103 research outputs found
Why, When and How Should Clinicians Use Physiology in Patients with Acute Coronary Syndromes?
Current data support the use of coronary physiology in patients with acute coronary syndrome (ACS). In patients with ST-elevation MI, the extent of myocardial damage and microvascular dysfunction create a complex conundrum to assimilate when considering clinical management and risk stratification. In this setting, the index of microcirculatory resistance emerged as an accurate tool to identify patients at risk of suboptimal myocardial reperfusion after primary percutaneous coronary intervention who may benefit from novel adjunctive therapies. In the context of non-ST-elevation ACS, coronary physiology should be carefully interpreted and often integrated with intracoronary imaging, especially in cases of ambiguous culprit lesion. Conversely, the functional assessment of bystander coronary disease is favoured by the available evidence, aiming to achieve complete revascularisation. Based on everyday clinical scenarios, the authors illustrate the available evidence and provide recommendations for the functional assessment of infarct-related artery and non-culprit lesions in patients with ACS
Angiography-derived index of microcirculatory resistance as a novel, pressure-wire-free tool to assess coronary microcirculation in ST elevation myocardial infarction
Immediate assessment of coronary microcirculation during treatment of ST elevation myocardial infarction (STEMI) may facilitate patient stratification for targeted treatment algorithms. Use of pressure-wire to measure the index of microcirculatory resistance (IMR) is possible but has inevitable practical restrictions. We aimed to develop and validate angiography-derived index of microcirculatory resistance (IMRangio) as a novel and pressure-wire-free index to facilitate assessment of the coronary microcirculation. 45 STEMI patients treated with primary percutaneous coronary intervention (pPCI) were enrolled. Immediately before stenting and at completion of pPCI, IMR was measured within the infarct related artery (IRA). At the same time points, 2 angiographic views were acquired during hyperaemia to measure quantitative flow ratio (QFR) from which IMRangio was derived. In a subset of 15 patients both IMR and IMRangio were also measured in the non-IRA. Patients underwent cardiovascular magnetic resonance imaging (CMR) at 48 h for assessment of microvascular obstruction (MVO). IMRangio and IMR were significantly correlated (rho: 0.85, p < 0.001). Both IMR and IMRangio were higher in the IRA rather than in the non-IRA (p = 0.01 and p = 0.006, respectively) and were higher in patients with evidence of clinically significant MVO (> 1.55% of left ventricular mass) (p = 0.03 and p = 0.005, respectively). Post-pPCI IMRangio presented and area under the curve (AUC) of 0.96 (CI95% 0.92-1.00, p < 0.001) for prediction of post-pPCI IMR > 40U and of 0.81 (CI95% 0.65-0.97, p < 0.001) for MVO > 1.55%. IMRangio is a promising tool for the assessment of coronary microcirculation. Assessment of IMR without the use of a pressure-wire may enable more rapid, convenient and cost-effective assessment of coronary microvascular function
Ultrasound- Versus Fluoroscopy-Guided Strategy for Transfemoral Transcatheter Aortic Valve Replacement Access: A Systematic Review and Meta-Analysis
Background:Access site vascular and bleeding complications remain problematic for patients undergoing transcatheter aortic valve replacement (TAVR). Ultrasound-guided transfemoral access approach has been suggested as a technique to reduce access site complications, but there is wide variation in adoption in TAVR. We performed a systematic review and meta-analysis to compare access site vascular and bleeding complications according to the Valve Academic Research Consortium-2 classification following the use of either ultrasound- or conventional fluoroscopy-guided transfemoral TAVR access.Methods:Medline, Embase, Web of Science, and The Cochrane Library were searched to November 2020 for studies comparing ultrasound- and fluoroscopy-guided access for transfemoral TAVR. A priori defined primary outcomes were extracted: (1) major, (2) minor, and (3) major and minor (total) access site vascular complications and (4) life-threatening/major, (5) minor, and (6) life-threatening, major, and minor (total) access site bleeding complications.Results:Eight observational studies (n=3875) were included, with a mean participant age of 82.8 years, STS score 5.81, and peripheral vascular disease in 23.5%. An ultrasound-guided approach was significantly associated with a reduced risk of total (Mantel-Haenszel odds ratio [MH-OR], 0.50 [95% CI, 0.35–0.73]), major (MH-OR, 0.51 [95% CI, 0.35–0.74]), and minor (MH-OR, 0.59 [95% CI, 0.38–0.91]) access site vascular complications. Ultrasound guidance was also significantly associated with total access site bleeding complications (MH-OR, 0.59 [95% CI, 0.39–0.90]). The association remained significant in sensitivity analyses of maximally adjusted minor and total vascular access site complications (MH-OR, 0.51 [95% CI, 0.29–0.90]; MH-OR, 0.44 [95% CI, 0.20–0.99], respectively).Conclusions:In the absence of randomized studies, our data suggests a potential benefit for ultrasound guidance to obtain percutaneous femoral access in TAVR
