403 research outputs found

    Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results.</p> <p>Methods</p> <p>Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and <it>Plasmodium </it>positive samples.</p> <p>Results</p> <p>Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all <it>Plasmodium </it>antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and <it>Plasmodium </it>positive samples.</p> <p>Conclusion</p> <p>Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.</p

    Evaluation of the rapid diagnostic test SDFK40 (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a non-endemic setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting <it>Plasmodium falciparum</it>-specific parasite lactate dehydrogenase (Pf-pLDH) and pan <it>Plasmodium</it>-specific pLDH (pan-pLDH), in a reference setting.</p> <p>Methods</p> <p>The SDFK40 was retrospectively and prospectively tested against a panel of stored (n = 341) and fresh (n = 181) whole blood samples obtained in international travelers suspected of malaria, representing the four <it>Plasmodium </it>species as well as <it>Plasmodium </it>negative samples, and compared to microscopy and PCR results. The prospective panel was run together with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH).</p> <p>Results</p> <p>Overall sensitivities for <it>P. falciparum </it>tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities >1,000/μl. Sensitivity at parasite densities ≤ 100/μl was 9.1%. Overall sensitivities for <it>Plasmodium vivax </it>and <it>Plasmodium ovale </it>were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities >500/μl. Sensitivity for <it>Plasmodium malariae </it>was 21.4%. Species mismatch occurred in 0.7% of samples (3/411) and was limited to non-<it>falciparum </it>species erroneously identified as <it>P. falciparum</it>. None of the <it>Plasmodium </it>negative samples in the retrospective panel reacted positive. Compared to OptiMAL and SDFK60, SDFK40 showed lower sensitivities for <it>P. falciparum</it>, but better detection of <it>P. ovale</it>. Inter-observer agreement and test reproducibility were excellent, but lot-to-lot variability was observed for pan-pLDH results in case of <it>P. falciparum</it>.</p> <p>Conclusion</p> <p>SDFK40 performance was poor at low (≤ 100/μl) parasite densities, precluding its use as the only diagnostic tool for malaria diagnosis. SDFK40 performed excellent for <it>P. falciparum </it>samples at high (>1,000/μl) parasite densities as well as for detection of <it>P. vivax </it>and <it>P. ovale </it>at parasite densities >500/μl.</p

    The course of the superficial peroneal nerve in relation to the ankle position: anatomical study with ankle arthroscopic implications

    Get PDF
    Despite the fact that the superficial peroneal nerve is the only nerve in the human body that can be made visible; iatrogenic damage to this nerve is the most frequently reported complication in anterior ankle arthroscopy. One of the methods to visualize the nerve is combined ankle plantar flexion and inversion. In the majority of cases, the superficial peroneal nerve can be made visible. The portals for anterior ankle arthroscopy are however created with the ankle in the neutral or slightly dorsiflexed position and not in combined plantar flexion and inversion. The purpose of this study was to undertake an anatomical study to the course of the superficial peroneal nerve in different positions of the foot and ankle. We hypothesize that the anatomical localization of the superficial peroneal nerve changes with different foot and ankle positions. In ten fresh frozen ankle specimens, a window, only affecting the skin, was made at the level of the anterolateral portal for anterior ankle arthroscopy in order to directly visualize the superficial peroneal nerve, or if divided, its terminal branches. Nerve movement was assessed from combined 10° plantar flexion and inversion to 5° dorsiflexion, standardized by the Telos stress device. Also for the 4th toe flexion, flexion of all the toes and for skin tensioning possible nerve movement was determined. The mean superficial peroneal nerve movement was 2.4 mm to the lateral side when the ankle was moved from 10° plantar flexion and inversion to the neutral ankle position and 3.6 mm to the lateral side from 10° plantar flexion and inversion to 5° dorsiflexion. Both displacements were significant (P < 0.01). The nerve consistently moves lateral when the ankle is manoeuvred from combined plantar flexion and inversion to the neutral or dorsiflexed position. If visible, it is therefore advised to create the anterolateral portal medial from the preoperative marking, in order to prevent iatrogenic damage to the superficial peroneal nerve

    What lies beneath: exploring links between asylum policy and hate crime in the UK

    Get PDF
    This paper explores the link between increasing incidents of hate crime and the asylum policy of successive British governments with its central emphasis on deterrence. The constant problematisation of asylum seekers in the media and political discourse ensures that 'anti-immigrant' prejudice becomes mainstr earned as a common-sense response. The victims are not only the asylum seekers hoping for a better life but democratic society itself with its inherent values of pluralism and tolerance debased and destabilised

