137 research outputs found

    Three-year findings of the HORIZON trial: a Schlemm canal microstent for pressure reduction in primary open angle glaucoma and cataract

    Get PDF
    OBJECTIVE: To report 3-year outcomes of the HORIZON study comparing cataract surgery with Hydrus Microstent versus cataract surgery alone. DESIGN: Multicenter randomized clinical trial. PARTICIPANTS: Five hundred fifty-six eyes from 556 patients with cataract and POAG treated with ≥ 1 glaucoma medication, washed out diurnal intraocular pressure (DIOP) 22-34 mmHg and no prior incisional glaucoma surgery. METHODS: Following phacoemulsification, eyes were randomized 2:1 to receive a Hydrus® Microstent (Ivantis, Inc.) or no stent. Follow-up included comprehensive eye examinations through 3 years postoperatively. MAIN OUTCOME MEASURES: Outcome measures included IOP, medical therapy, reoperation rates, visual acuity, adverse events, and changes in corneal endothelial cell counts. RESULTS: 369 eyes were randomized to microstent treatment (HMS) and 187 to cataract surgery only (CS). Preoperative IOP, medication usage, washed out DIOP, and glaucoma severity did not differ between the two treatment groups. At 3 years, IOP was 16.7 ± 3.1 in the HMS group and 17.0 ± 3.4 in the CS group (p=0.85). The number of glaucoma medications was 0.4 ± 0.8 in the HMS group and 0.8 ± 1.0 in the CS group (p<0.001), and 73% of eyes in the HMS group were medication free compared to 48% in the CS group (p<0.001). The HMS group had a higher proportion of eyes with IOP ≤18 mmHg without medications compared to CS (56.2% vs. 34.6%, p<0.001) as well as IOP reduction of at least 20, 30 or 40 percent compared to CS alone. The cumulative probability of incisional glaucoma surgery was lower in the HMS group (0.6% vs. 3.9%, hazard ratio = 0.156, 95% CI 0.031 to 0.773, p=0.020). There was no difference in postoperative corneal endothelial cell loss between groups. There were no procedure or device related serious adverse events resulting in vision loss in either group. CONCLUSIONS: Combined cataract surgery and microstent placement for mild to moderate POAG is safe, more effective in lowering IOP with fewer medications, and less likely to result in further incisional glaucoma filtrations surgery than cataract surgery alone at 3 years

    Human rights, non-refoulement and the protection of refugees in Hong Kong

    Get PDF
    Although the 1951 Convention relating to the Status of Refugees and its 1967 Protocol do not apply to Hong Kong, asylum seekers have challenged Hong Kong's lack of an adequate refugee policy in a series of judicial review actions grounded in human rights and common law principles. This article focuses on two cases in particular in which the applicants have attempted to rely, in part, on a right to non-refoulement, derived from international and domestic law, to compel the Government to establish procedures to determine the status of refugees and other similar categories of claimants. The first, Secretary for Security v. Sakthevel Prabakar, led to the creation of a 'torture screening' mechanism based on article 3 of the Convention against Torture and other Cruel, Inhuman, or Degrading Treatment or Punishment. In the second, C v. Director of Immigration, the court considered whether a rule of non-refoulement has emerged in customary international law and, if so, whether it applies to Hong Kong and requires government-administered refugee status determination. Although the applicants failed at first instance,1 an analysis of the judgment with reference to Hong Kong's human rights obligations reveals gaps in the court's reasoning and demonstrates the potential for greater reliance on these standards as the basis for developing a more comprehensive protection framework. This examination of the Hong Kong experience may have broader comparative value, especially in the Asian region and in jurisdictions not bound by the Refugee Convention or its Protocol. © The Author (2010). Published by Oxford University Press. All rights reserved.postprin

    Are component positioning and prosthesis size associated with hip resurfacing failure?

