350 research outputs found

    A Low Noise Thermometer Readout for Ruthenium Oxide Resistors

    Get PDF
    The thermometer and thermal control system, for the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) experiment, is described, including the design, testing, and results from the first flight of ARCADE. The noise is equivalent to about 1 Omega or 0.15 mK in a second for the RuO_2 resistive thermometers at 2.7 K. The average power dissipation in each thermometer is 1 nW. The control system can take full advantage of the thermometers to maintain stable temperatures. Systematic effects are still under investigation, but the measured precision and accuracy are sufficient to allow measurement of the cosmic background spectrum. Journal-ref: Review of Scientific Instruments Vol 73 #10 (Oct 2002)Comment: 5 pages text 7 figure

    ARCADE: Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission

    Get PDF
    The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument designed to measure the temperature of the cosmic microwave background at centimeter wavelengths. ARCADE searches for deviations from a blackbody spectrum resulting from energy releases in the early universe. Long-wavelength distortions in the CMB spectrum are expected in all viable cosmological models. Detecting these distortions or showing that they do not exist is an important step for understanding the early universe. We describe the ARCADE instrument design, current status, and future plans.Comment: 12 pages, 6 figures. Proceedings of the Fundamental Physics With CMB workshop, UC Irvine, March 23-25, 2006, to be published in New Astronomy Review

    ARCADE 2 Measurement of the Extra-Galactic Sky Temperature at 3-90 GHz

    Get PDF
    The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an {\it in situ} reference. Systematic errors were greatly reduced by using differential radiometers and cooling all critical components to physical temperatures approximating the CMB temperature. A linear model is used to compare the output of each radiometer to a set of thermometers on the instrument. Small corrections are made for the residual emission from the flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE 2 data alone show an extragalactic rise of 50±750\pm7 mK at 3.3 GHz in addition to a CMB temperature of 2.730±.0042.730\pm .004 K. Combining the ARCADE 2 data with data from the literature shows a background power law spectrum of T=1.26±0.09T=1.26\pm 0.09 [K] (ν/ν0)2.60±0.04(\nu/\nu_0)^{-2.60\pm 0.04} from 22 MHz to 10 GHz (ν0=1\nu_0=1 GHz) in addition to a CMB temperature of 2.725±.0012.725\pm .001 K.Comment: 11 pages 5 figures Submitted to Ap

    The Temperature of the CMB at 10 GHz

    Full text link
    We report the results of an effort to measure the low frequency portion of the spectrum of the Cosmic Microwave Background Radiation (CMB), using a balloon-borne instrument called ARCADE (Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission). These measurements are to search for deviations from a thermal spectrum that are expected to exist in the CMB due to various processes in the early universe. The radiometric temperature was measured at 10 and 30 GHz using a cryogenic open-aperture instrument with no emissive windows. An external blackbody calibrator provides an in situ reference. A linear model is used to compare the radiometer output to a set of thermometers on the instrument. The unmodeled residuals are less than 50 mK peak-to-peak with a weighted RMS of 6 mK. Small corrections are made for the residual emission from the flight train, atmosphere, and foreground Galactic emission. The measured radiometric temperature of the CMB is 2.721 +/- 0.010 K at 10 GHz and 2.694 +/- 0.032 K at 30 GHz.Comment: 8 pages including 5 figures. Submitted to The Astrophysical Journa

