomised studies of rTMS, CES, tDCS, RINCE and tRNS if they employed a sham stimulation control group, recruited patients over the age of 18 years with pain of three months’ duration or more, and measured pain as an outcome. Outcomes of interest were pain intensity measured using visual analogue scales or numerical rating scales, disability, quality of life and adverse events. Data collection and analysis: Two review authors independently extracted and verified data. Where possible we entered data into meta-analyses, excluding studies judged as high risk of bias. We used the GRADE system to assess the quality of evidence for core comparisons, and created three ’Summary of findings’ tables. Main results: We included an additional 38 trials (involving 1225 randomised participants) in this update, making a total of 94 trials in the review (involving 2983 randomised participants). This update included a total of 42 rTMS studies, 11 CES, 36 tDCS, two RINCE and two tRNS. One study evaluated both rTMS and tDCS. We judged only four studies as low risk of bias across all key criteria. Using the GRADE criteria we judged the quality of evidence for each outcome, and for all comparisons as low or very low; in large part this was due to issues of blinding and of precision. rTMS: Meta-analysis of rTMS studies versus sham for pain intensity at short-term follow-up (0 to \u3c 1 week postintervention), (27 studies, involving 655 participants), demonstrated a small effect with heterogeneity (standardised mean difference (SMD) -0.22, 95% confidence interval (CI) -0.29 to -0.16, low-quality evidence). This equates to a 7% (95% CI 5% to 9%) reduction in pain, or a 0.40 (95% CI 0.53 to 0.32) point reduction on a 0 to 10 pain intensity scale, which does not meet the minimum clinically important difference threshold of 15% or greater. Pre-specified subgroup analyses did not find a difference between low-frequency stimulation (low-quality evidence) and rTMS applied to the prefrontal cortex compared to sham for reducing pain intensity at short-term follow-up (very low-quality evidence). High-frequency stimulation of the motor cortex in single-dose studies was associated with a small short-term reduction in pain intensity at short-term follow-up (low-quality evidence, pooled n = 249, SMD -0.38 95% CI -0.49 to -0.27). This equates to a 12% (95% CI 9% to 16%) reduction in pain, or a 0.77 (95% CI 0.55 to 0.99) point change on a 0 to 10 pain intensity scale, which does not achieve the minimum clinically important difference threshold of 15% or greater. The results from multiple-dose studies were heterogeneous and there was no evidence of an effect in this subgroup (very low-quality evidence). We did not find evidence that rTMS improved disability. Meta-analysis of studies of rTMS versus sham for quality of life (measured using the Fibromyalgia Impact Questionnaire (FIQ) at short-term follow-up demonstrated a positive effect (MD -10.80 95% CI -15.04 to -6.55, low-quality evidence). CES: For CES (five studies, 270 participants) we found no evidence of a difference between active stimulation and sham (SMD -0.24, 95% CI -0.48 to 0.01, low-quality evidence) for pain intensity. We found no evidence relating to the effectiveness of CES on disability. One study (36 participants) of CES versus sham for quality of life (measured using the FIQ) at short-term follow-up demonstrated a positive effect (MD -25.05 95% CI -37.82 to -12.28, very low-quality evidence). tDCS: Analysis of tDCS studies (27 studies, 747 participants) showed heterogeneity and a difference between active and sham stimulation (SMD -0.43 95% CI -0.63 to -0.22, very low-quality evidence) for pain intensity. This equates to a reduction of 0.82 (95% CI 0.42 to 1.2) points, or a percentage change of 17% (95% CI 9% to 25%) of the control group outcome. This point estimate meets our threshold for a minimum clinically important difference, though the lower confidence interval is substantially below that threshold. We found evidence of small study bias in the tDCS analyses. We did not find evidence that tDCS improved disability. Meta-analysis of studies of tDCS versus sham for quality of life (measured using different scales across studies) at short-term follow-up demonstrated a positive effect (SMD 0.66 95% CI 0.21 to 1.11, low-quality evidence). Adverse events: All forms of non-invasive brain stimulation and sham stimulation appear to be frequently associated with minor or transient side effects and there were two reported incidences of seizure, both related to the active rTMS intervention in the included studies. However many studies did not adequately report adverse events. Authors’ conclusions: There is very low-quality evidence that single doses of high-frequency rTMS of the motor cortex and tDCS may have short-term effects on chronic pain and quality of life but multiple sources of bias exist that may have influenced the observed effects. We did not find evidence that low-frequency rTMS, rTMS applied to the dorsolateral prefrontal cortex and CES are effective for reducing pain intensity in chronic pain. The broad conclusions of this review have not changed substantially for this update. There remains a need for substantially larger, rigorously designed studies, particularly of longer courses of stimulation. Future evidence may substantially impact upon the presented results

