4,069 research outputs found
Characterisation of Hybrid Pixel Detectors with capacitive charge division
In order to fully exploit the physics potential of the future high energy e+
e- linear collider, a Vertex Tracker providing high resolution track
reconstruction is required. Hybrid pixel sensors are an attractive technology
due to their fast read-out capabilities and radiation hardness. A novel pixel
detector layout with interleaved cells between the readout nodes has been
developed to improve the single point resolution. The results of the
characterisation of the first processed prototypes are reported.Comment: 5 pages, 2 figures, presented at LCWS2000, Linear Collider Workshop,
October 24-28 2000, Fermi National Accelerator Laboratory, Batavia, Illinois,
U.S.A. Proceedings to be published by the American Institute of Physic
Performances of multi-gap timing RPCs for relativistic ions in the range Z=1-6
We present the performance of Multi-gap timing RPCs under irradiation by
fully stripped relativistic ions (gamma*beta=2.7, Z=1-6). A time resolution of
80 ps at high efficiency has been obtained by just using standard `off the
shelf' 4-gap timing RPCs from the new HADES ToF wall. The resolution worsened
to 100 ps for ~ 1 kHz/cm2 proton flux and for ~ 100 Hz/cm2 Carbon flux. The
chambers were operated at a standard field of E=100 kV/cm and showed a high
stability during the experiment, supporting the fact that RPCs are a convenient
choice when accommodating a very broad range of ionizing particles is needed.
The data provides insight in the region of very highly ionizing particles (up
to x 36 mips) and can be used to constrain the existing avalanche and
Space-Charge models far from the usual `mip valley'. The implications of these
results for the general case of detection based on secondary processes (n,
gamma) resulting in highly ionizing particles with characteristic energy
distributions will be discussed, together with the nature of the time-charge
correlation curve.Comment: 31 pages, 19 figures, submitted to JINS
The Lambek calculus with iteration: two variants
Formulae of the Lambek calculus are constructed using three binary
connectives, multiplication and two divisions. We extend it using a unary
connective, positive Kleene iteration. For this new operation, following its
natural interpretation, we present two lines of calculi. The first one is a
fragment of infinitary action logic and includes an omega-rule for introducing
iteration to the antecedent. We also consider a version with infinite (but
finitely branching) derivations and prove equivalence of these two versions. In
Kleene algebras, this line of calculi corresponds to the *-continuous case. For
the second line, we restrict our infinite derivations to cyclic (regular) ones.
We show that this system is equivalent to a variant of action logic that
corresponds to general residuated Kleene algebras, not necessarily
*-continuous. Finally, we show that, in contrast with the case without division
operations (considered by Kozen), the first system is strictly stronger than
the second one. To prove this, we use a complexity argument. Namely, we show,
using methods of Buszkowski and Palka, that the first system is -hard,
and therefore is not recursively enumerable and cannot be described by a
calculus with finite derivations
The Straw Tube Trackers of the PANDA Experiment
The PANDA experiment will be built at the FAIR facility at Darmstadt
(Germany) to perform accurate tests of the strong interaction through bar pp
and bar pA annihilation's studies. To track charged particles, two systems
consisting of a set of planar, closed-packed, self-supporting straw tube layers
are under construction. The PANDA straw tubes will have also unique
characteristics in term of material budget and performance. They consist of
very thin mylar-aluminized cathodes which are made self-supporting by means of
the operation gas-mixture over-pressure. This solution allows to reduce at
maximum the weight of the mechanical support frame and hence the detector
material budget. The PANDA straw tube central tracker will not only reconstruct
charged particle trajectories, but also will help in low momentum (< 1 GeV)
particle identification via dE/dx measurements. This is a quite new approach
that PANDA tracking group has first tested with detailed Monte Carlo
simulations, and then with experimental tests of detector prototypes. This
paper addresses the design issues of the PANDA straw tube trackers and the
performance obtained in prototype tests.Comment: 7 pages,16 figure
Revascularization of Chronic Hibernating Myocardium Stimulates Myocyte Proliferation and Partially Reverses Chronic Adaptations to Ischemia
