784 research outputs found

    3D performance capture for facial animation

    Get PDF
    This work describes how a photogrammetry based 3D capture system can be used as an input device for animation. The 3D Dynamic Capture System is used to capture the motion of a human face, which is extracted from a sequence of 3D models captured at TV frame rate. Initially the positions of a set of landmarks on the face are extracted. These landmarks are then used to provide motion data in two different ways. First, a high level description of the movements is extracted, and these can be used as input to a procedural animation package (i.e. CreaToon). Second the landmarks can be used as registration points for a conformation process where the model to be animated is modified to match the captured model. This approach gives a new sequence of models, which have the structure of the drawn model but the movement of the captured sequence

    Charge Form Factor and Cluster Structure of 6^6Li Nucleus

    Full text link
    The charge form factor of 6{}^6Li nucleus is considered on the basis of its cluster structure. The charge density of 6{}^6Li is presented as a superposition of two terms. One of them is a folded density and the second one is a sum of 4{}^4He and the deuteron densities. Using the available experimental data for 4{}^4He and deuteron charge form factors, a good agreement of the calculations within the suggested scheme is obtained with the experimental data for the charge form factor of 6{}^6Li, including those in the region of large transferred momenta.Comment: 12 pages 5 figure

    Transient Magnetic and Doppler Features Related to the White-light Flares in NOAA 10486

    Full text link
    Rapidly moving transient features have been detected in magnetic and Doppler images of super-active region NOAA 10486 during the X17/4B flare of 28 October 2003 and the X10/2B flare of 29 October 2003. Both these flares were extremely energetic white-light events. The transient features appeared during impulsive phases of the flares and moved with speeds ranging from 30 to 50 km s1^{-1}. These features were located near the previously reported compact acoustic \cite{Donea05} and seismic sources \cite{Zharkova07}. We examine the origin of these features and their relationship with various aspects of the flares, {\it viz.}, hard X-ray emission sources and flare kernels observed at different layers - (i) photosphere (white-light continuum), (ii) chromosphere (Hα\alpha 6563\AA), (iii) temperature minimum region (UV 1600\AA), and (iv) transition region (UV 284\AA).Comment: 26 pages, 13 figures, 2 tables, accepted for publication in Solar Physic

    Homocysteine in dogs with systemic inflammatory response syndrome

    Get PDF
    OBJECTIVES - To compare serum concentrations of homocysteine (Hcy) in dogs fitting the criteria for the systemic inflammatory response syndrome (SIRS) and healthy dogs, and compare these values to commonly measured B-vitamins. METHODS – Study dogs were classified into noninfectious SIRS or sepsis groups and blood was drawn on Day 1 of the patient’s hospitalization for the measurement of Hcy, folate and cobalamin concentrations. Hcy was measured in 51 clinically normal dogs to serve as the control group. RESULTS - A statistically significant difference was found between the Hcy concentrations of the healthy group when compared to noninfectious SIRS and sepsis groups. Hcy values were not correlated with folate, cobalamin or APPLEfast severity scores. Hcy concentrations were significantly lower in sick dogs when compared to the control group, which is dissimilar to the human population. CLINICAL SIGNIFCANCE - The clinical significance of Hcy changes in critically ill dogs is currently unknown.http://aac.asm.orghb2014ab201

    Improving the rheometry of rubberized bitumen: experimental and computation fluid dynamics studies

    Get PDF
    Multi-phase materials are common in several fields of engineering and rheological measurements are intensively adopted for their development and quality control. Unfortunately, due to the complexity of these materials, accurate measurements can be challenging. This is the case of bitumen-rubber blends used in civil engineering as binders for several applications such as asphalt concrete for road pavements but recently also for roofing membranes. These materials can be considered as heterogeneous blends of fluid and particles with different densities. Due to this nature the two components tends to separate and this phenomenon can be enhanced with inappropriate design and mixing. This is the reason behind the need of efficient dispersion and distribution during their manufacturing and it also explains while realtime viscosity measurements could provide misleading results. To overcome this problem, in a previous research effort, a Dual Helical Impeller (DHI) for a Brookfield viscometer was specifically designed, calibrated and manufactured. The DHI showed to provide a more stable trend of measurements and these were identified as being ‘‘more realistic” when compared with those obtained with standard concentric cylinder testing geometries, over a wide range of viscosities. However, a fundamental understanding of the reasons behind this improvement is lacking and this paper aims at filling these gaps. Hence, in this study a tailored experimental programme resembling the bitumen-rubber system together with a bespoke Computational Fluid Dynamics (CFD) model are used to provide insights into DHI applicability to perform viscosity measurements with multiphase fluids as well as to validate its empirical calibration procedure. A qualitative comparison between the laboratory results and CFD simulations proved encouraging and this was enhanced with quantitative estimations of the mixing efficiency of both systems. The results proved that CFD model is capable of simulating these systems and the obtained simulations gave insights into the flow fields created by the DHI. It is now clear that DHI uses its inner screw to create a vertical dragging of particles within a fluid of lower density, while the outer screw transports the suspended particles down. This induced flow helps keeping the test sample less heterogeneous and this in turns allows recording more stable viscosity measurements

    Pharmacokinetic Modelling of Efavirenz, Atazanavir, Lamivudine and Tenofovir in the Female Genital Tract of HIV-Infected Pre-Menopausal Women

    Get PDF
    A previously published study of antiretroviral pharmacokinetics in the female genital tract of HIV-infected women demonstrated differing degrees of female genital tract penetration among antiretrovirals. These blood plasma (BP) and cervicovaginal fluid (CVF) data were co-modelled for four antiretrovirals with varying CVF exposures

    Differential penetration of raltegravir throughout gastrointestinal tissue: implications for eradication and cure

    Get PDF
    To investigate the concentration of the integrase strand inhibitor raltegravir (RAL) throughout gastrointestinal (GI) tissue, especially gutassociated lymphoid tissue (GALT), as an adjunct to current prevention and cure strategies

    Expression of Six Drug Transporters in Vaginal, Cervical, and Colorectal Tissues: Implications for Drug Disposition in HIV Prevention

    Get PDF
    Effective antiretroviral (ARV)-based HIV prevention strategies require optimizing drug exposure in mucosal tissues; yet factors influencing mucosal tissue disposition remain unknown. We hypothesized drug transporter expression in vaginal, cervical, and colorectal tissues is a contributing factor and selected 3 efflux (ABCB1/MDR1, ABCC2/MRP2, ABCC4/MRP4) and 3 uptake (SLC22A6/OAT1, SLC22A8/OAT3, SLCO1B1/OATP1B1) transporters to further investigate based on their affinity for 2 ARVs central to prevention (tenofovir, maraviroc). Tissue was collected from 98 donors. mRNA and protein expression were quantified using qPCR and immunohistochemistry (IHC). Hundred percent of tissues expressed efflux transporter mRNA. IHC localized them to the epithelium and/or submucosa. Multivariable analysis adjusted for age, smoking, and co-medications revealed significant (P  colorectal; vaginal ABCC2 2.9-fold > colorectal; colorectal ABCC4 2.0-fold > cervical). In contrast, uptake transporter mRNA was expressed in <25% of tissues. OAT1 protein was detected in 0% of female genital tissues and in 100% of colorectal tissues, but only in rare epithelial cells. These data support clinical findings of higher maraviroc and tenofovir concentrations in rectal tissue compared to vaginal or cervical tissue after oral dosing. Quantifying mucosal transporter expression and localization can facilitate ARV selection to target these tissues
    corecore