511 research outputs found

    A Facile Fabrication and Transfer Method of Vertically Aligned Carbon Nanotubes on a Mo/Ni Bilayer for Wearable Energy Devices

    Get PDF
    Carbon nanotubes are a promising material for flexible/wearable electrochemical device due to their mechanical softness, chemical stability, and high conductivity. Furthermore, the vertically aligned form of carbon nanotubes (VACNTs) have a large surface area due to their unique three-dimensional (3D) nanostructure. Thus, VACNTs are particularly useful for wearable electrochemical sensors and/or energy devices. However, VACNTs are generally grown via a high-temperature chemical vapor deposition process, which requires a rigid substrate. As a flexible/wearable device platform, therefore, VACNTs should be transferred from rigid substrates to soft substrates. Here, a facile fabrication and transfer method of a unique 3D nanostructure, that is, VACNTs on the Mo/Ni bilayer, for high performance flexible/wearable devices is reported. After growth of VACNTs on a Mo/Ni bilayer, VACNTs with the Mo/Ni bilayer can be easily peeled-off from the SiO2 wafer by using weak adhesion of Ni to SiO2 for transfer printing onto polymeric/elastomeric substrates. Moreover, the Mo layer helps facile growth of VACNTs, and the Mo/Ni bilayer underneath VACNTs maximizes the lateral current flow. The proposed 3D nanostructure (VACNTs on the Mo/Ni bilayer) is successfully applied as flexible electrodes for high-performance wearable asymmetric supercapacitors.

    Wearable Fall Detector using Integrated Sensors and Energy Devices

    Get PDF
    Wearable devices have attracted great attentions as next-generation electronic devices. For the comfortable, portable, and easy-to-use system platform in wearable electronics, a key requirement is to replace conventional bulky and rigid energy devices into thin and deformable ones accompanying the capability of long-term energy supply. Here, we demonstrate a wearable fall detection system composed of a wristband-type deformable triboelectric generator and lithium ion battery in conjunction with integrated sensors, controllers, and wireless units. A stretchable conductive nylon is used as electrodes of the triboelectric generator and the interconnection between battery cells. Ethoxylated polyethylenimine, coated on the surface of the conductive nylon electrode, tunes the work function of a triboelectric generator and maximizes its performance. The electrical energy harvested from the triboelectric generator through human body motions continuously recharges the stretchable battery and prolongs hours of its use. The integrated energy supply system runs the 3-axis accelerometer and related electronics that record human body motions and send the data wirelessly. Upon the unexpected fall occurring, a custom-made software discriminates the fall signal and an emergency alert is immediately sent to an external mobile device. This wearable fall detection system would provide new opportunities in the mobile electronics and wearable healthcare.

    increased Igfbp2 Levels By Placenta-Derived Mesenchymal Stem Cells Enhance Glucose Metabolism in a Taa-injured Rat Model Via ampk Signaling Pathway

    Get PDF
    The insulin resistance caused by impaired glucose metabolism induces ovarian dysfunction due to the central importance of glucose as a source of energy. However, the research on glucose metabolism in the ovaries is still lacking. The objectives of this study were to analyze the effect of PD-MSCs on glucose metabolism through IGFBP2-AMPK signaling and to investigate the correlation between glucose metabolism and ovarian function. Thioacetamide (TAA) was used to construct a rat injury model. PD-MSCs were transplanted into the tail vein (2 × 1

    Large scale and integrated platform for digital mass culture of anchorage dependent cells

    Get PDF
    Industrial applications of anchorage-dependent cells require large-scale cell culture with multifunctional monitoring of culture conditions and control of cell behaviour. Here, we introduce a large-scale, integrated, and smart cell-culture platform (LISCCP) that facilitates digital mass culture of anchorage-dependent cells. LISCCP is devised through large-scale integration of ultrathin sensors and stimulator arrays in multiple layers. LISCCP provides real-time, 3D, and multimodal monitoring and localized control of the cultured cells, which thereby allows minimizing operation labour and maximizing cell culture performance. Wireless integration of multiple LISCCPs across multiple incubators further amplifies the culture scale and enables digital monitoring and local control of numerous culture layers, making the large-scale culture more efficient. Thus, LISCCP can transform conventional labour-intensive and high-cost cell cultures into efficient digital mass cell cultures. This platform could be useful for industrial applications of cell cultures such as in vitro toxicity testing of drugs and cosmetics and clinical scale production of cells for cell therapy.

    Endoscopic Ultrasound-Guided Drainage without Fluoroscopic Guidance for Extraluminal Complicated Cysts

    Get PDF
    Background. Endoscopic ultrasound- (EUS-) guided drainage is generally performed under fluoroscopic guidance. However, improvements in endoscopic and EUS techniques and experience have led to questions regarding the usefulness of fluoroscopy. This study aimed to retrospectively evaluate the safety and efficacy of EUS-guided drainage of extraluminal complicated cysts without fluoroscopic guidance. Methods. Patients who had undergone nonfluoroscopic EUS-guided drainage of extraluminal complicated cysts were enrolled. Drainage was performed via a transgastric, transduodenal, or transrectal approach. Single or double 7 Fr double pigtail stents were inserted. Results. Seventeen procedures were performed in 15 patients in peripancreatic fluid collections (n=13) and pelvic abscesses (n=4). The median lesion size was 7.1 cm (range: 2.8–13.0 cm), and the mean time spent per procedure was 26.2±9.8 minutes (range: 16–50 minutes). Endoscopic drainage was successful in 16 of 17 (94.1%) procedures. There were no complications. All patients experienced symptomatic improvement and revealed partial to complete resolution according to follow-up computed tomography findings. Two patients developed recurrent cysts that were drained during repeat procedures, with eventual complete resolution. Conclusion. EUS-guided drainage without fluoroscopic guidance is a technically feasible, safe, and effective procedure for the treatment of extraluminal complicated cysts

    Heterogeneous stacking of nanodot monolayers by dry pick-and-place transfer and its applications in quantum dot light-emitting diodes

    Get PDF
    Layered assembly structures composed of nanomaterials, such as nanocrystals, have attracted considerable attention as promising candidates for new functional devices whose optical, electromagnetic and electronic behaviours are determined by the spatial arrangement of component elements. However, difficulties in handling each constituent layer in a materialspecific manner limit the 3D integration of disparate nanomaterials into the appropriate heterogeneous electronics. Here we report a pick-and-place transfer method that enables the transfer of large-area nanodot assemblies. This solvent-free transfer utilizes a lifting layer and allows for the reliable transfer of a quantum dot (QD) monolayer, enabling layer-by-layer design. With the controlled multistacking of different bandgap QD layers, we are able to probe the interlayer energy transfer among different QD monolayers. By controlling the emission spectrum through such designed monolayer stacking, we have achieved white emission with stable optoelectronic properties, the closest to pure white among the QD lightemitting diodes reported so far. (c) 2013 Macmillan Publishers Limited. All rights reserved.402
    corecore