101 research outputs found

    Short-range spin glasses and Random Overlap Structures

    Full text link
    Properties of Random Overlap Structures (ROSt)'s constructed from the Edwards-Anderson (EA) Spin Glass model on Zd\Z^d with periodic boundary conditions are studied. ROSt's are N×N\N\times\N random matrices whose entries are the overlaps of spin configurations sampled from the Gibbs measure. Since the ROSt construction is the same for mean-field models (like the Sherrington-Kirkpatrick model) as for short-range ones (like the EA model), the setup is a good common ground to study the effect of dimensionality on the properties of the Gibbs measure. In this spirit, it is shown, using translation invariance, that the ROSt of the EA model possesses a local stability that is stronger than stochastic stability, a property known to hold at almost all temperatures in many spin glass models with Gaussian couplings. This fact is used to prove stochastic stability for the EA spin glass at all temperatures and for a wide range of coupling distributions. On the way, a theorem of Newman and Stein about the pure state decomposition of the EA model is recovered and extended.Comment: 27 page

    Participant recruitment and retention in a pilot program to prevent weight gain in low-income overweight and obese mothers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recruitment and retention are key functions for programs promoting nutrition and other lifestyle behavioral changes in low-income populations. This paper describes strategies for recruitment and retention and presents predictors of early (two-month post intervention) and late (eight-month post intervention) dropout (non retention) and overall retention among young, low-income overweight and obese mothers participating in a community-based randomized pilot trial called <it>Mothers In Motion</it>.</p> <p>Methods</p> <p>Low-income overweight and obese African American and white mothers ages 18 to 34 were recruited from the Special Supplemental Nutrition Program for Women, Infants, and Children in southern Michigan. Participants (n = 129) were randomly assigned to an intervention (n = 64) or control (n = 65) group according to a stratification procedure to equalize representation in two racial groups (African American and white) and three body mass index categories (25.0-29.9 kg/m<sup>2</sup>, 30.0-34.9 kg/m<sup>2</sup>, and 35.0-39.9 kg/m<sup>2</sup>). The 10-week theory-based culturally sensitive intervention focused on healthy eating, physical activity, and stress management messages that were delivered via an interactive DVD and reinforced by five peer-support group teleconferences. Forward stepwise multiple logistic regression was performed to examine whether dietary fat, fruit and vegetable intake behaviors, physical activity, perceived stress, positive and negative affect, depression, and race predicted dropout as data were collected two-month and eight-month after the active intervention phase.</p> <p>Results</p> <p>Trained personnel were successful in recruiting subjects. Increased level of depression was a predictor of early dropout (odds ratio = 1.04; 95% CI = 1.00, 1.08; p = 0.03). Greater stress predicted late dropout (odds ratio = 0.20; 95% CI = 0.00, 0.37; p = 0.01). Dietary fat, fruit, and vegetable intake behaviors, physical activity, positive and negative affect, and race were not associated with either early or late dropout. Less negative affect was a marginal predictor of participant retention (odds ratio = 0.57; 95% CI = 0.31, 1.03; p = 0.06).</p> <p>Conclusion</p> <p>Dropout rates in this study were higher for participants who reported higher levels of depression and stress.</p> <p>Trial registration</p> <p>Current Controlled Trials NCT00944060</p

    Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Even though technological progress has provided us with more and more sophisticated equipment for making goniometric measurements, the most commonly used clinical tools are still the universal goniometer and, to a lesser extent, the inclinometer. There is, however, no published study so far that uses an inclinometer for measurements in children with cerebral palsy (CP). The objective of this study was two-fold: to independently assess the intra and inter-examiner reliability for measuring the hip abduction range of motion in children with CP using two different instruments, the universal two-axis goniometer and electronic inclinometer. A pool of 5 examiners with different levels of experience as paediatric physiotherapists participated. The study did not compare both instruments because the measurement procedure and the hip position were different for each.</p> <p>Methods</p> <p>A prospective, observational study of goniometery was carried out with 14 lower extremities of 7 children with spastic CP. The inclinometer study was carried out with 8 lower extremities of 4 children with spastic CP. This study was divided into two independent parts: a study of the reliability of the hip abduction range of motion measured with a universal goniometer (hip at 0° flexion) and with an electronic inclinometer (hip at 90° flexion). The Intraclass Correlation Coefficient (ICC) was calculated to analyse intra and inter-examiner agreement for each instrument.</p> <p>Results</p> <p>For the goniometer, the intra-examiner reliability was excellent (>0.80), while the inter-examiner reliability was low (0.375 and 0.475). For the inclinometer, both the intra-examiner (0.850-0.975) and inter-examiner reliability were excellent (0.965 and 0.979).</p> <p>Conclusions</p> <p>The inter-examiner reliability for goniometric measurement of hip abduction in children with CP was low, in keeping with other results found in previous publications. The inclinometer has proved to be a highly reliable tool for measuring the hip abduction range of motion in children with CP, which opens up new possibilities in this field, despite having some measurement limitations.</p

    Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease

    Get PDF
    Background: Experimental and clinical data suggest that reducing inflammation without affecting lipid levels may reduce the risk of cardiovascular disease. Yet, the inflammatory hypothesis of atherothrombosis has remained unproved. Methods: We conducted a randomized, double-blind trial of canakinumab, a therapeutic monoclonal antibody targeting interleukin-1β, involving 10,061 patients with previous myocardial infarction and a high-sensitivity C-reactive protein level of 2 mg or more per liter. The trial compared three doses of canakinumab (50 mg, 150 mg, and 300 mg, administered subcutaneously every 3 months) with placebo. The primary efficacy end point was nonfatal myocardial infarction, nonfatal stroke, or cardiovascular death. RESULTS: At 48 months, the median reduction from baseline in the high-sensitivity C-reactive protein level was 26 percentage points greater in the group that received the 50-mg dose of canakinumab, 37 percentage points greater in the 150-mg group, and 41 percentage points greater in the 300-mg group than in the placebo group. Canakinumab did not reduce lipid levels from baseline. At a median follow-up of 3.7 years, the incidence rate for the primary end point was 4.50 events per 100 person-years in the placebo group, 4.11 events per 100 person-years in the 50-mg group, 3.86 events per 100 person-years in the 150-mg group, and 3.90 events per 100 person-years in the 300-mg group. The hazard ratios as compared with placebo were as follows: in the 50-mg group, 0.93 (95% confidence interval [CI], 0.80 to 1.07; P = 0.30); in the 150-mg group, 0.85 (95% CI, 0.74 to 0.98; P = 0.021); and in the 300-mg group, 0.86 (95% CI, 0.75 to 0.99; P = 0.031). The 150-mg dose, but not the other doses, met the prespecified multiplicity-adjusted threshold for statistical significance for the primary end point and the secondary end point that additionally included hospitalization for unstable angina that led to urgent revascularization (hazard ratio vs. placebo, 0.83; 95% CI, 0.73 to 0.95; P = 0.005). Canakinumab was associated with a higher incidence of fatal infection than was placebo. There was no significant difference in all-cause mortality (hazard ratio for all canakinumab doses vs. placebo, 0.94; 95% CI, 0.83 to 1.06; P = 0.31). Conclusions: Antiinflammatory therapy targeting the interleukin-1β innate immunity pathway with canakinumab at a dose of 150 mg every 3 months led to a significantly lower rate of recurrent cardiovascular events than placebo, independent of lipid-level lowering. (Funded by Novartis; CANTOS ClinicalTrials.gov number, NCT01327846.

    Probability Theory in Statistical Physics, Percolation, and Other Random Topics: The Work of C. Newman

    Full text link
    In the introduction to this volume, we discuss some of the highlights of the research career of Chuck Newman. This introduction is divided into two main sections, the first covering Chuck's work in statistical mechanics and the second his work in percolation theory, continuum scaling limits, and related topics.Comment: 38 pages (including many references), introduction to Festschrift in honor of C.M. Newma

    Morphing in nature and beyond: a review of natural and synthetic shape-changing materials and mechanisms

    Get PDF
    Shape-changing materials open an entirely new solution space for a wide range of disciplines: from architecture that responds to the environment and medical devices that unpack inside the body, to passive sensors and novel robotic actuators. While synthetic shape-changing materials are still in their infancy, studies of biological morphing materials have revealed key paradigms and features which underlie efficient natural shape-change. Here, we review some of these insights and how they have been, or may be, translated to artificial solutions. We focus on soft matter due to its prevalence in nature, compatibility with users and potential for novel design. Initially, we review examples of natural shape-changing materials—skeletal muscle, tendons and plant tissues—and compare with synthetic examples with similar methods of operation. Stimuli to motion are outlined in general principle, with examples of their use and potential in manufactured systems. Anisotropy is identified as a crucial element in directing shape-change to fulfil designed tasks, and some manufacturing routes to its achievement are highlighted. We conclude with potential directions for future work, including the simultaneous development of materials and manufacturing techniques and the hierarchical combination of effects at multiple length scales.</p

    Genotypic and phenotypic analyses of a Pseudomonas aeruginosa chronic bronchiectasis isolate reveal differences from cystic fibrosis and laboratory strains

    Get PDF
    • …
    corecore