    External quality assessment on the use of malaria rapid diagnostic tests in a non-endemic setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are increasingly used as a tool for the diagnosis of malaria, both in endemic and in non-endemic settings. The present study reports the results of an external quality assessment (EQA) session on RDTs in a non-endemic setting.</p> <p>Methods</p> <p>After validation of antigen stability during shipment at room temperature, three clinical samples and a questionnaire were sent to clinical laboratories in Belgium and the Grand Duchy of Luxembourg using malaria RDTs. Participants were asked to report the results of the RDTs as observations (visibility of the RDT control and test lines) and interpretations (report as formulated to the clinician). In addition, participants were invited to fill in a questionnaire on the place of RDTs in the diagnostic strategy of malaria.</p> <p>Results</p> <p>A total of 128/133 (96.2%) of clinical laboratories using RDTs participated. Six three-band and one four-band RDT brands were used. Analytical errors were rare and included (i) not recognizing invalid RDT results (1.6%) and (ii) missing the diagnosis of <it>Plasmodium falciparum </it>(0.8%). Minor errors were related to RDT test result interpretation and included (i) reporting "RDT positive" without species identification in the case of <it>P. falciparum </it>and non-<it>falciparum </it>species (16.9% and 6.5% respectively) and (ii) adding incorrect comments to the report (3.2%). Some of these errors were related to incorrect RDT package insert instructions such as (i) not reporting the possibility of mixed species infection in the case of <it>P. falciparum </it>and <it>Plasmodium vivax </it>(35.5% and 18.5% respectively) and (ii) the interpretation of <it>P. vivax </it>instead of non-falciparum species at the presence of a pan-species antigen line (4.0%). According to the questionnaire, 48.8% of participants processed ≤20 requests for malaria diagnosis in 2009. During opening hours, 93.6% of 125 participants used RDTs as an adjunct to microscopy but outside opening hours, nearly one third of 113 participants relied on RDTs as the primary (4.4%) or the single tool (25.7%) for malaria diagnosis.</p> <p>Conclusion</p> <p>In this non-endemic setting, errors in RDT performance were mainly related to RDT test line interpretations, partly due to incorrect package insert instructions. The reliance on RDTs as the primary or the single tool for the diagnosis of malaria outside opening hours is of concern and should be avoided.</p

    How to juggle priorities? An interactive tool to provide quantitative support for strategic patient-mix decisions: an ophthalmology case

    Get PDF
    An interactive tool was developed for the ophthalmology department of the Academic Medical Center to quantitatively support management with strategic patient-mix decisions. The tool enables management to alter the number of patients in various patient groups and to see the consequences in terms of key performance indicators. In our case study, we focused on the bottleneck: the operating room. First, we performed a literature review to identify all factors that influence an operating room's utilization rate. Next, we decided which factors were relevant to our study. For these relevant factors, two quantitative methods were applied to quantify the impact of an individual factor: regression analysis and computer simulation. Finally, the average duration of an operation, the number of cancellations due to overrun of previous surgeries, and the waiting time target for elective patients all turned out to have significant impact. Accordingly, for the case study, the interactive tool was shown to offer management quantitative decision support to act proactively to expected alterations in patient-mix. Hence, management can anticipate the future situation, and either alter the expected patient-mix or expand capacity to ensure that the key performance indicators will be met in the future

    Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information.</p> <p>Methods</p> <p>Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed.</p> <p>Results</p> <p>Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (<it>i.e</it>. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to <it>Plasmodium vivax </it>although targeting a pan-species <it>Plasmodium </it>antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups.</p> <p>Conclusion</p> <p>Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.</p

    Giemsa-stained thick blood films as a source of DNA for Plasmodium species-specific real-time PCR

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study describes the use of thick blood films (TBF) as specimens for DNA amplification with the <it>Plasmodium </it>species-specific real-time PCR that was recently validated on whole blood samples.</p> <p>Methods</p> <p>The panel of 135 Giemsa-stained clinical TBFs represented single infections of the four <it>Plasmodium </it>species with varying parasite densities or only gametocytes, mixed infections, and negative samples and was stored for up to 12 years. Half of the Giemsa-stained TBF was scraped off by a sterile scalpel and collected into phosphate buffered saline. DNA was extracted with the Qiagen DNA mini kit with minor modifications. DNA was amplified with the 18S rRNA real-time PCR targeting the four <it>Plasmodium </it>species with four species-specific primers and probes in combination with one genus-specific reverse primer. Results of the PCR on TBF were compared to those of the PCR on whole blood and to microscopy.</p> <p>Results</p> <p>Correct identification for single species infections was obtained for all TBF samples with <it>Plasmodium falciparum </it>(n = 50), <it>Plasmodium vivax </it>(n = 25), <it>Plasmodium ovale </it>(n = 25) and in all but one samples with <it>Plasmodium malariae </it>(n = 10). Compared to whole blood samples, higher Ct-values were observed by PCR on TBF with a mean difference of 5.93. Four out of five mixed infections were correctly identified with PCR on TBF. None of the negative samples (n = 20) gave a PCR signal. PCR on TBF showed a detection limit of 0.2 asexual parasites/μl compared to 0.02/μl for whole blood. Intra-run variation was higher for PCR on TBF (%CV 1.90) compared to PCR on whole blood (%CV 0.54). Compared to microscopy, PCR on TBF generated three more species identifications in samples containing a single species and detected the same four mixed-infections.</p> <p>Conclusions</p> <p>Giemsa-stained TBFs are a reliable source of DNA for <it>Plasmodium </it>real-time PCR analysis, allowing applications in reference and research settings in case whole blood samples are not available.</p
    corecore