7,507 research outputs found
Role of substrate induced electron–phonon interactions in biased graphitic bilayers
Bilayers of graphitic materials have potential applications in field effect transistors (FETs). A potential difference applied between certain ionic bilayers made from insulating graphitic materials such as BN, ZnO and AlN could reduce gap sizes, turning them into useful semiconductors. On the other hand, opening of a small semiconducting gap occurs in graphene bilayers under applied field. The aim here is to investigate to what extent substrate induced electron–phonon interactions (EPIs) modify this gap change. We examine EPIs in several lattice configurations of graphitic bilayers, using a perturbative approach. The typical effect of EPIs on the ionic bilayers is an undesirable gap widening. The size of this gap change varies considerably with lattice structure and the magnitude of the bias. When bias is larger than the non-interacting gap size, EPIs have the smallest effect on the bandgap, especially in configurations with and structures. Thus careful selection of substrate, lattice configuration and bias strength to minimise the effects of EPIs could be important for optimising the properties of electronic devices. We use parameters related to BN in this article. In practice, the results presented here are broadly applicable to other graphitic bilayers, and are likely to be qualitatively similar in metal dichalcogenide bilayers such as MoS2, which are already of high interest for their use in FETs
A nullstellensatz for sequences over F_p
Let p be a prime and let A=(a_1,...,a_l) be a sequence of nonzero elements in
F_p. In this paper, we study the set of all 0-1 solutions to the equation a_1
x_1 + ... + a_l x_l = 0. We prove that whenever l >= p, this set actually
characterizes A up to a nonzero multiplicative constant, which is no longer
true for l < p. The critical case l=p is of particular interest. In this
context, we prove that whenever l=p and A is nonconstant, the above equation
has at least p-1 minimal 0-1 solutions, thus refining a theorem of Olson. The
subcritical case l=p-1 is studied in detail also. Our approach is algebraic in
nature and relies on the Combinatorial Nullstellensatz as well as on a Vosper
type theorem.Comment: 23 page
Open circular billiards and the Riemann hypothesis
A comparison of escape rates from one and from two holes in an experimental
container (e.g. a laser trap) can be used to obtain information about the
dynamics inside the container. If this dynamics is simple enough one can hope
to obtain exact formulas. Here we obtain exact formulas for escape from a
circular billiard with one and with two holes. The corresponding quantities are
expressed as sums over zeroes of the Riemann zeta function. Thus we demonstrate
a direct connection between recent experiments and a major unsolved problem in
mathematics, the Riemann hypothesis.Comment: 5 pages, 4 embedded postscript figures; v2: more explicit on how the
Reimann Hypothesis arises from a comparison of one and two hole escape rate
Heavy metal toxicity as a kill mechanism in impact caused mass extinctions
Heavy metals that are known to be toxic exist in carbonaceous chrondrites at abundances considerably in excess to that of the terrestrial crust. An impactor of relatively undifferentiated cosmic matter would inject into the terrestrial environment large quantities of toxic elements. The abundances of toxic metals found in the Allende CV carbonaceous chondrite and the ratio of meteoritic abundance to crustal abundance are: Cr, 3630 PPM, 30X; Co, 662 PPM, 23X; ni, 13300 PPm, 134X; se, 8.2 PPM, 164X; Os, 0.828 PPM, 166X. The resulting areal density for global dispersal of impactor derived heavy metals and their dilution with terrestrial ejecta are important factors in the determination of the significance of impactor heavy metal toxicity as a kill mechanism in impact caused mass extinctions. A 10 km-diameter asteroid having a density of 3 gram per cu cm would yield a global areal density of impact dispersed chondritic material of 3 kg per square meter. The present areal density of living matter on the terrestrial land surface is 1 kg per square meter. Dilution of impactor material with terrestrial ejecta is determined by energetics, with the mass of ejecta estimated to be in the range of 10 to 100 times that of the mass of the impactor. Because a pelagic impact would be the most likely case, the result would be a heavy metal rainout
Evaluating PET-CT in the detection and management of recurrent cervical cancer: Systematic reviews of diagnostic accuracy and subjective elicitation
Background: Positron emission tomography-computed tomography (PET-CT) is recommended to triage women for exenterative surgery and surveillance after treatment for advanced cervical cancer. Objective: To evaluate diagnostic accuracy of additional whole body PET-CT compared with CT/magnetic resonance imaging (MRI) alone in women with suspected recurrent/persistent cervical cancer and in asymptomatic women as surveillance. Design: Systematic reviews. Subjective elicitation to supplement diagnostic information. Search strategy/Selection criteria/Data collection and analysis: Searches of electronic databases were performed to June 2013. Studies in women with suspected recurrent/persistent cervical cancer and in asymptomatic women undergoing follow up with sufficient numeric data were included. We calculated