90 research outputs found

    Bioremediation of lead using spore surface displayed proteins

    Get PDF
    Lead is a toxic pollutant very harmful to human health since it accumulates in the body and affects the brain, liver, kidney, and bones. Fetuses can be exposed to lead during pregnancy, which can cause problems with learning later on in the baby’s life. The purpose of this project is to display a lead binding protein on bacterial spore surface for the bioremediation of lead from water. Spores from Bacillus subtilis are very robust and resistant to various harsh environments. Genetically fused to a spore surface protein, the displayed proteins demonstrate enhanced robustness and can be easily produced through sporulation without the need of further purification. PbrR is a regulatory protein that modulates the lead resistance in bacteria. In this project, we fused seven variants of PbrR to the spore surface protein CotC (CotC-PbrRs). The lead binding affinity and specificity of these PbrR variants on the spore surface will be characterized. The robustness of these spores with PbrR will be also evaluated using wastewater samples

    Statistical correlation between enterovirus genome copy numbers and infectious viral particles in wastewater samples

    Get PDF
    Aims: Classic virological tests are time consuming and labour-intensive; realtime RT-PCR has proven to be a fast method to detect and quantify enterovirus genomes in clinical and environmental samples. This method is unable to discriminate between infective and noninfective enterovirus particles; few clinical studies have compared real-time RT-PCR and viral culture. We wondered if the enterovirus genome quantification could be correlated to the infectivity. Methods and Results: We used the statistical approach to verify our hypotheses to correlate data, obtained by the standard method (most probable number of cytopathic units—MPNCU) and molecular test (real-time RT-PCR), on wastewater treatment plant samples. Chi-squared test was used, considering several cut-off values (‘50’-‘100’-‘200’ genome copy numbers), to determine statistical significance in comparison of the two methods. Chi-square value was not significant when cut-off of 50 (P = 0Æ103) and 100 (P = 0Æ178) was assumed but was significant with cut-off of 200 (P = 0Æ044). Conclusion: This limit, 200 genome copy, could be used as cut-off value to indicate enterovirus survival in environmental monitoring. Significant and Impact of the Study: To introduce a fast procedure that is able to compensate for disadvantages of cell culture method for viral environmental analyses

    Electrochemical oxidation of water on synthetic boron-doped diamond thin film anodes

    Get PDF
    Electrolysis in aqueous 1 M HClO4 and 1 M H2SO4 solutions has been carried out under galvanostatic conditions using boron-doped diamond electrodes (BDD). Analyses of the oxidation products have shown that in 1 M HClO4 the main reaction is oxygen evolution, while in H2SO4 the main reaction is the formation of H2S2O8. In both electrolytes small amounts of O3 and H2O2 are formed. Finally, a simplified mechanism involving hydroxyl radicals formed by water discharge has been proposed for water oxidation on boron-doped diamond anode

    A multicentre, open-label, single-arm phase II trial of the efficacy and safety of sclerotherapy using 3% polidocanol foam to treat second-degree haemorrhoids (SCLEROFOAM)

    Get PDF
    Background The aim of the present study was to evaluate the efficacy and safety of 3% polidocanol foam for treating 2nd-degree haemorrhoids. Methods A multicentre, open-label, single-arm, phase 2 trial involving 10 tertiary referral centres for haemorrhodal disease (HD) was performed. Between January and June 2019, patients with 2nd-degree haemorrhoids were prospectively included in this study. The primary outcome was to establish the success rate after one sclerotherapy session in terms of complete resolution of bleeding episodes one week after the injection. The Hemorrhoidal Disease Symptom Score (HDSS), the Short Health Scale for HD (SHS-HD) score and the Vaizey incontinence score were used to assess symptoms and their impact on quality of life and continence. Pain after the procedure, subjective symptoms and the amount and type of painkillers used were recorded. Patients were followed up for 1 year. Results There were 183 patients [111 males; 60.7%, mean age 51.3 +/- 13.5 (18-75) years]. Complete resolution of bleeding was reached in 125/183 patients (68.3%) at 1 week and the recurrence rate was 12% (15/125). Thirteen patients (7.4%) underwent a second sclerotherapy session, while only 1 patient (1.8%) had to undergo a third session. The overall 1-year success rate was 95.6% (175/183). The HDSS and the SHS score significantly improved from a median preoperative value of 11 and 18 to 0 and 0, respectively (p < 0.001). There were 3 episodes of external thrombosis. No serious adverse events occurred. Conclusions Sclerotherapy with 3% polidocanol foam is a safe, effective, painless, repeatable and low-cost procedure in patients with bleeding haemorrhoids. © 2022, The Author(s)

    A multicentre, open-label, single-arm phase II trial of the efficacy and safety of sclerotherapy using 3% polidocanol foam to treat second-degree haemorrhoids (SCLEROFOAM)

