643 research outputs found
Energy flux and dissipation of inhomogeneous plane waves in hereditary viscoelasticity
Inhomogeneous small-amplitude plane waves of (complex) frequency ω are propagated through a linear dissipative material which displays hereditary viscoelasticity. The energy density, energy flux and dissipation are quadratic in the small quantities, namely, the displacement gradient, velocity and velocity gradient, each harmonic with frequency ω, and so give rise to attenuated constant terms as well as to inhomogeneous plane waves of frequency 2ω. The quadratic terms are usually removed by time averaging but we retain them here as they are of comparable magnitude with the time-averaged quantities of frequency ω. A new relationship is derived in hereditary viscoelasticity that connects the amplitudes of the terms of the energy density, energy flux and dissipation that have frequency 2ω. It is shown that the complex group velocity is related to the amplitudes of the terms with frequency 2ω rather than to the attenuated constant terms as it is for homogeneous waves in conservative materials
An investigation of minimisation criteria
Minimisation can be used within treatment trials to ensure that prognostic factors are evenly distributed between treatment groups. The technique is relatively straightforward to apply but does require running tallies of patient recruitments to be made and some simple calculations to be performed prior to each allocation. As computing facilities have become more widely available, minimisation has become a more feasible option for many. Although the technique has increased in popularity, the mode of application is often poorly reported and the choice of input parameters not justified in any logical way
Investigating radiatively driven, magnetized plasmas with a university scale pulsed-power generator
We present first results from a novel experimental platform which is able to access physics relevant to topics including indirect-drive magnetised ICF; laser energy deposition; various topics in atomic physics; and laboratory astrophysics (for example the penetration of B-fields into HED plasmas). This platform uses the X-Rays from a wire array Z-Pinch to irradiate a silicon target, producing an outflow of ablated plasma. The ablated plasma expands into ambient, dynamically significant B-fields (~5 T) which are supported by the current flowing through the Z-Pinch. The outflows have a well-defined (quasi-1D) morphology, enabling the study of fundamental processes typically only available in more complex, integrated schemes. Experiments were fielded on the MAGPIE pulsed-power generator (1.4 MA, 240 ns rise time). On this machine a wire array Z-Pinch produces an X-Ray pulse carrying a total energy of ~15 kJ over ~30 ns. This equates to an average brightness temperature of around 10 eV on-target
A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments
A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments
Validity of the Polar V800 heart rate monitor to measure RR intervals at rest
Purpose To assess the validity of RR intervals and short-term heart rate variability (HRV) data obtained from the Polar V800 heart rate monitor, in comparison to an electrocardiograph (ECG). Method Twenty participants completed an active orthostatic test using the V800 and ECG. An improved method for the identification and correction of RR intervals was employed prior to HRV analysis. Agreement of the data was assessed using intra-class correlation coefficients (ICC), Bland–Altman limits of agreement (LoA), and effect size (ES). Results A small number of errors were detected between ECG and Polar RR signal, with a combined error rate of 0.086 %. The RR intervals from ECG to V800 were significantly different, but with small ES for both supine corrected and standing corrected data (ES 0.999 for both supine and standing corrected intervals. When analysed with the same HRV software no significant differences were observed in any HRV parameters, for either supine or standing; the data displayed small bias and tight LoA, strong ICC (>0.99) and small ES (≤0.029). Conclusions The V800 improves over previous Polar models, with narrower LoA, stronger ICC and smaller ES for both the RR intervals and HRV parameters. The findings support the validity of the Polar V800 and its ability to produce RR interval recordings consistent with an ECG. In addition, HRV parameters derived from these recordings are also highly comparable
Assessment of a self-reported Drinks Diary for the estimation of drinks intake by care home residents: Fluid Intake Study in the Elderly (FISE)
Objectives: We evaluated the accuracy of a newly developed self-completed Drinks Diary in care home residents and compared it with direct observation and fluid intake charts. Design: Observational study. Setting: Residential care homes in Norfolk, UK. Participants: 22 elderly people (18 women, mean age 86.6 years SD 8.6, 12 with MMSE scores <27). Measurements: Participants recorded their own drinks intake over 24 hours using the Drinks Diary while care staff used the homes’ usual fluid intake chart to record drinks intake. These records were compared with drinks intake assessed by researcher direct observation (reference method), during waking hours (6am to 10pm), while drinks taken from 10pm to 6am were self-reported and checked with staff. Results: Drinks intake assessed by the Drinks Diary was highly correlated with researcher direct observation (Pearson correlation coefficient r=0.93, p<0.001, mean difference -163ml/day) while few staff-completed fluid charts were returned and correlation was low (r=0.122, p=0.818, mean difference 702ml/day). The Drinks Diary classified 19 of 22 participants correctly as drinking enough or not using both the European Food Safety Authority and US recommendations. Conclusion: The Drinks Diary estimate of drinks intake was comparable with direct observation and more accurate (and reliably completed) than staff records. The Drinks Diary can provide a reliable estimate of drinks intake in elderly care home residents physically and cognitively able to complete it. It may be useful for researchers, care staff and practitioners needing to monitor drinks intake of elderly people, to help them avoid dehydration
Recommended from our members
Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor
Objective
A reliable, continuous method of monitoring splanchnic organ oxygen saturation could allow for the early detection of malperfusion, and may prevent the onset of multiple organ failure. Current monitoring techniques have not been widely accepted in critical care monitoring. As a preliminary to developing a continuous indwelling device, this study evaluates a new handheld fiber optic photoplethysmographic (PPG) sensor for estimating the blood oxygen saturation (SpO2) of splanchnic organs during surgery.
Methods
A fiber optic splanchnic PPG sensor, instrumentation system and virtual instrument were developed to facilitate PPG and SpO2 measurement from splanchnic organs. Following Local Research Ethics Committee approval, the sensor was evaluated on seventeen ASA 1 and 2 patients undergoing open laparotomy. PPG signals were obtained from the large bowel, small bowel, liver and stomach. Simultaneous PPG signals from the finger were also obtained using an identical fiber optic sensor.
Results
Good quality PPG signals with high signal-to-noise (SNR) ratios were obtained from all splanchnic sites under investigation. Analysis of the ac and dc amplitudes of the red and infrared PPG signals showed there to be a statistically significant difference between PPG signals obtained from splanchnic organs with those obtained from the finger (using fiber optic sensors). Estimated SpO2 values from the splanchnic organs show good agreement with those obtained from the finger using both a fiber optic sensor and a commercial device. Furthermore, the results of a Bland and Altman analysis indicate that fiber optic splanchnic pulse oximetry, particularly of the bowel, may provide a suitable method for monitoring splanchnic organ perfusion.
Conclusion
The evaluation of a new fiber optic sensor on anaesthetized patients undergoing laparotomy demonstrated that good quality PPG signals and SpO2 estimates can be obtained from splanchnic organs. Such a sensor may provide a useful tool for the intraoperative assessment of splanchnic perfusion
Lactate Regulates Metabolic and Proinflammatory Circuits in Control of T Cell Migration and Effector Functions
Licensed by the Creative Commons Attribution Licens
- …