    Get PDF
    BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve

    Quality of life: international and domestic students studying medicine in New Zealand

    Get PDF
    International students form a significant proportion of students studying within universities in Western countries. The quality of life perceptions of international medical students in comparison with domestic medical students has not been well documented. There is some evidence to suggest that international medical students may have different educational and social experiences in relation to their domestic peers. This study investigates the levels of quality of life experienced by international and domestic students studying medicine. A total of 548 medical students completed the abbreviated version of the World Health Organization Quality of Life questionnaire. The focus of the analysis was to evaluate differences between international and domestic students in their early clinical years. The responses were analysed using multivariate analysis of variance methods. International medical students are experiencing lower social and environmental quality of life compared with domestic peers. International medical students in New Zealand have expressed quality of life concerns, which likely have an impact on their academic achievement, feelings of wellness, acculturation, and social adaptation. The findings reinforce the need for creating stronger social networks and accessible accommodation, as well as developing systems to ensure safety, peer mentorship and student support.published_or_final_versio

    Small and medium-sized enterprise policy: Designed to fail?

    Get PDF
    Significant doubts persist over the effectiveness of government policy to increase the numbers or performance of small and medium-sized enterprises in the UK economy. We analyse UK political manifestoes from 1964-2015 to examine the development of SME policy in political discourse. We do this by analysing how the broadly-defined category of ‘SME’ has been characterised in the manifestoes and assess these characterisations in relation to the empirical evidence base. We highlight three consistent themes in UK political manifestoes during 1964-2015 where SMEs have been characterised as having the potential for growth, struggling to access finance and being over-burdened by regulation. We argue that homogenising the broad range of businesses represented by the SME category and characterising them in these terms misrepresents them, undermining policies developed in relation to this mischaracterisation

    ADP Ribosylation Factor Like 2 (Arl2) Regulates Breast Tumor Aggressivity in Immunodeficient Mice

    Get PDF
    We have previously reported that ADP ribosylation factor like 2 (Arl2), a small GTPase, content influences microtubule dynamics and cell cycle distribution in breast tumor cells, as well as the degree and distribution of phosphorylated P53. Here we show, in two different human breast adenocarcinoma models, that Arl2 content has a major impact on breast tumor cell aggressivity both in vitro and in vivo. Cells with reduced content of Arl2 displayed reduced contact inhibition, increased clonogenic or cluster formation as well as a proliferative advantage over control cells in an in vitro competition assay. These cells also caused larger tumors in SCID mice, a phenotype which was mimicked by the in vivo administration of siRNA directed against Arl2. Cells with increased Arl2 content displayed reduced aggressivity, both in vitro and in vivo, with enhanced necrosis and were also found to contain increased PP2A phosphatase activity. A rt-PCR analysis of fresh human tumor breast samples suggested that low Arl2 expression was associated with larger tumor size and greater risk of lymph node involvement at diagnosis. These data underline the role of Arl2, a small GTPase, as an important regulator of breast tumor cell aggressivity, both in vitro and in vivo

    Systematic review of studies examining transtibial prosthetic socket pressures with changes in device alignment

    Get PDF
    Suitable lower-limb prosthetic sockets must provide an adequate distribution of the pressures created from standing and ambulation. A systematic search for articles reporting socket pressure changes in response to device alignment perturbation was carried out, identifying 11 studies. These were then evaluated using the American Academy of Orthotists and Prosthetists guidelines for a state-of-the-science review. Each study used a design where participants acted as their own controls. Results were available for 52 individuals and 5 forms of alignment perturbation. Four studies were rated as having moderate internal and external validity, the remainder were considered to have low validity. Significant limitations in study design, reporting quality and in representation of results and the suitability of calculations of statistical significance were evident across articles. Despite the high inhomogeneity of study designs, moderate evidence supports repeatable changes in pressure distribution for specific induced changes in component alignment. However, there also appears to be a significant individual component to alignment responses. Future studies should aim to include greater detail in the presentation of results to better support later meta-analyses
    corecore