334 research outputs found
Mercury cadmium telluride photodiode
High speed (Hg,Cd)Te photodiode detectors sensitive to 10.6 microns radiation with operating temperature range of 77 to 90
Noise of the Harrier in vertical landing and takeoff
The noise of the Harrier AV8C aircraft in vertical takeoff and landing was measured 100 feet to the side of the aircraft where jet noise dominates. The noise levels were quite high - up to 125 dB overall sound level at 100 feet. The increased noise due to jet impingement on the ground is presented as a function of jet height to diameter ratio. The impingement noise with the aircraft close to the ground was 14 to 17 dB greater than noise from a free jet. Results are compared with small-scale jet impingement data acquired elsewhere. The agreement between small-scale and full-scale noise increase in ground effect is fairly good except with the jet close to the ground. It is proposed that differences in the jet Reynolds numbers and the resultant character of the jets may be partially responsible for the disparity in the full-scale and small-scale jet impingement noise. The difference between single-jet impingement and multiple-jet impingement may also have been responsible for the small-scale and full-scale disagreement
Calibration of the Ames Anechoic Facility. Phase 1: Short range plan
A calibration was made of the acoustic and aerodynamic characteristics of a small, open-jet wind tunnel in an anechoic room. The jet nozzle was 102 mm diameter and was operated subsonically. The anechoic-room dimensions were 7.6 m by 5.5 m by 3.4 m high (wedge tip to wedge tip). Noise contours in the chamber were determined by various jet speeds and exhaust collector positions. The optimum nozzle/collector separation from an acoustic standpoint was 2.1 m. Jet velocity profiles and turbulence levels were measured using pressure probes and hot wires. The jet was found to be symmetric, with no unusual characteristics. The turbulence measurements were hampered by oil mist contamination of the airflow
Electromagnetic response of a static vortex line in a type-II superconductor : a microscopic study
The electromagnetic response of a pinned Abrikosov fluxoid is examined in the
framework of the Bogoliubov-de Gennes formalism. The matrix elements and the
selection rules for both the single photon (emission - absorption) and two
photon (Raman scattering) processes are obtained. The results reveal striking
asymmetries: light absorption by quasiparticle pair creation or single
quasiparticle scattering can occur only if the handedness of the incident
radiation is opposite to that of the vortex core states. We show how these
effects will lead to nonreciprocal circular birefringence, and also predict
structure in the frequency dependence of conductivity and in the differential
cross section of the Raman scattering.Comment: 14 pages (RevTex
Population-Based Rates of Revision of Primary Total Hip Arthroplasty: A Systematic Review
Background: Most research on failure leading to revision total hip arthroplasty (THA) is reported from single centers. We searched PubMed between January 2000 and August 2010 to identify population- or community-based studies evaluating ten-year revision risks. We report ten-year revision risk using the Kaplan-Meier method, stratifying by age and fixation technique. Results: Thirteen papers met the inclusion criteria. Cemented prostheses had Kaplan-Meier estimates of revision-free implant survival of ten years ranging from 88 % to 95%; uncemented prostheses had Kaplan-Meier estimates from 80 % to 85%. Estimates ranged from 72 % to 86 % in patients less than 60 years old and from 90 to 96 % in older patients. Conclusion: Data reported from national registries suggest revision risks of 5 to 20 % ten years following primary THA. Revision risks are lower in older THA recipients. Uncemented implants may have higher ten-year rates of revision, regardless of age
Regulation of macrophage eicosanoid production by hydroperoxy-and hydroxy-eicosatetraenoic acids
Systematic review of tonsil surgery quality registers and introduction of the Nordic Tonsil Surgery Register Collaboration
Surgical quality registers provide tools to measure and improve the outcome of surgery. International register collaboration creates an opportunity to assess and critically evaluate national practices, and increases the size of available datasets. Even though millions of yearly tonsillectomies and tonsillotomies are performed worldwide, clinical practices are variable and inconsistency of evidence regarding the best clinical practice exists. The need for quality improvement actions is evident. We aimed to systematically investigate the existing tonsil surgery quality registers found in the literature, and to provide a thorough presentation of the planned Nordic Tonsil Surgery Register Collaboration. A systematic literature search of MEDLINE and EMBASE databases (from January 1990 to December 2016) was conducted to identify registers, databases, quality improvement programs or comprehensive audit programs addressing tonsil surgery. We identified two active registers and three completed audit programs focusing on tonsil surgery quality registration. Recorded variables were fairly similar, but considerable variation in coverage, number of operations included and length of time period for inclusion was discovered. Considering tonsillectomies and tonsillotomies being among the most commonly performed surgical procedures in otorhinolaryngology, it is surprising that only two active registers could be identified. We present a Nordic Tonsil Surgery Register Collaboration-an international tonsil surgery quality register project aiming to provide accurate benchmarks and enhance the quality of tonsil surgery in Denmark, Finland, Norway and Sweden.Peer reviewe
The Harris hip score: Do ceiling effects limit its usefulness in orthopedics?: A systematic review
The Harris hip score (HHS), a disease-specific health status scale that is frequently used to measure the outcome of total hip arthroplasty, has never been validated properly. A questionnaire is suitable only when all 5 psychometric properties are of sufficient quality. We questioned the usefulness of the HHS by investigating its content validity. We performed a systematic review based on a literature search in PubMed, Embase, and the Cochrane Library for descriptive studies published in 2007. 54 studies (59 patient groups) met our criteria and were included in the data analysis. To determine the content validity, we calculated the ceiling effect (percentage) for each separate study and we pooled data to measure the weighted mean. A subanalysis of indications for THA was performed to differentiate the populations for which the HHS would be suitable and for which it would not. A ceiling effect of 15% or less was considered to be acceptable. Over half the studies (31/59) revealed unacceptable ceiling effects. Pooled data across the studies included (n = 6,667 patients) suggested ceiling effects of 20% (95%CI: 18-22). Ceiling effects were greater (32%, 95%CI:12-52) in those patients undergoing hip resurfacing arthroplasty. Although the Harris hip score is widely used in arthroplasty research on outcomes, ceiling effects are common and these severely limit its validity in this field of researc
Neutron decay of deep-hole states populated by the <sup>208</sup>Pb(<sup>3</sup>He,α)<sup>207</sup>Pb reaction at 102 MeV
Neutron decay of excited hole states populated by the 208Pb(3He,α) reaction at an energy of 102 MeV has been investigated. The α-particles were analysed in a magnetic spectrograph positioned at 1.4° and detected with a multi-wire drift chamber. Excitation energies in 207Pb up to 25 MeV were studied. An array of neutron detectors was positioned around the target at angles ranging from 68° to 209°. The neutron data were analysed in terms of decay into final states, using statistical-model calculations as a tool to extract non-statistical decay.</p
- …