5,504 research outputs found
A Mid-Infrared Galaxy Atlas (MIGA)
A mid-infrared atlas of part of the Galactic plane () has been constructed using HIRES processed infrared
data to provide a mid-infrared data set for the Canadian Galactic Plane Survey
(CGPS). The addition of this data set to the CGPS will enable the study of the
emission from the smallest components of interstellar dust at an angular
resolution comparable to that of the radio, millimetre, and far-infrared data
in the CGPS. The Mid-Infrared Galaxy Atlas (MIGA) is a mid-infrared (12 m
and 25 m) counterpart to the far-infrared IRAS Galaxy Atlas (IGA), and
consists of resolution enhanced ( resolution) HIRES images along
with ancillary maps. This paper describes the processing and characteristics of
the atlas, the cross-beam simulation technique used to obtain high-resolution
ratio maps, and future plans to extend both the IGA and MIGA.Comment: 38 pages (including 15 tables), 13 figures (8 dithered GIF and 5
EPS). Submitted to Astrophysical Journal Supplement Series. A preprint with
higher resolution figures is available at
http://www.cita.utoronto.ca/~kerton/publications.htm
Prevalence and risk factors for mast cell tumours in dogs in England
BACKGROUND: Mast cell tumour (MCT) appears to be a frequent tumour type in dogs, though there is little published in relation to its frequency in dogs in the UK. The current study aimed to investigate prevalence and risk factors for MCTs in dogs attending English primary-care veterinary practices. METHODS: Electronic patient records from practices participating in the VetCompass animal surveillance project between July 2007 and June 2013 were searched for MCT diagnosis. Various search terms and standard diagnostic terms (VeNom codes) identified records containing MCT diagnoses, which were evaluated against clinical criteria for inclusion to the study. MCT prevalence for the entire dataset and specific breed types were calculated. Descriptive statistics characterised MCT cases and multivariable logistic regression methods evaluated risk factors for association with MCT (Pâ<â0.05). RESULTS: Within a population of 168,636 dogs, 453 had MCT, yielding a prevalence of 0.27% (95% confidence interval (CI) 0.24% - 0.29%). The highest breed type specific prevalences were for the Boxer at 1.95% (95% CI 1.40% - 2.51%), Golden Retriever at 1.39% (0.98% - 1.81%) and Weimaraner at 0.85% (95% CI 0.17% to 1.53%). Age, insurance status, neuter status, weight and breed type were associated with MCT diagnosis. Of dogs of specific breed type, the Boxer, Pug and Staffordshire Bull Terrier showed greater odds of MCT diagnosis compared with crossbred dogs. Conversely, the German Shepherd Dog, Border Collie, West Highland White Terrier, Springer Spaniel and Cocker Spaniel had reduced odds of MCT diagnosis compared with crossbred dogs. No association was found between MCT diagnosis and sex. CLINICAL SIGNIFICANCE: This study highlights a clinically significant prevalence of MCT and identifies specific breed types with predisposition to MCT, potentially aiding veterinarian awareness and facilitating diagnosis
Polarization dependent photoionization cross-sections and radiative lifetimes of atomic states in Ba
The photoionization cross-sections of two even-parity excited states, and , of atomic Ba at the ionization-laser wavelength of
556.6 nm were measured. We found that the total cross-section depends on the
relative polarization of the atoms and the ionization-laser light. With
density-matrix algebra, we show that, in general, there are at most three
parameters in the photoionization cross-section. Some of these parameters are
determined in this work. We also present the measurement of the radiative
lifetime of five even-parity excited states of barium.Comment: 11 pages, 7 figure
Variation in Heat Transfer During Transient Heating of a Hemisphere at a Mach Number of 2
Convective heat-transfer tests were made on a 5-inch-diameter hemisphere to determine the variation of Stanton number with the ratio of wall temperature to total temperature. The tests were made at a nominal Mach number of 2 for stagnation temperatures of 760 deg R, 1,030 deg R, and 1,380 deg R. The model was constructed so that radiation effects and also streamwise conduction effects within the model skin were minimized. The results of the tests verified that these effects were small. Tests which were made with different masses of air inside the model to check for conduction effects to the internal air cavity showed these effects to be negligible. For laminar flow on the hemisphere, the Stanton number remained essentially constant as the ratio of wall temperature to total temperature increased. However, for fully established turbulent flow, the Stanton number at some stations decreased on the order of 50 percent as the ratio of wall temperature to total temperature increased. A theory which agreed fairly well with the trend of this decrease is shown for comparison
Ultrastable lasers based on vibration insensitive cavities
We present two ultra-stable lasers based on two vibration insensitive cavity
designs, one with vertical optical axis geometry, the other horizontal.
Ultra-stable cavities are constructed with fused silica mirror substrates,
shown to decrease the thermal noise limit, in order to improve the frequency
stability over previous designs. Vibration sensitivity components measured are
equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which
shows significant improvement over previous studies. We have tested the very
low dependence on the position of the cavity support points, in order to
establish that our designs eliminate the need for fine tuning to achieve
extremely low vibration sensitivity. Relative frequency measurements show that
at least one of the stabilized lasers has a stability better than 5.6e-16 at 1
second, which is the best result obtained for this length of cavity.Comment: 8 pages 12 figure
Informal task-sharing practices in inpatient newborn settings in a low-income setting-A task analysis approach.
Aim
To describe the complexity and criticality of neonatal nursing tasks and existing taskâsharing practices to identify tasks that might be safely shared in inpatient neonatal settings.
Design
We conducted a crossâsectional study in a large geographically dispersed sample using the STROBE guidelines.
Methods
We used a task analysis approach to describe the complexity/criticality of neonatal nursing tasks and to explore the nature of task sharing using data from structured, selfâadministered questionnaires. Data was collected between 26th April and 22nd August 2017.
Results
Thirtyâtwo facilities were surveyed between 26th April and 22nd August, 2017. Nearly half (42%, 6/14) of the âmoderately criticalâ and ânot criticalâ (41%, 5/11) tasks were ranked as consuming most of the nurses' time and reported as shared with mothers respectively. Most tasks were reported as shared in the public sector than in the privateânotâforâprofit facilities. This may largely be a response to inadequate nurse staffing, as such, there may be space for considering the future role of health care assistants
Unusually large polarizabilities and "new" atomic states in Ba
Electric polarizabilities of four low-J even-parity states and three low-J
odd-parity states of atomic barium in the range to $36,000\
^{-1}6s8p
^3P_{0,2}$ is suggested.Comment: 29 pages, 12 figure
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
We demonstrate the use of a fiber-based femtosecond laser locked onto an
ultra-stable optical cavity to generate a low-noise microwave reference signal.
Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a
Ti:Sapphire-based optical frequency comb system exhibit a stability about
between 1 s and 10 s. The microwave signal from the fiber
system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium
fountain clock. The resulting clock system is compared to the CSO and exhibits
a stability of . Our continuously operated
fiber-based system therefore demonstrates its potential to replace the CSO for
atomic clocks with high stability in both the optical and microwave domain,
most particularly for operational primary frequency standards.Comment: 3 pages, 3 figure
- âŠ