468 research outputs found

    Skin blood flow changes during apneic spells in preterm infants

    Get PDF
    Changes in skin blood flow during apneic spells were determined in 18 preterm infants using a diode laser Doppler flow meter without light conducting fibres. Heart rate, nasal air flow, impedance pneumography, skin and incubator temperature and laser Doppler skin blood flow were recorded simultaneously in each infant. During 212 apneic spells with a duration of 11.6 ± 7.5 s (mean ± S.D.) (range 6.0–48.0 s), the laser Doppler skin blood flow was measured. In all children except one, the majority of the apneic spells was associated with a decrease in skin blood flow. During 155 apneic spells (73%) skin blood flow decreased significantly P < 0.025), the maximum decrease being 16.7 ± 14.8%, 28.5 ± 23.9% and 18.9 ± 16.1% (mean ± S.D.) for central, obstructive and mixed apneic spells, respectively. The decrease in skin blood flow started immediately after the beginning of apneic spells in 71%, the rest started with a mean delay of 3.4 s (range 0.1–7.0 s). No relation was found between the decrease in skin blood flow and the duration of the apneic spells. Thirty-four percent of the apneic spells were accompanied by bradycardia. In apneic spells accompanied by bradycardia the decrease in skin blood flow was not related to the fall in heart rate

    Two small-volume electrochemical cells for the measurement of surface enhanced Raman scattering

    Get PDF
    Two electrochemical cells, for performing surface enhanced Raman scattering (SERS), with submillilitre volumes are presented. One of the cells is especially developed for use in a Raman microspectrometer. The smallest cell uses only 80 mu l of sample. SER measurements are performed on 2*10-3 M adenine

    A high‐throughput Raman notch filter set

    Get PDF
    A chevron‐type Raman notch filter (RNF) set is described. lt combines a high signal throughput (up to 90% around 1600 cm−1 and ≳80% between and 700 and 2700 cm−1) with a laser line suppression of 108–109. The filter set can be used to replace the first two dispersion stages in triple‐stage Raman monochromators commonly employed in multichannel detection systems. This yields a gain in intensity of the detected Raman signal of a factor of 4. It is shown that in Raman spectrometers with a backscatter geometry, the filter set can also be used to optically couple the microscope and the spectrometer. This leads to a further increase in signal intensity of a factor of 3–4 as compared to the situation where a beam splitter is used. Additional advantages of the RNF set are the fact that signal throughput is almost polarization independent over a large spectral interval and that it offers the possibility to simultaneously record Stokes and anti‐Stokes spectra

    Inname aan zware metalen en nitraat door jonge kinderen

    Get PDF
    Innameberekeningen zijn uitgevoerd voor zware metalen, nitraat en zout op basis van metingen uit een duplicaat voedingsstudie bij baby's en deze zijn vergeleken met innameberekeningen op basis van monitoringsdata uit de KAP-databank. Voor de duplicaat voedingen is gebruik gemaakt van data verzameld in de EUBABY-studie van baby’s van 8 tot 12 maande
    corecore