303 research outputs found

    Evaluation of the effects of different groove length and thickness of the retainers on the retention of maxillary anterior base metal resin bonded retainers ' an in vitro study

    Get PDF
    Objectives: The resin-bonded fixed partial dentures have gained immense popularity in recent years as they are more conservative, esthetic, economic and easily fabricated. However debonding is considered the most common cause of failure of resin bonded prosthesis. The objective of the study were to compare the effects of different groove lengths and thickness of retainers on retention of maxillary anterior base metal resin bonded retainers. Study Design: Twenty five metal dies of maxillary central incisor duplicated from pure typhodont teeth (maxillary left central incisors) prepared to receive retainer for resin bonded fixed partial denture having different test designs were made. Five test groups were made with each group having five specimens. Two groups were having preparation depth of 0.5mm and retention groove lengths of 3mm and 5mm. Two groups had preparation depths of 0.3 and 0.7mm with no groove preparation with retainer thickness of 0.3 and 0.7mm respectively. Fifth group with no groove preparation and preparation depth of 0.5mm was kept as control for all the groups. All the specimens were cemented using calibra (Dentsply) resin cement. Each specimen was subjected to tensile loading in vertical direction on universal testing machine (Instron 5569) at a crosshead speed of 1mm/min. \ Results: Groups with 5mm and 3mm groove length recorded higher mean vertical forces when compared to the group with no groove preparation. Group with 5mm groove length showed highest mean vertical forces. The group with 0.7mm retainer recorded higher mean vertical force values when compared to groups with 0.5mm and 0.3mm retainer thickness. Group with 0.3mm retainer thickness recorded the least mean vertical force value. Conclusion: Placement of the grooves increased the retention values almost 2 ½ times than the grooveless preparation and as the thickness of the retainers increased retention values also increased. Retention value was directly proportional to the groove length and retainer thickness

    Reconstruction of a midfacial defect using an intraoral-extraoral combination prosthesis employing magnets: a clinical report

    Get PDF
    Radical maxillectomy frequently leads to extended defects in hard and soft tissues that result in a connection between the oral cavities and orbit. If the defect cannot be surgically reconstructed, a combination prosthesis may be necessary to remedy dysfunction in patient function, comfort, esthetics. For minor defects, enlargement of the base of the intra oral prosthesis is generally sufficient. Resections that affect more than one third of the maxilla usually require an intra oral and an extra oral prosthesis that could be assembled and retained in the patient. This clinical report describes a technique of prosthetic rehabilitation of midfacial defect with a silicone orbital prosthesis and intra oral obturator that are retained by magnets

    Multiband tight-binding theory of disordered ABC semiconductor quantum dots: Application to the optical properties of alloyed CdZnSe nanocrystals

    Full text link
    Zero-dimensional nanocrystals, as obtained by chemical synthesis, offer a broad range of applications, as their spectrum and thus their excitation gap can be tailored by variation of their size. Additionally, nanocrystals of the type ABC can be realized by alloying of two pure compound semiconductor materials AC and BC, which allows for a continuous tuning of their absorption and emission spectrum with the concentration x. We use the single-particle energies and wave functions calculated from a multiband sp^3 empirical tight-binding model in combination with the configuration interaction scheme to calculate the optical properties of CdZnSe nanocrystals with a spherical shape. In contrast to common mean-field approaches like the virtual crystal approximation (VCA), we treat the disorder on a microscopic level by taking into account a finite number of realizations for each size and concentration. We then compare the results for the optical properties with recent experimental data and calculate the optical bowing coefficient for further sizes

    Determining the impact of an artificial intelligence tool on the management of pulmonary nodules detected incidentally on CT (DOLCE) study protocol: a prospective, non-interventional multicentre UK study.

    Get PDF
    Introduction In a small percentage of patients, pulmonary nodules found on CT scans are early lung cancers. Lung cancer detected at an early stage has a much better prognosis. The British Thoracic Society guideline on managing pulmonary nodules recommends using multivariable malignancy risk prediction models to assist in management. While these guidelines seem to be effective in clinical practice, recent data suggest that artificial intelligence (AI)-based malignant-nodule prediction solutions might outperform existing models. Methods and analysis This study is a prospective, observational multicentre study to assess the clinical utility of an AI-assisted CT-based lung cancer prediction tool (LCP) for managing incidental solid and part solid pulmonary nodule patients vs standard care. Two thousand patients will be recruited from 12 different UK hospitals. The primary outcome is the difference between standard care and LCP-guided care in terms of the rate of benign nodules and patients with cancer discharged straight after the assessment of the baseline CT scan. Secondary outcomes investigate adherence to clinical guidelines, other measures of changes to clinical management, patient outcomes and cost-effectiveness. Ethics and dissemination This study has been reviewed and given a favourable opinion by the South Central—Oxford C Research Ethics Committee in UK (REC reference number: 22/SC/0142). Study results will be available publicly following peer-reviewed publication in open-access journals. A patient and public involvement group workshop is planned before the study results are available to discuss best methods to disseminate the results. Study results will also be fed back to participating organisations to inform training and procurement activities. Trial registration number NCT05389774

    Measurement of differential cross sections for Z bosons produced in association with charm jets in pp collisions at √s = 13 TeV

    Get PDF

    Search for MSSM Higgs bosons decaying to μ⁺μ⁻ in proton-proton collisions at √s = 13 TeV

    Get PDF

    Pileup mitigation at CMS in 13 TeV data

    Get PDF
    With increasing instantaneous luminosity at the LHC come additional reconstruction challenges. At high luminosity, many collisions occur simultaneously within one proton-proton bunch crossing. The isolation of an interesting collision from the additional "pileup" collisions is needed for effective physics performance. In the CMS Collaboration, several techniques capable of mitigating the impact of these pileup collisions have been developed. Such methods include charged-hadron subtraction, pileup jet identification, isospin-based neutral particle "δβ" correction, and, most recently, pileup per particle identification. This paper surveys the performance of these techniques for jet and missing transverse momentum reconstruction, as well as muon isolation. The analysis makes use of data corresponding to 35.9 fb1^{-1} collected with the CMS experiment in 2016 at a center-of-mass energy of 13 TeV. The performance of each algorithm is discussed for up to 70 simultaneous collisions per bunch crossing. Significant improvements are found in the identification of pileup jets, the jet energy, mass, and angular resolution, missing transverse momentum resolution, and muon isolation when using pileup per particle identification

    Search for Higgs and Z boson decays to J/ψ or Y pairs in the four-muon final state in proton-proton collisions at √s = 13 TeV

    Get PDF
    corecore