    Remote sensing: Physical principles, sensors and products, and the LANDSAT

    Get PDF
    Techniques of data acquisition by remote sensing are introduced in this teaching aid. The properties of the elements involved (radiant energy, topograph, atmospheric attenuation, surfaces, and sensors) are covered. Radiometers, photography, scanners, and radar are described as well as their products. Aspects of the LANDSAT system examined include the characteristics of the satellite and its orbit, the multispectral band scanner, and the return beam vidicon. Pixels (picture elements), pattern registration, and the characteristics, reception, and processing of LANDSAT imagery are also considered

    Estimating brain volume loss after radiation therapy in children treated for posterior fossa tumors (Corpus callosum and whole brain volume changes following radiotherapy in children).

    Get PDF
    Background More than half of pediatric tumors of central nervous system (CNS) primarily originate in the posterior fossa and are conventionally treated with radiation therapy (RT).Objectives The objective of this study was to establish whether corpus callosum volumes (CCV) and whole brain volumes (WBV) are correlated and to determine the impact of whole-brain lowvs high-dose RT on brain parenchymal volume loss as assessed using each technique.Material and methods Of the 30 identified children (6-12 years) with newly diagnosed posterior fossa tumors treated with cranial RT, including focal and whole-brain RT, suitable imaging was obtained for 23. Radiotherapy regimens were the following: no whole-brain RT (Group 1, n = 7), low-dose whole-brain RT (30 Gy, Group 3, n = 7) in addition to focal boost. Magnetic resonance images (MRIs) were analyzed at baseline and follow-up (median 14 months). The CCVs were manually segmented on midline sagittal slice (n = 23), while WBVs were segmented semi-automatically using Freesurfer (n = 15). This was done twice (6-month interval) for all baseline CCV measurements and 5 randomly selected WBV measurements to establish measurement reproducibility. Correlations between CCV and WBV were investigated and percentage of children demonstrating reduction in CCV or WBV noted.Results Correlation between baseline CCV and WBV was not significant (p = 0.37). Measurement reproducibility was from 6% to -9% for CCV and from 4.8% to -1.2% for WBV. Among the children studied, 30.4% (7/23) had >9% reduction in CCV at follow-up, while 33.3% (5/15) had >1.2% reduction in WBV. Five of 7 patients with CCV loss were not picked up by WBV measurements. Similarly, 3 of 5 patients with WBV loss were not picked up by CCV measurements.Conclusions The CCV and the WBV are unrelated and may indicate different brain parenchymal losses following RT. Up to a third of posterior fossa tumors treated with RT have measurable CCV or WBV loss; incidence was equivalent in lowvs high-dose whole-brain RT

