12 research outputs found

    Mean range bunching of exotic nuclei produced by in-flight fragmentation and fission — Stopped-beam experiments with increased efficiency

    Get PDF
    The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-filled stopping cell or an implantation detector. Stopping and studying a cocktail beam overcomes the present limitations of stopped-beam experiments. The conceptual idea of mean range bunching is described and illustrated using simulations. In a single setting of the FRS, 37 different nuclides were stopped in the cryogenic stopping cell and were measured in a single setting broadband mass measurement with the multiple-reflection time-of-flight mass spectrometer of the FRS Ion Catcher.</p

    Depth dose measurements in water for 11C and 10C beams with therapy relevant energies

    Get PDF
    Owing to the favorable depth-dose distribution and the radiobiological properties of heavy ion radiation, ion beam therapy shows an improved success/toxicity ratio compared to conventional radiotherapy. The sharp dose gradients and very high doses in the Bragg peak region, which represent the larger physical advantage of ion beam therapy, make it also extremely sensitive to range uncertainties. The use of beta(+) - radioactive ion beams would be ideal for simultaneous treatment and accurate online range monitoring through PET imaging. Since all the unfragmented primary ions are potentially contributing to the PET signal, these beams offer an improved image quality while preserving the physical and radiobiological advantages of the stable counterparts. The challenging production of radioactive ion beams and the difficulties in reaching high intensities, have discouraged their clinical application. In this context, the project Biomedical Applications of Radioactive ion Beams (BARB) started at GSI (Helmholtzzentrum fur Schwerionenforschung GmbH) with the main goal to assess the technical feasibility and investigate possible advantages of radioactive ion beams on the pre-clinical level. During the first experimental campaign C-11 and C-10 beams were produced and isotopically separated with the FRagment Separator (FRS) at GSI. The beta(+)-radioactive ion beams were produced with a beam purity of 99% for all the beam investigated (except one case where it was 94%) and intensities potentially sufficient to treat a small animal tumors within few minutes of irradiation time, similar to 10(6) particle per spill for the C-10 and similar to 10(7) particle per spill for the C-11 beam, respectively. The impact of different ion optical parameters on the depth dose distribution was studied with a precision water column system. In this work, the measured depth dose distributions are presented together with results from Monte Carlo simulations using the FLUKA software

    Mean range bunching of exotic nuclei produced by in-flight fragmentation and fission — Stopped-beam experiments with increased efficiency

    Get PDF
    The novel technique of mean range bunching has been developed and applied at the projectile fragment separator FRS at GSI in four experiments of the FAIR phase-0 experimental program. Using a variable degrader system at the final focal plane of the FRS, the ranges of the different nuclides can be aligned, allowing to efficiently implant a large number of different nuclides simultaneously in a gas-filled stopping cell or an implantation detector. Stopping and studying a cocktail beam overcomes the present limitations of stopped-beam experiments. The conceptual idea of mean range bunching is described and illustrated using simulations. In a single setting of the FRS, 37 different nuclides were stopped in the cryogenic stopping cell and were measured in a single setting broadband mass measurement with the multiple-reflection time-of-flight mass spectrometer of the FRS Ion Catcher.</p

    Mass tagging:Verification and calibration of particle identification by high-resolution mass measurements

    Get PDF
    The access to exotic nuclei at radioactive ion beam facilities is crucial for the state of the art research across several fields of physics such as in nuclear structure, the understanding of fundamental interactions and nuclear astrophysics. The particle identification is of high importance, besides the challenging production of these rare and short-lived nuclei. At in-flight facilities, the particle identification is based on measuring the time-of-flight, energy-deposition and magnetic rigidity. These quantities are calibrated to convert them into A/Q and Z of the ions. To ensure a correct calibration, the unambiguous identification, also called tagging, of one species is necessary. Here, we present a novel tagging method by high-resolution mass measurements using an MR-TOF-MS after thermalization of the ions in a cryogenic stopping cell. The method was successfully established and tested at the fragment separator FRS at GSI with the FRS Ion Catcher in experiments using different FRS operation modes.</p

    Radioactive Beams for Image-Guided Particle Therapy : The BARB Experiment at GSI

    Get PDF
    Several techniques are under development for image-guidance in particle therapy. Positron (β+) emission tomography (PET) is in use since many years, because accelerated ions generate positron-emitting isotopes by nuclear fragmentation in the human body. In heavy ion therapy, a major part of the PET signals is produced by β+-emitters generated via projectile fragmentation. A much higher intensity for the PET signal can be obtained using β+-radioactive beams directly for treatment. This idea has always been hampered by the low intensity of the secondary beams, produced by fragmentation of the primary, stable beams. With the intensity upgrade of the SIS-18 synchrotron and the isotopic separation with the fragment separator FRS in the FAIR-phase-0 in Darmstadt, it is now possible to reach radioactive ion beams with sufficient intensity to treat a tumor in small animals. This was the motivation of the BARB (Biomedical Applications of Radioactive ion Beams) experiment that is ongoing at GSI in Darmstadt. This paper will present the plans and instruments developed by the BARB collaboration for testing the use of radioactive beams in cancer therapy.peerReviewe

    Studying Gamow-Teller transitions and the assignment of isomeric and ground states at N = 50

    No full text
    Direct mass measurements of neutron-deficient nuclides around the N=50 shell closure below 100Sn were performed at the FRS Ion Catcher (FRS-IC) at GSI, Germany. The nuclei were produced by projectile fragmentation of 124Xe, separated in the fragment separator FRS and delivered to the FRS-IC. The masses of 14 ground states and two isomers were measured with relative mass uncertainties down to 1×10−7 using the multiple-reflection time-of-flight mass spectrometer of the FRS-IC, including the first direct mass measurements of 98Cd and 97Rh. A new QEC=5437±67 keV was obtained for 98Cd, resulting in a summed Gamow-Teller (GT) strength for the five observed transitions (0+⟶1+) as B(GT)=2.94−0.28+0.32. Investigation of this result in state-of-the-art shell model approaches accounting for the first time experimentally observed spectrum of GT transitions points to a perfect agreement for N=50 isotones. The excitation energy of the long-lived isomeric state in 94Rh was determined for the first time to be 293±21 keV. This, together with the shell model calculations, allows the level ordering in 94Rh to be understood

    Studying Gamow-Teller transitions and the assignment of isomeric and ground states at N=50

    Get PDF
    Direct mass measurements of neutron-deficient nuclides around the N = 50 shell closure below 100Sn were performed at the FRS Ion Catcher (FRS-IC) at GSI, Germany. The nuclei were produced by projectile fragmentation of 124Xe, separated in the fragment separator FRS and delivered to the FRS-IC. The masses of 14 ground states and two isomers were measured with relative mass uncertainties down to 1 x 10-7 using the multiple-reflection time-of-flight mass spectrometer of the FRS-IC, including the first direct mass measurements of 98Cd , 97Rh. A new QEC = 5437 +/- 67 keV was obtained for 98Cd, resulting in a summed Gamow-Teller (GT) strength for the five observed transitions (0+ --> 1+) as B(GT) = 2.94+0.32 -0.28. Investigation of this result in state-of-the-art shell model approaches accounting for the first time experimentally observed spectrum of GT transitions points to a perfect agreement for N = 50 isotones. The excitation energy of the long-lived isomeric state in 94Rh was determined for the first time to be 293 +/- 21 keV. This, together with the shell model calculations, allows the level ordering in 94Rh to be understood.(c) 2023 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons .org /licenses /by /4 .0/). Funded by SCOAP3.Peer reviewe
    corecore