25 research outputs found
Cold performance tests of blocked-impurity-band Si:As detectors developed for DARWIN
We report first results of laboratory tests of Si:As blocked-impurity-band
(BIB) mid-infrared (4 to 28 um) detectors developed by IMEC. These prototypes
feature 88 pixels hybridized on an integrated cryogenic readout electronics
(CRE). They were developed as part of a technology demonstration program for
the future DARWIN mission. In order to be able to separate detector and readout
effects, a custom build TIA circuitry was used to characterize additional
single pixel detectors. We used a newly designed test setup at the MPIA to
determine the relative spectral response, the quantum efficiency, and the dark
current. All these properties were measured as a function of operating
temperature and detector bias. In addition the effects of ionizing radiation on
the detector were studied. For determining the relative spectral response we
used a dual-grating monochromator and a bolometer with known response that was
operated in parallel to the Si:As detectors. The quantum efficiency was
measured by using a custom-build high-precision vacuum black body together with
cold (T ~ 4 K) filters of known (measured) transmission.Comment: 11 pages, 8 figures, to appear in "High Energy, Optical, and Infrared
Detectors for Astronomy" SPIE conference Proc. 7021, Marseille, 23-28 June
200
De-escalation of axillary treatment in the event of a positive sentinel lymph node biopsy in cT1-2 N0 breast cancer treated with mastectomy:nationwide registry study (BOOG 2013-07)
Background: Trials have demonstrated the safety of omitting completion axillary lymph node dissection in patients with cT1-2 N0 breast cancer operated with breast-conserving surgery who have limited metastatic burden in the sentinel lymph node. The aim of this registry study was to provide insight into the oncological safety of omitting completion axillary treatment in patients operated with mastectomy who have limited-volume sentinel lymph node metastasis. Methods: Women diagnosed in 2013-2014 with unilateral cT1-2 N0 breast cancer treated with mastectomy, with one to three sentinel lymph node metastases (pN1mi-pN1a), were identified from the Netherlands Cancer Registry, and classified by axillary treatment: no completion axillary treatment, completion axillary lymph node dissection, regional radiotherapy, or completion axillary lymph node dissection followed by regional radiotherapy. The primary endpoint was 5-year regional recurrence rate. Secondary endpoints included recurrence-free interval and overall survival, among others. Results: In total, 1090 patients were included (no completion axillary treatment, 219 (20.1%); completion axillary lymph node dissection, 437 (40.1%); regional radiotherapy, 327 (30.0%); completion axillary lymph node dissection and regional radiotherapy, 107 (9.8%)). Patients in the group without completion axillary treatment had more favourable tumour characteristics and were older. The overall 5-year regional recurrence rate was 1.3%, and did not differ significantly between the groups. The recurrence-free interval was also comparable among groups. The group of patients who did not undergo completion axillary treatment had statistically significantly worse 5-year overall survival, owing to a higher percentage of non-cancer deaths. Conclusion:In this registry study of patients with cT1-2 N0 breast cancer treated with mastectomy, with low-volume sentinel lymph node metastasis, the 5-year regional recurrence rate was low and comparable between patients with and without completion axillary treatment.</p
De-escalation of axillary treatment in the event of a positive sentinel lymph node biopsy in cT1-2 N0 breast cancer treated with mastectomy:nationwide registry study (BOOG 2013-07)
Background: Trials have demonstrated the safety of omitting completion axillary lymph node dissection in patients with cT1-2 N0 breast cancer operated with breast-conserving surgery who have limited metastatic burden in the sentinel lymph node. The aim of this registry study was to provide insight into the oncological safety of omitting completion axillary treatment in patients operated with mastectomy who have limited-volume sentinel lymph node metastasis. Methods: Women diagnosed in 2013-2014 with unilateral cT1-2 N0 breast cancer treated with mastectomy, with one to three sentinel lymph node metastases (pN1mi-pN1a), were identified from the Netherlands Cancer Registry, and classified by axillary treatment: no completion axillary treatment, completion axillary lymph node dissection, regional radiotherapy, or completion axillary lymph node dissection followed by regional radiotherapy. The primary endpoint was 5-year regional recurrence rate. Secondary endpoints included recurrence-free interval and overall survival, among others. Results: In total, 1090 patients were included (no completion axillary treatment, 219 (20.1%); completion axillary lymph node dissection, 437 (40.1%); regional radiotherapy, 327 (30.0%); completion axillary lymph node dissection and regional radiotherapy, 107 (9.8%)). Patients in the group without completion axillary treatment had more favourable tumour characteristics and were older. The overall 5-year regional recurrence rate was 1.3%, and did not differ significantly between the groups. The recurrence-free interval was also comparable among groups. The group of patients who did not undergo completion axillary treatment had statistically significantly worse 5-year overall survival, owing to a higher percentage of non-cancer deaths. Conclusion:In this registry study of patients with cT1-2 N0 breast cancer treated with mastectomy, with low-volume sentinel lymph node metastasis, the 5-year regional recurrence rate was low and comparable between patients with and without completion axillary treatment.</p
Extracellular matrix defects in aneurysmal Fibulin-4 mice predispose to lung emphysema
Background: In this study we set out to investigate the clinically observed relationship between chronic obstructive pulmonary disease (COPD) and aortic aneurysms. We tested the hypothesis that an
An Integration Time Prediction Based Algorithm for Wide Dynamic Range 3D-Stacked Image Sensors
status: publishe
Development of Gated Pinned Avalanche Photodiode Pixels for High-Speed Low-Light Imaging
This work explores the benefits of linear-mode avalanche photodiodes (APDs) in high-speed CMOS imaging as compared to different approaches present in literature. Analysis of APDs biased below their breakdown voltage employed in single-photon counting mode is also discussed, showing a potentially interesting alternative to existing Geiger-mode APDs. An overview of the recently presented gated pinned avalanche photodiode pixel concept is provided, as well as the first experimental results on a 8 × 16 pixel test array. Full feasibility of the proposed pixel concept is not demonstrated; however, informative data is obtained from the sensor operating under −32 V substrate bias and clearly exhibiting wavelength-dependent gain in frontside illumination. The readout of the chip designed in standard 130 nm CMOS technology shows no dependence on the high-voltage bias. Readout noise level of 15 e - rms, full well capacity of 8000 e - , and the conversion gain of 75 µV / e - are extracted from the photon-transfer measurements. The gain characteristics of the avalanche junction are characterized on separate test diodes showing a multiplication factor of 1.6 for red light in frontside illumination
Model selection in electromagnetic source analysis with an application to VEF’s
Abstract — In electromagnetic source analysis it is necessary to determine how many sources are required to describe the EEG or MEG adequately. Model selection procedures (MSP’s, or goodness of fit procedures) give an estimate of the required number of sources. Existing and new MSP’s are evaluated in different source and noise settings: two sources which are close or distant, and noise which is uncorrelated or correlated. The commonly used MSP residual variance is seen to be ineffective, that is it often selects too many sources. Alternatives like the adjusted Hotelling’s test, Bayes information criterion, and the Wald test on source amplitudes are seen to be effective. The adjusted Hotelling’s test is recommended if a conservative approach is taken, and MSP’s such as Bayes information criterion or the Wald test on source amplitudes are recommended if a more liberal approach is desirable. The MSP’s are applied to empirical data (visual evoked fields). I