1,237 research outputs found
A Note on the Convergence to Competitive Equilibria in Economies with Moral Hazard
asymmetric information; exclusivity; convergence
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
Athena is a space-based X-ray observatory intended for exploration of the hot
and energetic universe. One of the science instruments on Athena will be the
X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer,
based on a large cryogenic imaging array of Transition Edge Sensors (TES) based
microcalorimeters operating at a temperature of 100mK. The imaging array
consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a
field of view with a diameter of of 5 arc minutes. Multiplexed readout of the
cryogenic microcalorimeter array is essential to comply with the cooling power
and complexity constraints on a space craft. Frequency domain multiplexing has
been under development for the readout of TES-based detectors for this purpose,
not only for the X-IFU detector arrays but also for TES-based bolometer arrays
for the Safari instrument of the Japanese SPICA observatory. This paper
discusses the design considerations which are applicable to optimise the
multiplex factor within the boundary conditions as set by the space craft. More
specifically, the interplay between the science requirements such as pixel
dynamic range, pixel speed, and cross talk, and the space craft requirements
such as the power dissipation budget, available bandwidth, and electromagnetic
compatibility will be discussed
Efficacy and Safety of Direct-Acting Oral Anticoagulants Use in Acute Portal Vein Thrombosis Unrelated to Cirrhosis
In acute portal vein thrombosis (APVT) unrelated to cirrhosis, anticoagulant therapy is classically started with low molecular weight heparin or vitamin K antagonists. New direct-acting oral anticoagulants (DOACs) are used in the treatment of venous thrombosis outside the splanchnic vascular bed, but not in the latter. We report a young female with APVT occurring in a non-cirrhotic liver linked to heterozygosity of factor V-Leiden and prothrombin G20210A gene mutations. Rivaroxaban was started, with total recanalization of the left and partial recanalization of the right portal vein branches, without complications. New DOACs do not need daily subcutaneous injections nor routinely blood coagulation control tests, making its use attractive, eventually increasing patient's compliance. If proved to be safe and effective in the future studies, its use may be extended to PVT treatment. This case shows that rivaroxaban was safe, not only prevented the extension of thrombosis in the portal tract, but also resolved PVT, at least partially.info:eu-repo/semantics/publishedVersio
Advanced code-division multiplexers for superconducting detector arrays
Multiplexers based on the modulation of superconducting quantum interference
devices are now regularly used in multi-kilopixel arrays of superconducting
detectors for astrophysics, cosmology, and materials analysis. Over the next
decade, much larger arrays will be needed. These larger arrays require new
modulation techniques and compact multiplexer elements that fit within each
pixel. We present a new in-focal-plane code-division multiplexer that provides
multiplexing elements with the required scalability. This code-division
multiplexer uses compact lithographic modulation elements that simultaneously
multiplex both signal outputs and superconducting transition-edge sensor (TES)
detector bias voltages. It eliminates the shunt resistor used to voltage bias
TES detectors, greatly reduces power dissipation, allows different dc bias
voltages for each TES, and makes all elements sufficiently compact to fit
inside the detector pixel area. These in-focal-plane code-division multiplexers
can be combined with multi-gigahertz readout based on superconducting
microresonators to scale to even larger arrays.Comment: 8 pages, 3 figures, presented at the 14th International Workshop on
Low Temperature Detectors, Heidelberg University, August 1-5, 2011,
proceedings to be published in the Journal of Low Temperature Physic
Tailoring CD19xCD3-DART exposure enhances T-cells to eradication of B-cell neoplasms.
Many patients with B-cell malignancies can be successfully treated, although tumor eradication is rarely achieved. T-cell-directed killing of tumor cells using engineered T-cells or bispecific antibodies is a promising approach for the treatment of hematologic malignancies. We investigated the efficacy of CD19xCD3 DART bispecific antibody in a broad panel of human primary B-cell malignancies. The CD19xCD3 DART identified 2 distinct subsets of patients, in which the neoplastic lymphocytes were eliminated with rapid or slow kinetics. Delayed responses were always overcome by a prolonged or repeated DART exposure. Both CD4 and CD8 effector cytotoxic cells were generated, and DART-mediated killing of CD4+ cells into cytotoxic effectors required the presence of CD8+ cells. Serial exposures to DART led to the exponential expansion of CD4 + and CD8 + cells and to the sequential ablation of neoplastic cells in absence of a PD-L1-mediated exhaustion. Lastly, patient-derived neoplastic B-cells (B-Acute Lymphoblast Leukemia and Diffuse Large B Cell Lymphoma) could be proficiently eradicated in a xenograft mouse model by DART-armed cytokine induced killer (CIK) cells. Collectively, patient tailored DART exposures can result in the effective elimination of CD19 positive leukemia and B-cell lymphoma and the association of bispecific antibodies with unmatched CIK cells represents an effective modality for the treatment of CD19 positive leukemia/lymphoma
Development of frequency domain multiplexing for the X-ray Integral Field Unit (X-IFU) on the Athena
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of 3840 TESs with a
high quantum efficiency (90 \%) and spectral resolution =2.5 eV
7 keV (2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions 2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.Comment: 8 pages, 4 figures, Proceedings of the SPIE Astronomical
Instrumentation "Space Telescopes and Instrumentation 2014: Ultraviolet to
Gamma Ray
Beneficial effects of spices in food preservation and safety
Spices have been used since ancient times. Although they have been employed mainly as flavoring and coloring agents, their role in food safety and preservation have also been studied in vitro and in vivo. Spices have exhibited numerous health benefits in preventing and treating a wide variety of diseases such as cancer, aging, metabolic, neurological, cardiovascular, and inflammatory diseases. The present review aims to provide a comprehensive summary of the most relevant and recent findings on spices and their active compounds in terms of targets and mode of action; in particular, their potential use in food preservation and enhancement of shelf life as a natural bioingredient
Da Frankenstein ad Asimov: letteratura 'predittiva', robotica e lavoro
Rilettura della documentazione sul tem
- …