    Get PDF
    Background: The aim of the present study was to evaluate the efficacy and safety of 3% polidocanol foam for treating 2nd-degree haemorrhoids. Methods: A multicentre, open-label, single-arm, phase 2 trial involving 10 tertiary referral centres for haemorrhodal disease (HD) was performed. Between January and June 2019, patients with 2nd-degree haemorrhoids were prospectively included in this study. The primary outcome was to establish the success rate after one sclerotherapy session in terms of complete resolution of bleeding episodes one week after the injection. The Hemorrhoidal Disease Symptom Score (HDSS), the Short Health Scale for HD (SHS-HD) score and the Vaizey incontinence score were used to assess symptoms and their impact on quality of life and continence. Pain after the procedure, subjective symptoms and the amount and type of painkillers used were recorded. Patients were followed up for 1 year. Results: There were 183 patients [111 males; 60.7%, mean age 51.3 ± 13.5 (18–75) years]. Complete resolution of bleeding was reached in 125/183 patients (68.3%) at 1 week and the recurrence rate was 12% (15/125). Thirteen patients (7.4%) underwent a second sclerotherapy session, while only 1 patient (1.8%) had to undergo a third session. The overall 1-year success rate was 95.6% (175/183). The HDSS and the SHS score significantly improved from a median preoperative value of 11 and 18 to 0 and 0, respectively (p < 0.001). There were 3 episodes of external thrombosis. No serious adverse events occurred. Conclusions: Sclerotherapy with 3% polidocanol foam is a safe, effective, painless, repeatable and low-cost procedure in patients with bleeding haemorrhoids

    A 12-month follow-up of the immune response to SARS-CoV-2 primary vaccination: evidence from a real-world study

    Get PDF
    A real-world population-based longitudinal study, aimed at determining the magnitude and duration of immunity induced by different types of vaccines against COVID-19, started in 2021 by enrolling a cohort of 2,497 individuals at time of their first vaccination. The study cohort included both healthy adults aged ≤65 years and elderly subjects aged >65 years with two or more co-morbidities. Here, patterns of anti-SARS-CoV-2 humoral and cell-mediated specific immune response, assessed on 1,182 remaining subjects, at 6 (T6) and 12 months (T12) after the first vaccine dose, are described. At T12 median anti-Spike IgG antibody levels were increased compared to T6. The determinants of increased anti-Spike IgG were the receipt of a third vaccine dose between T6 and T12 and being positive for anti-Nucleocapside IgG at T12, a marker of recent infection, while age had no significant effect. The capacity of T12 sera to neutralize in vitro the ancestral B strain and the Omicron BA.5 variant was assessed in a subgroup of vaccinated subjects. A correlation between anti-S IgG levels and sera neutralizing capacity was identified and higher neutralizing capacity was evident in healthy adults compared to frail elderly subjects and in those who were positive for anti-Nucleocapside IgG at T12. Remarkably, one third of T12 sera from anti-Nucleocapside IgG negative older individuals were unable to neutralize the BA.5 variant strain. Finally, the evaluation of T-cell mediated immunity showed that most analysed subjects, independently from age and comorbidity, displayed Spike-specific responses with a high degree of polyfunctionality, especially in the CD8 compartment. In conclusion, vaccinated subjects had high levels of circulating antibodies against SARS-CoV-2 Spike protein 12 months after the primary vaccination, which increased as compared to T6. The enhancing effect could be attributable to the administration of a third vaccine dose but also to the occurrence of breakthrough infection. Older individuals, especially those who were anti-Nucleocapside IgG negative, displayed an impaired capacity to neutralize the BA.5 variant strain. Spike specific T-cell responses, able to sustain immunity and maintain the ability to fight the infection, were present in most of older and younger subjects assayed at T1

    Measurement of Epstein-Barr virus DNA load using a novel quantification standard containing two EBV DNA targets and SYBR Green I dye

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reactivation of Epstein-Barr virus (EBV) infection may cause serious, life-threatening complications in immunocompromised individuals. EBV DNA is often detected in EBV-associated disease states, with viral load believed to be a reflection of virus activity. Two separate real-time quantitative polymerase chain reaction (QPCR) assays using SYBR Green I dye and a single quantification standard containing two EBV genes, Epstein-Barr nuclear antigen-1 (EBNA-1) and BamHI fragment H rightward open reading frame-1 (BHRF-1), were developed to detect and measure absolute EBV DNA load in patients with various EBV-associated diseases. EBV DNA loads and viral capsid antigen (VCA) IgG antibody titres were also quantified on a population sample.</p> <p>Results</p> <p>EBV DNA was measurable in ethylenediaminetetraacetic acid (EDTA) whole blood, peripheral blood mononuclear cells (PBMCs), plasma and cerebrospinal fluid (CSF) samples. EBV DNA loads were detectable from 8.0 × 10<sup>2 </sup>to 1.3 × 10<sup>8 </sup>copies/ml in post-transplant lymphoproliferative disease (n = 5), 1.5 × 10<sup>3 </sup>to 2.0 × 10<sup>5 </sup>copies/ml in infectious mononucleosis (n = 7), 7.5 × 10<sup>4 </sup>to 1.1 × 10<sup>5 </sup>copies/ml in EBV-associated haemophagocytic syndrome (n = 1), 2.0 × 10<sup>2 </sup>to 5.6 × 10<sup>3 </sup>copies/ml in HIV-infected patients (n = 12), and 2.0 × 10<sup>2 </sup>to 9.1 × 10<sup>4 </sup>copies/ml in the population sample (n = 218). EBNA-1 and BHRF-1 DNA were detected in 11.0% and 21.6% of the population sample respectively. There was a modest correlation between VCA IgG antibody titre and BHRF-1 DNA load (rho = 0.13, p = 0.05) but not EBNA-1 DNA load (rho = 0.11, p = 0.11).</p> <p>Conclusion</p> <p>Two sensitive and specific real-time PCR assays using SYBR Green I dye and a single quantification standard containing two EBV DNA targets, were developed for the detection and measurement of EBV DNA load in a variety of clinical samples. These assays have application in the investigation of EBV-related illnesses in immunocompromised individuals.</p
    corecore