    ESR Statement on the Validation of Imaging Biomarkers

    Get PDF
    Medical imaging capable of generating imaging biomarkers, specifically radiology and nuclear medicine image acquisition and analysis processes, differs from frequently used comparators like blood or urine biomarkers. This difference arises from the sample acquisition methodology. While different analysis methodologies and equipment provide slightly different results in any analytical domain, unlike blood or urine analysis where the samples are obtained by simple extraction or excretion, in radiology the acquisition of the sample is heterogeneous by design, since complex equipment from different vendors is used. Therefore, with this additional degree of freedom in medical imaging, there is still risk of persistent heterogeneity of image quality through time, due to different technological implementations across vendors and protocols used in different centres. Quantitative imaging biomarkers have yet to demonstrate an impact on clinical practice due to this lack of comprehensive standardisation in terms of technical aspects of image acquisition, analysis algorithms, processes and clinical validation. The aim is establishing a standard methodology based on metrology for the validation of image acquisition and analysis methods used in the extraction of biomarkers and radiomics data. The appropriate implementation of the guidelines herein proposed by radiology departments, research institutes and industry will allow for a significant reduction in inter-vendor & inter-centre variability in imaging biomarkers and determine the measurement error obtained, enabling them to be used in imaging-based criteria for diagnosis, prognosis or treatment response, ultimately improving clinical workflows and patient care. The validation of developed analytical methods must be based on a technical performance validation and clinical validation

    Implementing peer review at an emergency medicine blog: bridging the gap between educators and clinical experts

    Get PDF
    ABSTRACTEmergency physicians are leaders in the "free open-access meducation" (FOAM) movement. The mandate of FOAM is to create open-access education and knowledge translation resources for trainees and practicing physicians (e.g., blogs, podcasts, and vodcasts). Critics of FOAM have suggested that because such resources can be easily published online without quality control mechanisms, unreviewed FOAM resources may be erroneous or biased. We present a new initiative to incorporate open, expert, peer review into an established academic medical blog. Experts provided either pre- or postpublication reviews that were visible to blog readers. This article outlines the details of this initiative and discusses the potentially transformative impact of this educational innovation

    Aging and Endothelial Progenitor Cell Telomere Length in Healthy Men

    Get PDF
    BACKGROUND: Telomere length declines with age in mature endothelial cells and is thought to contribute to endothelial dysfunction and atherogenesis. Bone marrow-derived circulating endothelial progenitor cells (EPCs) are critical to vascular health as they contribute to both reendothelialization and neovascularization. We tested the hypothesis that EPC telomere length decreases with age in healthy adult humans.METHODS: Peripheral blood samples were collected from 40 healthy, non-obese, sedentary men: 12 young (age 21-34 years), 12 middle-aged (43-55 years) and 16 older (57-68 years). Putative EPCs were isolated from peripheral blood mononuclear cells and telomere length was determined using genomic DNA preparation and Southern hybridization techniques.RESULTS: EPC telomere length (base pairs) was approximately 20% (p=0.01) lower in the older (8492+523 bp) compared to the middle-aged (10,565+572 bp) and young (10,205+501 bp) men. Of note, there was no difference in EPC telomere length between the middle-aged and young men.CONCLUSIONS: These results demonstrate that EPC telomere length declines with age in healthy, sedentary men. Interestingly, telomere length was well preserved in the middle-aged compared to young men, suggesting that EPC telomere shortening occurs after the age of 55 years

    Aging and Endothelial Progenitor Cell Telomere Length in Healthy Men

    Get PDF
    BACKGROUND: Telomere length declines with age in mature endothelial cells and is thought to contribute to endothelial dysfunction and atherogenesis. Bone marrow-derived circulating endothelial progenitor cells (EPCs) are critical to vascular health as they contribute to both reendothelialization and neovascularization. We tested the hypothesis that EPC telomere length decreases with age in healthy adult humans. METHODS: Peripheral blood samples were collected from 40 healthy, non-obese, sedentary men: 12 young (age 21-34 years), 12 middle-aged (43-55 years) and 16 older (57-68 years). Putative EPCs were isolated from peripheral blood mononuclear cells and telomere length was determined using genomic DNA preparation and Southern hybridization techniques. RESULTS: EPC telomere length (base pairs) was approximately 20% (p=0.01) lower in the older (8492+523 bp) compared to the middle-aged (10,565+572 bp) and young (10,205+501 bp) men. Of note, there was no difference in EPC telomere length between the middle-aged and young men. CONCLUSIONS: These results demonstrate that EPC telomere length declines with age in healthy, sedentary men. Interestingly, telomere length was well preserved in the middle-aged compared to young men, suggesting that EPC telomere shortening occurs after the age of 55 years
    • …
    corecore