    Multi-modality functional image guided dose escalation in the presence of uncertainties

    Get PDF
    AbstractBackground and purposeIn order to increase local tumour control by radiotherapy without increasing toxicity, it appears promising to harness functional imaging (FI) to guide dose to sub-volumes of the target with a high tumour load and perhaps de-escalate dose to low risk volumes, in order to maximise the efficiency of the deposited radiation dose.Methods and materialsA number of problems have to be solved to make focal dose escalation (FDE) efficient and safe: (1) how to combine ambiguous information from multiple imaging modalities; (2) how to take into account uncertainties of FI based tissue classification; (3) how to account for geometric uncertainties in treatment delivery; (4) how to add complementary FI modalities to an existing scheme. A generic optimisation concept addresses these points and is explicitly designed for clinical efficacy and for lowering the implementation threshold to FI-guided FDE. It combines classic tumour control probability modelling with a multi-variate logistic regression model of FI accuracy and an uncomplicated robust optimisation method.ResultsIts key elements are (1) that dose is deposited optimally when it achieves equivalent expected effect everywhere in the target volume and (2) that one needs to cap the certainty about the absence of tumour anywhere in the target region. For illustration, an example of a PET/MR-guided FDE in prostate cancer is given.ConclusionsFDE can be safeguarded against FI uncertainties, at the price of a limit on the sensible dose escalation

    Rationale for Combining Radiotherapy and Immune Checkpoint Inhibition for Patients With Hypoxic Tumors

    Get PDF
    In order to compensate for the increased oxygen consumption in growing tumors, tumors need angiogenesis and vasculogenesis to increase the supply. Insufficiency in this process or in the microcirculation leads to hypoxic tumor areas with a significantly reduced pO2, which in turn leads to alterations in the biology of cancer cells as well as in the tumor microenvironment. Cancer cells develop more aggressive phenotypes, stem cell features and are more prone to metastasis formation and migration. In addition, intratumoral hypoxia confers therapy resistance, specifically radioresistance. Reactive oxygen species are crucial in fixing DNA breaks after ionizing radiation. Thus, hypoxic tumor cells show a two- to threefold increase in radioresistance. The microenvironment is enriched with chemokines (e.g., SDF-1) and growth factors (e.g., TGFβ) additionally reducing radiosensitivity. During recent years hypoxia has also been identified as a major factor for immune suppression in the tumor microenvironment. Hypoxic tumors show increased numbers of myeloid derived suppressor cells (MDSCs) as well as regulatory T cells (Tregs) and decreased infiltration and activation of cytotoxic T cells. The combination of radiotherapy with immune checkpoint inhibition is on the rise in the treatment of metastatic cancer patients, but is also tested in multiple curative treatment settings. There is a strong rationale for synergistic effects, such as increased T cell infiltration in irradiated tumors and mitigation of radiation-induced immunosuppressive mechanisms such as PD-L1 upregulation by immune checkpoint inhibition. Given the worse prognosis of patients with hypoxic tumors due to local therapy resistance but also increased rate of distant metastases and the strong immune suppression induced by hypoxia, we hypothesize that the subgroup of patients with hypoxic tumors might be of special interest for combining immune checkpoint inhibition with radiotherapy

    Multiple training interventions significantly improve reproducibility of PET/CT-based lung cancer radiotherapy target volume delineation using an IAEA study protocol