AbstractBackgroundThe time course and extent of recovery after revascularization of viable dysfunctional myocardium are variable. Although fibrosis is a major determinant, myocyte structural and molecular remodeling may also play important roles.ObjectivesThis study sought to determine whether persistent myocyte loss and/or irreversibility of protein changes that develop in hibernating myocardium have an impact on functional recovery in the absence of infarction.MethodsSwine implanted with a chronic left anterior descending artery (LAD) stenosis to produce hibernating myocardium underwent percutaneous revascularization, with serial functional recovery evaluated for 1 month (n = 12). Myocardial tissue was evaluated to assess myocyte size, nuclear density, and proliferation indexes in comparison with those of normal animals and nonrevascularized controls. Proteomic analysis by 2-dimensional differential in-gel electrophoresis was used to determine the reversibility of molecular adaptations of hibernating myocytes.ResultsAt 3 months, physiological features of hibernating myocardium were confirmed, with depressed LAD wall thickening and no significant infarction. Revascularization normalized LAD flow reserve, with no immediate change in LAD wall thickening. Regional LAD wall thickening slowly improved but remained depressed 1 month post–percutaneous coronary intervention. Surprisingly, revascularization was associated with histological evidence of myocytes re-entering the growth phase of the cell cycle and increases in the number of c-Kit+ cells. Myocyte nuclear density returned to normal, whereas regional myocyte hypertrophy regressed. Proteomic analysis demonstrated heterogeneous effects of revascularization. Up-regulated stress and cytoskeletal proteins normalized, whereas reduced contractile and metabolic proteins persisted.ConclusionsDelayed recovery of hibernating myocardium in the absence of scar may reflect persistent reductions in the amounts of contractile and metabolic proteins. Although revascularization appeared to stimulate myocyte proliferation, the persistence of small immature myocytes may have contributed to delayed functional recovery
Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph
Recent tests of a single module of the Jagiellonian Positron Emission
Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips
have proven its applicability for the detection of annihilation quanta (0.511
MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved
resolution is almost by a factor of two better with respect to the current
TOF-PET detectors and it can still be improved since, as it is shown in this
article, the intrinsic limit of time resolution for the determination of time
of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much
lower. As the major point of the article, a method allowing to record
timestamps of several photons, at two ends of the scintillator strip, by means
of matrix of silicon photomultipliers (SiPM) is introduced. As a result of
simulations, conducted with the number of SiPM varying from 4 to 42, it is
shown that the improvement of timing resolution saturates with the growing
number of photomultipliers, and that the 2 x 5 configuration at two ends
allowing to read twenty timestamps, constitutes an optimal solution. The
conducted simulations accounted for the emission time distribution, photon
transport and absorption inside the scintillator, as well as quantum efficiency
and transit time spread of photosensors, and were checked based on the
experimental results. Application of the 2 x 5 matrix of SiPM allows for
achieving the coincidence resolving time in positron emission tomography of
0.170 ns for 15 cm axial field-of-view (AFOV) and 0.365 ns
for 100 cm AFOV. The results open perspectives for construction of a
cost-effective TOF-PET scanner with significantly better TOF resolution and
larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures
Classification of singular Q-homology planes. I. Structure and singularities
A Q-homology plane is a normal complex algebraic surface having trivial
rational homology. We obtain a structure theorem for Q-homology planes with
smooth locus of non-general type. We show that if a Q-homology plane contains a
non-quotient singularity then it is a quotient of an affine cone over a
projective curve by an action of a finite group respecting the set of lines
through the vertex. In particular, it is contractible, has negative Kodaira
dimension and only one singular point. We describe minimal normal completions
of such planes.Comment: improved results from Ph.D. thesis (University of Warsaw, 2009), 25
pages, to appear in Israel J. Mat
Determination of the b quark mass at the M_Z scale with the DELPHI detector at LEP
An experimental study of the normalized three-jet rate of b quark events with
respect to light quarks events (light= \ell \equiv u,d,s) has been performed
using the CAMBRIDGE and DURHAM jet algorithms. The data used were collected by
the DELPHI experiment at LEP on the Z peak from 1994 to 2000. The results are
found to agree with theoretical predictions treating mass corrections at
next-to-leading order. Measurements of the b quark mass have also been
performed for both the b pole mass: M_b and the b running mass: m_b(M_Z). Data
are found to be better described when using the running mass. The measurement
yields: m_b(M_Z) = 2.85 +/- 0.18 (stat) +/- 0.13 (exp) +/- 0.19 (had) +/- 0.12
(theo) GeV/c^2 for the CAMBRIDGE algorithm. This result is the most precise
measurement of the b mass derived from a high energy process. When compared to
other b mass determinations by experiments at lower energy scales, this value
agrees with the prediction of Quantum Chromodynamics for the energy evolution
of the running mass. The mass measurement is equivalent to a test of the
flavour independence of the strong coupling constant with an accuracy of 7
permil.Comment: 24 pages, 10 figures, Accepted by Eur. Phys. J.
- …