A Digitally Calibrated 12 bits 25 MS/s Pipelined ADC with a 3 input multiplexer for CALICE Integrated Readout
The necessity of full integrated electronics readout for the next ILC ECAL presents many challenges for low power mixed signal design. The analog to digital converter is a critical stage for the system going from the very front-end stages to digital memories. We present here a high speed converter configuration designed to multiplex 3 analog channels through one analog to digital converter. It is a first step for a multiplexed 64 channel design. A CMOS 0.35μm process is used. The dynamic range is 2V over a 3.3V power supply, and the total power dissipation at 25 MHz is approximately 40mW. An analog power management is included to allow a fast switching into a standby mode that reduces the DC power dissipation by a ratio of three orders of magnitude (1/1000)
Experimental study of a liquid Xenon PET prototype module
A detector using liquid Xenon in the scintillation mode is studied for
Positron Emission Tomography (PET). The specific design aims at taking full
advantage of the liquid Xenon properties. It does feature a promising
insensitive to any parallax effect. This work reports on the performances of
the first LXe prototype module, equipped with a position sensitive PMT
operating in the VUV range (178 nm).Comment: Proc. of the 7th International Workshops on Radiation Imaging
Detectors (IWORID-7), Grenoble, France 4-7 July 200
Global unions: chasing the dream or building the reality?
This article takes as its theme the global restructuring of capital and its impact on worker organization. It argues for a reassertion of class in any analysis of global solidarity, and assesses the opportunities and barriers to effective global unionization. Rooted in the UK experience, the article analyzes the impact of the European social dimension on trade unions, before taking the discussion into a global dimension. It concludes by suggesting that there are reasons for cautious optimism in terms of solidarity building, despite difficult historical legacies and the common replacement of action with rhetoric
A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell
A detector using liquid Xenon (LXe) in the scintillation mode is studied for
Positron Emission Tomography (PET) of small animals. Its specific design aims
at taking full advantage of the Liquid Xenon scintillation properties. This
paper reports on energy, time and spatial resolution capabilities of the first
LXe prototype module equipped with a Position Sensitive Photo- Multiplier tube
(PSPMT) operating in the VUV range (178 nm) and at 165 K. The experimental
results show that such a LXe PET configuration might be a promising solution
insensitive to any parallax effect.Comment: 34 pages, 18 pages, to appear in NIM
Experimental results and first 22Na source image reconstruction by two prototype modules in coincidence of a liquid xenon positron emission tomograph for small animal imaging
International audienceA detector with a very specific design using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Two prototype modules equipped with Position Sensitive Photo Multiplier Tubes (PSPMTs) operating in the VUV range (178 nm) and at 165 K were built and studied in coincidence. This paper reports on energy, time and spatial resolution capabilities of this experimental test bench. Furthermore, these experimental results were used to perform the first image reconstruction of a 22Na source placed in the experimental setup
Design of High Dynamic Range Digital to Analog Converters for the Calibration of the CALICE Si-W Ecal readout electronics
The ILC ECAL front-end chip will integrate many functions of the readout electronics including a DAC dedicated to calibration. We present two versions of DAC with respectively 12 and 14 bits, designed in a CMOS 0.35μm process. Both are based on segmented arrays of switched capacitors controlled by a Dynamic Element Matching (DEM) algorithm. A full differential architecture is used, and the amplifiers can be turned into a standby mode reducing the power dissipation. The 12 bit DAC features an INL lower than 0.3 LSB at 5MHz, and dissipates less than 7mW. The 14 bit DAC is an improved version of the 12 bit design
A low power and low signal 4 bit 50MS/s double sampling pipelined ADC for monolithie active pixel sensors
A 4 bit very low power and low incoming signal analog to digital converter (ADC) using a double sampling switched capacitor technique, designed for use in CMOS monolithic active pixels sensor readout, has been implemented in 0.35μm CMOS technology. A non-resetting sample and hold stage is integrated to amplify the incoming signal by 4. This first stage compensates both the amplifier offset effect and the input common mode voltage fluctuations. The converter is composed of a 2.5 bit pipeline stage followed by a 2 bit flash stage. This prototype consists of 4 ADC double-channels; each one is sampling at 50MS/s and dissipates only 2.6mW at 3.3V supply voltage. A bias pulsing stage is integrated in the circuit. Therefore, the analog part is switched OFF or ON in less than 1μs. The size for the layout is 80μm*0.9mm. This corresponds to the pitch of 4 pixel columns, each one is 20μm wide
Critical values for Lawshe's content validity ratio: revisiting the original methods of calculation
YesThe content validity ratio originally proposed by Lawshe is widely used to quantify content validity and yet methods used to calculate the original critical values were never reported. Methods for original calculation of critical values are suggested along with tables of exact binomial probabilities
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by
means of a low intensity 20 GeV/c per nucleon ion beam obtained by
fragmentation of a primary beam of Pb ions. Data have been collected with a
single beam setting, over the range of nuclear charges 2<Z<~45 in various beam
conditions and using different radiators. The charge Z and velocity beta
resolutions have been measured.Comment: 4 pages, contribution to the ICRC 200
The Ring Imaging Cherenkov detector (RICH) of the AMS experiment
The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the
International Space Station (ISS) will be equipped with a proximity focusing
Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and
velocity of the charged cosmic particles. A RICH prototype consisting of 96
photomultiplier units, including a piece of the conical reflector, was built
and its performance evaluated with ion beam data. Preliminary results of the
in-beam tests performed with ion fragments resulting from collisions of a 158
GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported.
The collected data included tests to the final front-end electronics and to
different aerogel radiators. Cherenkov rings for a large range of charged
nuclei and with reflected photons were observed. The data analysis confirms the
design goals. Charge separation up to Fe and velocity resolution of the order
of 0.1% for singly charged particles are obtained.Comment: 29th International Conference on Cosmic Rays (Pune, India
- …