    Get PDF
    AbstractBackground and purposeTo assess the impact of a standardized delineation protocol and training interventions on PET/CT-based target volume delineation (TVD) in NSCLC in a multicenter setting.Material and methodsOver a one-year period, 11 pairs, comprised each of a radiation oncologist and nuclear medicine physician with limited experience in PET/CT-based TVD for NSCLC from nine different countries took part in a training program through an International Atomic Energy Agency (IAEA) study (NCT02247713). Teams delineated gross tumor volume of the primary tumor, during and after training interventions, according to a provided delineation protocol. In-house developed software recorded the performed delineations, to allow visual inspection of strategies and to assess delineation accuracy.ResultsFollowing the first training, overall concordance indices for 3 repetitive cases increased from 0.57±0.07 to 0.66±0.07. The overall mean surface distance between observer and expert contours decreased from −0.40±0.03cm to −0.01±0.33cm. After further training overall concordance indices for another 3 repetitive cases further increased from 0.64±0.06 to 0.80±0.05 (p=0.01). Mean surface distances decreased from −0.34±0.16cm to −0.05±0.20cm (p=0.01).ConclusionMultiple training interventions improve PET/CT-based TVD delineation accuracy in NSCLC and reduce interobserver variation

    Local control and patient reported outcomes after online MR guided stereotactic body radiotherapy of liver metastases

    Get PDF
    IntroductionStereotactic body radiotherapy (SBRT) is used to treat liver metastases with the intention of ablation. High local control rates were shown. Magnetic resonance imaging guided radiotherapy (MRgRT) provides the opportunity of a marker-less liver SBRT treatment due to the high soft tissue contrast. We report herein on one of the largest cohorts of patients treated with online MRgRT of liver metastases focusing on oncological outcome, toxicity, patient reported outcome measures (PROMs), quality of life.Material and methodsPatients treated for liver metastases with online MR-guided SBRT at a 1,5 T MR-Linac (Unity, Elekta, Crawley, UK) between March 2019 and December 2021 were included in this prospective study. UK SABR guidelines were used for organs at risk constraints. Oncological endpoints such as survival parameters (overall survival, progression-free survival) and local control as well as patient reported acceptance and quality of life data (EORTC QLQ-C30 questionnaire) were assessed. For toxicity scoring the Common Toxicity Criteria Version 5 were used.ResultsA total of 51 patients with 74 metastases were treated with a median of five fractions. The median applied BED GTV D98 was 84,1 Gy. Median follow-up was 15 months. Local control of the irradiated liver metastasis after 12 months was 89,6%, local control of the liver was 40,3%. Overall survival (OS) after 12 months was 85.1%. Progression free survival (PFS) after 12 months was 22,4%. Local control of the irradiated liver lesion was 100% after three years when a BED ≥100 Gy was reached. The number of treated lesions did not impact local control neither of the treated or of the hepatic control. Patient acceptance of online MRgSBRT was high. There were no acute grade ≥ 3 toxicities. Quality of life data showed no significant difference comparing baseline and follow-up data.ConclusionOnline MR guided radiotherapy is a noninvasive, well-tolerated and effective treatment for liver metastases. Further prospective trials with the goal to define patients who actually benefit most from an online adaptive workflow are currently ongoing

    Professional practice changes in radiotherapy physics during the COVID-19 pandemic.

    Get PDF
    Background and purpose The COVID-19 pandemic has imposed changes in radiotherapy (RT) departments worldwide. Medical physicists (MPs) are key healthcare professionals in maintaining safe and effective RT. This study reports on MPs experience during the first pandemic peak and explores the consequences on their work. Methods A 39-question survey on changes in departmental and clinical practice and on the impact for the future was sent to the global MP community. A total of 433 responses were analysed by professional role and by country clustered on the daily infection numbers. Results The impact of COVID-19 was bigger in countries with high daily infection rate. The majority of MPs worked in alternation at home/on-site. Among practice changes, implementation and/or increased use of hypofractionation was the most common (47% of the respondents). Sixteen percent of respondents modified patient-specific quality assurance (QA), 21% reduced machine QA, and 25% moved machine QA to weekends/evenings. The perception of trust in leadership and team unity was reversed between management MPs (towards increased trust and unity) and clinical MPs (towards a decrease). Changes such as home-working and increased use of hypofractionation were welcomed. However, some MPs were concerned about pressure to keep negative changes (e.g. weekend work). Conclusion COVID-19 affected MPs through changes in practice and QA procedures but also in terms of trust in leadership and team unity. Some changes were welcomed but others caused worries for the future. This report forms the basis, from a medical physics perspective, to evaluate long-lasting changes within a multi-disciplinary setting