2024 Recommendations for Validation of Noninvasive Arterial Pulse Wave Velocity Measurement Devices
BACKGROUND: Arterial stiffness, as measured by arterial pulse wave velocity (PWV), is an established biomarker for cardiovascular risk and target-organ damage in individuals with hypertension. With the emergence of new devices for assessing PWV, it has become evident that some of these devices yield results that display significant discrepancies compared with previous devices. This discrepancy underscores the importance of comprehensive validation procedures and the need for international recommendations. METHODS: A stepwise approach utilizing the modified Delphi technique, with the involvement of key scientific societies dedicated to arterial stiffness research worldwide, was adopted to formulate, through a multidisciplinary vision, a shared approach to the validation of noninvasive arterial PWV measurement devices. RESULTS: A set of recommendations has been developed, which aim to provide guidance to clinicians, researchers, and device manufacturers regarding the validation of new PWV measurement devices. The intention behind these recommendations is to ensure that the validation process can be conducted in a rigorous and consistent manner and to promote standardization and harmonization among PWV devices, thereby facilitating their widespread adoption in clinical practice. CONCLUSIONS: It is hoped that these recommendations will encourage both users and developers of PWV measurement devices to critically evaluate and validate their technologies, ultimately leading to improved consistency and comparability of results. This, in turn, will enhance the clinical utility of PWV as a valuable tool for assessing arterial stiffness and informing cardiovascular risk stratification and management in individuals with hypertension
Twenty-Four-Hour Central (Aortic) Systolic Blood Pressure: Reference Values and Dipping Patterns in Untreated Individuals.
Central (aortic) systolic blood pressure (cSBP) is the pressure seen by the heart, the brain, and the kidneys. If properly measured, cSBP is closer associated with hypertension-mediated organ damage and prognosis, as compared with brachial SBP (bSBP). We investigated 24-hour profiles of bSBP and cSBP, measured simultaneously using Mobilograph devices, in 2423 untreated adults (1275 women; age, 18-94 years), free from overt cardiovascular disease, aiming to develop reference values and to analyze daytime-nighttime variability. Central SBP was assessed, using brachial waveforms, calibrated with mean arterial pressure (MAP)/diastolic BP (cSBPMAP/DBPcal), or bSBP/diastolic blood pressure (cSBPSBP/DBPcal), and a validated transfer function, resulting in 144 509 valid brachial and 130 804 valid central measurements. Averaged 24-hour, daytime, and nighttime brachial BP across all individuals was 124/79, 126/81, and 116/72 mm Hg, respectively. Averaged 24-hour, daytime, and nighttime values for cSBPMAP/DBPcal were 128, 128, and 125 mm Hg and 115, 117, and 107 mm Hg for cSBPSBP/DBPcal, respectively. We pragmatically propose as upper normal limit for 24-hour cSBPMAP/DBPcal 135 mm Hg and for 24-hour cSBPSBP/DBPcal 120 mm Hg. bSBP dipping (nighttime-daytime/daytime SBP) was -10.6 % in young participants and decreased with increasing age. Central SBPSBP/DBPcal dipping was less pronounced (-8.7% in young participants). In contrast, cSBPMAP/DBPcal dipping was completely absent in the youngest age group and less pronounced in all other participants. These data may serve for comparison in various diseases and have potential implications for refining hypertension diagnosis and management. The different dipping behavior of bSBP versus cSBP requires further investigation
Anticoagulation Treatment in Venous Thromboembolism: Options and Optimal Duration
Venous thromboembolism (VTE), clinically presented as deep-vein thrombosis (DVT) or pulmonary embolism (PE), constitutes a major global healthcare concern with severe complications, long-term morbidity, and mortality. Although several clinical, genetic, and acquired risk factors for VTE have been identified, the molecular pathophysiology and mechanisms of disease progression remain poorly understood. Anticoagulation has been the cornerstone of therapy for decades, but data is sparse regarding primary and secondary VTE prevention, as well as optimal therapy duration. In this review, we discuss the role of factor Xa in the coagulation cascade and the different choices of anticoagulation therapy based on patients’ predisposing risk factors and risk of event recurrence. Further, we compare newer agents to traditional anticoagulation treatment based on the most recent studies and guidelines. © 2022 Bentham Science Publishers
- …