    ARCADE 2 Observations of Galactic Radio Emission

    Get PDF
    We use absolutely calibrated data from the ARCADE 2 flight in July 2006 to model Galactic emission at frequencies 3, 8, and 10 GHz. The spatial structure in the data is consistent with a superposition of free-free and synchrotron emission. Emission with spatial morphology traced by the Haslam 408 MHz survey has spectral index beta_synch = -2.5 +/- 0.1, with free-free emission contributing 0.10 +/- 0.01 of the total Galactic plane emission in the lowest ARCADE 2 band at 3.15 GHz. We estimate the total Galactic emission toward the polar caps using either a simple plane-parallel model with csc|b| dependence or a model of high-latitude radio emission traced by the COBE/FIRAS map of CII emission. Both methods are consistent with a single power-law over the frequency range 22 MHz to 10 GHz, with total Galactic emission towards the north polar cap T_Gal = 0.498 +/- 0.028 K and spectral index beta = -2.55 +/- 0.03 at reference frequency 1 GHz. The well calibrated ARCADE 2 maps provide a new test for spinning dust emission, based on the integrated intensity of emission from the Galactic plane instead of cross-correlations with the thermal dust spatial morphology. The Galactic plane intensity measured by ARCADE 2 is fainter than predicted by models without spinning dust, and is consistent with spinning dust contributing 0.4 +/- 0.1 of the Galactic plane emission at 22 GHz.Comment: 10 poges, 9 figures. Submitted to The Astrophysical Journa

    Learners in a Changing Learning Landscape: Reflections from an Instructional Design Perspective

    Get PDF
    Van Merriënboer, J. J. G., & Stoyanov, S. (2008). Learners in a changing learning landscape: Reflections from an instructional design perspective. In J. Visser & M. Visser-Valfrey (Eds.), Learners in a changing learning landscape: Reflections from a dialogue on new roles and expectations (pp. 69-90). Dordrecht, The Netherlands: Springer.Both learners and teachers find themselves in a learning landscape that is rapidly changing, along with fast societal and technological developments. This paper discusses the new learning landscape from an instructional design perspective. First, with regard to what is learned, people more than ever need flexible problem-solving and reasoning skills allowing them to deal with new, unfamiliar problem situations in their professional and everyday life. Second, with regard to the context in which learning takes place, learning in technology-rich, informal and professional 24/7 settings is becoming general practice. And third, with regard to the learners themselves, they can more often be characterized as lifelong learners who are mature, bring relevant prior knowledge, and have very heterogeneous expectations and perceptions of learning. High-quality instructional design research should focus on the question which instructional methods and media-method combinations are effective, efficient and appealing in this new learning landscape. Some innovative instructional methods that meet this requirement are discussed

    Design and Calibration of a Cryogenic Blackbody Calibrator at Centimeter Wavelengths

    Full text link
    We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of a microwave absorber weakly coupled to a superfluid liquid helium bath. Half-wave corrugations viewed 30 deg off axis reduce the return loss below -35 dB. Ruthenium oxide resistive thermometers embedded within the absorber monitor the temperature across the face of the calibrator. The thermal calibration transfers the calibration of a reference thermometer to the flight thermometers using the flight thermometer readout system. Data taken near the superfluid transition in 8 independent calibrations 4 years apart agree within 0.3 mK, providing an independent verification of the thermometer calibration at temperatures near that of the cosmic microwave background.Comment: 5 pages including 5 figures. Submitted to Review of Scientific Instrument

    Detectable Clonal Mosaicism from Birth to Old Age and its Relationship to Cancer

    Get PDF
    Clonal mosaicism for large chromosomal anomalies (duplications, deletions and uniparental disomy) was detected using SNP microarray data from over 50,000 subjects recruited for genome-wide association studies. This detection method requires a relatively high frequency of cells (>5–10%) with the same abnormal karyotype (presumably of clonal origin) in the presence of normal cells. The frequency of detectable clonal mosaicism in peripheral blood is low (<0.5%) from birth until 50 years of age, after which it rises rapidly to 2–3% in the elderly. Many of the mosaic anomalies are characteristic of those found in hematological cancers and identify common deleted regions that pinpoint the locations of genes previously associated with hematological cancers. Although only 3% of subjects with detectable clonal mosaicism had any record of hematological cancer prior to DNA sampling, those without a prior diagnosis have an estimated 10-fold higher risk of a subsequent hematological cancer (95% confidence interval = 6–18)
    corecore