    Professional quality of life and burnout amongst radiation oncologists:The impact of alexithymia and empathy

    Get PDF
    Background and purpose: Different factors may influence the professional quality of life of oncology professionals. Among them, personality traits, as alexithymia and empathy, are underinvestigated. Alexithymia is about deficits in emotion processing and awareness. Empathy is the ability to understand another's 'state of mind'/emotion. The PROject on BurnOut in RadiatioN Oncology (PRO BONO) assesses professional quality of life, including burnout, in the field of radiation oncology and investigates alexithymia and empathy as contributing factors. Material and methods: An online survey was conducted amongst ESTRO members. Participants completed 3 validated questionnaires for alexithymia, empathy and professional quality of life: (a) Toronto Alexithymia Scale; (b) Interpersonal Reactivity Index; (c) Professional Quality of Life Scale. The present analysis, focusing on radiation/clinical oncologists, evaluates Compassion Satisfaction (CS), Secondary Traumatic Stress (STS) and Burnout and correlates them with alexithymia and empathy (empathic concern, perspective taking and personal distress) with generalized linear modeling. Significant covariates on univariate linear regression analysis were included in the multivariate linear regression model. Results: A total of 825 radiation oncologists completed all questionnaires. A higher level of alexithymia was associated to decreased CS (beta:-0.101; SE: 0.018; p <0.001), increased STS (beta: 0.228; SE: 0.018; p <0.001) and burnout (beta: 0.177; SE: 0.016; p <0.001). A higher empathic concern was significantly associated to increased CS (beta: 0.1.287; SE: 0.305; p = 0.001), STS (beta: 0.114; SE: 0.296; p <0.001), with no effect on burnout. Personal distress was associated to decreased CS (beta:-1.423; SE: 0.275; p <0.001), increased STS (beta: 1.871; SE: 0.283; p <0.001) and burnout (beta: 1.504; SE: 0.245; p <0.001). Conclusions: Alexithymic personality trait increased burnout risk, with less professional satisfaction. Empathic concern was associated to increased stress, without leading to burnout, resulting in higher professional fulfillment. These results may be used to benchmark preventing strategies, such as work-hour restrictions, peer support, debriefing sessions, and leadership initiatives for professionals at risk. (c) 2020 Elsevier B.V. All rights reserved. Radiotherapy and Oncology 147 (2020) 162-16

    A multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy

    Get PDF
    Background and Purpose: Application of different deformable dose accumulation (DDA) solutions makes institutional comparisons after online-adaptive magnetic resonance-guided radiotherapy (OA-MRgRT) challenging. The aim of this multi-institutional study was to analyze accuracy and agreement of DDA-implementations in OA-MRgRT. Material and Methods: One gold standard (GS) case deformed with a biomechanical-model and five clinical cases consisting of prostate (2x), cervix, liver, and lymph node cancer, treated with OA-MRgRT, were analyzed. Six centers conducted DDA using institutional implementations. Deformable image registration (DIR) and DDA results were compared using the contour metrics Dice Similarity Coefficient (DSC), surface-DSC, Hausdorff-distance (HD95%), and accumulated dose-volume histograms (DVHs) analyzed via intraclass correlation coefficient (ICC) and clinical dosimetric criteria (CDC). Results: For the GS, median DDA errors ranged from 0.0 to 2.8 Gy across contours and implementations. DIR of clinical cases resulted in DSC > 0.8 for up to 81.3% of contours and a variability of surface-DSC values depending on the implementation. Maximum HD95%=73.3 mm was found for duodenum in the liver case. Although DVH ICC > 0.90 was found after DDA for all but two contours, relevant absolute CDC differences were observed in clinical cases: Prostate I/II showed maximum differences in bladder V28Gy (10.2/7.6%), while for cervix, liver, and lymph node the highest differences were found for rectum D2cm3 (2.8 Gy), duodenum Dmax (7.1 Gy), and rectum D0.5cm3 (4.6 Gy). Conclusion: Overall, high agreement was found between the different DIR and DDA implementations. Case- and algorithm-dependent differences were observed, leading to potentially clinically relevant results. Larger studies are needed to define future DDA-guidelines