sensitivity, specificity and corresponding 95% confidence intervals. Meta-analyses employed a bivariate model that included a random-effects term for between-study variations (CT studies) and univariate random effects meta-analyses (PET-CT studies) for sensitivity and specificity separately. Subjective elicitation: Prevalence of recurrence and the accuracy of imaging elicited using the allocation of points technique. Coherence of elicited subjective probabilities with estimates in the literature examined. Results: We identified 15 relevant studies; none directly compared additional PET-CT with MRI or CT separately. Most CT and MRI studies used older protocols and the majority did not distinguish between asymptomatic and symptomatic women. Meta-analysis of nine PET-CT studies in mostly symptomatic women showed sensitivity of 94.8 (95% CI 91.2-96.9), and specificity of 86.9% (95% CI 82.2-90.5). The summary estimate of the sensitivity of CT for detection of recurrence was 89.64% (95% CI 81.59-94.41) and specificity was 76% (95% CI 43.68-92.82). Meta-analysis for MRI test accuracy studies was not possible because of clinical heterogeneity. The sensitivity and specificity of MRI in pelvic recurrence varied between 82 and 100% and between 78 and 100%, respectively. Formal statistical comparisons of the accuracy of index tests were not possible. Subjective elicitation provided estimates comparable to the literature. Subjective estimates of the increase in accuracy from the addition of PET-CT were less than elicited increases required to justify the use in PET-CT for surveillance. Conclusion: Evidence to support additional PET-CT is scarce, of average quality and does not distinguish between application for surveillance and diagnosis. Guidelines recommending PET-CT in recurrent cervical cancer need to be reconsidered in the light of the existing evidence base
Recommended from our members
Method for producing angled optical fiber tips in the laboratory
A simple laboratory method is presented for producing optical fibers with tips polished at various angles. Angled optical fiber tips are used in applications such as optical sensing and remote laser surgery, where they can be used to control the angle of light leaving the fiber or direct it to the side. This allows for greater control and allows areas to be reached that otherwise could not. Optical fibers were produced with tip angles of 45 deg using a Perspex mounting block with an aluminum base plate. The dispersion of light leaving the tip was tested using a blue (470 nm) LED. The angle imposed an angular shift on the light diffracting out of the tip of approximately 30 deg. Additionally, some light reflected from the tip surface to diffract at 90 deg through the side of the fiber. These observations are consistent with theory and those seen by other studies, validating the method. The method was simple to perform and does not require advanced manufacturing tools. The method is suitable for producing small quantities of angle-tipped optical fibers for research applications
Recommended from our members
Fiber-optic fluorescence-quenching oxygen partial pressure sensor using platinum octaethylporphyrin
The development and bench testing of a fiber-optic oxygen sensor is described. The sensor is designed for measurement of tissue oxygen levels in the mucosa of the digestive tract. The materials and construction are optimized for insertion through the mouth for measurement in the lower esophagus. An oxygen-sensitive fluorescence-quenching film was applied as a solution of platinum octaethylporphyrin (PtOEP) poly(ethyl methacrylate) (PEMA) and dichloromethane and dip coated onto the distal tip of the fiber. The sensor was tested by comparing relative fluorescence when immersed in liquid water at 37°C, at a range of partial pressures (0–101 kPa). Maximum relative fluorescence at most oxygen concentrations was seen when the PtOEP concentration was 0.1  g.L−10.1  g.L−1, four layers of coating solution were applied, and a fiber core radius of 600 μm was selected, giving a Stern–Volmer constant of 0.129  kPa−10.129  kPa−1. The performance of the sensor is suitable for many in vivo applications, particularly mucosal measurements. It has sufficient sensitivity, is sterilizable, and is sufficiently flexible and robust for insertion via the mouth without damage to the probe or risk of harm to the patient
The current progress of the ALICE Ring Imaging Cherenkov Detector
Recently, the last two modules (out of seven) of the ALICE High Momentum
Particle Identification detector (HMPID) were assembled and tested. The full
detector, after a pre-commissioning phase, has been installed in the
experimental area, inside the ALICE solenoid, at the end of September 2006. In
this paper we review the status of the ALICE/HMPID project and we present a
summary of the series production of the CsI photo-cathodes. We describe the key
features of the production procedure which ensures high quality photo-cathodes
as well as the results of the quality assessment performed by means of a
specially developed 2D scanner system able to produce a detailed map of the CsI
photo-current over the entire photo-cathode surface.
Finally we present our recent R&D efforts toward the development of a novel
generation of imaging Cherenkov detectors with the aim to identify, in heavy
ions collisions, hadrons up to 30 GeV/c.Comment: Presented at the Imaging-2006 Conference, Stockholm, Sweden, June
200
- …