    Prospective Evaluation of In Vivo and Phantom Repeatability and Reproducibility of Diffusion-Weighted MRI Sequences on 1.5T MRI-Linear Accelerator (MR-Linac) and MR Simulator Devices for Head and Neck Cancers

    Get PDF
    INTRODUCTION: Diffusion-weighted imaging (DWI) on MRI-linear accelerator (MR-linac) systems can potentially be used for monitoring treatment response and adaptive radiotherapy in head and neck cancers (HNC) but requires extensive validation. We performed technical validation to compare six total DWI sequences on an MR-linac and MR simulator (MR sim) in patients, volunteers, and phantoms. METHODS: Ten human papillomavirus-positive oropharyngeal cancer patients and ten healthy volunteers underwent DWI on a 1.5T MR-linac with three DWI sequences: echo planar imaging (EPI), split acquisition of fast spin echo signals (SPLICE), and turbo spin echo (TSE). Volunteers were also imaged on a 1.5T MR sim with three sequences: EPI, BLADE (vendor tradename), and readout segmentation of long variable echo trains (RESOLVE). Participants underwent two scan sessions per device and two repeats of each sequence per session. Repeatability and reproducibility within-subject coefficient of variation (wCV) of mean ADC were calculated for tumors and lymph nodes (patients) and parotid glands (volunteers). ADC bias, repeatability/reproducibility metrics, SNR, and geometric distortion were quantified using a phantom. RESULTS: In vivo repeatability/reproducibility wCV for parotids were 5.41%/6.72%, 3.83%/8.80%, 5.66%/10.03%, 3.44%/5.70%, 5.04%/5.66%, 4.23%/7.36% for EPI MR-linac, SPLICE, TSE, EPI MR sim, BLADE, RESOLVE. Repeatability/reproducibility wCV for EPI MR-linac, SPLICE, TSE were 9.64%/10.28%, 7.84%/8.96%, 7.60%/11.68% for tumors and 7.80%/9.95%, 7.23%/8.48%, 10.82%/10.44% for nodes. All sequences except TSE had phantom ADC biases within ±0.1x10 -3 mm 2/s for most vials (EPI MR-linac, SPLICE, and BLADE had 2, 3, and 1 vials out of 13 with larger biases, respectively). SNR of b=0 images was 87.3, 180.5, 161.3, 171.0, 171.9, 130.2 for EPI MR-linac, SPLICE, TSE, EPI MR sim, BLADE, RESOLVE. CONCLUSION: MR-linac DWI sequences demonstrated near-comparable performance to MR sim sequences and warrant further clinical validation for treatment response assessment in HNC

    Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation

    Get PDF
    MRI-linear accelerator (MR-linac) devices have been introduced into clinical practice in recent years and have enabled MR-guided adaptive radiation therapy (MRgART). However, by accounting for anatomical changes throughout radiation therapy (RT) and delivering different treatment plans at each fraction, adaptive radiation therapy (ART) highlights several challenges in terms of calculating the total delivered dose. Dose accumulation strategies-which typically involve deformable image registration between planning images, deformable dose mapping, and voxel-wise dose summation-can be employed for ART to estimate the delivered dose. In MRgART, plan adaptation on MRI instead of CT necessitates additional considerations in the dose accumulation process because MRI pixel values do not contain the quantitative information used for dose calculation. In this review, we discuss considerations for dose accumulation specific to MRgART and in relation to current MR-linac clinical workflows. We present a general dose accumulation framework for MRgART and discuss relevant quality assurance criteria. Finally, we highlight the clinical importance of dose accumulation in the ART era as well as the possible ways in which dose accumulation can transform clinical practice and improve our ability to deliver personalized RT
    • …