2,519 research outputs found

    Thermochemical analyses of the oxidative vaporization of metals and oxides by oxygen molecules and atoms

    Get PDF
    Equilibrium thermochemical analyses are employed to describe the vaporization processes of metals and metal oxides upon exposure to molecular and atomic oxygen. Specific analytic results for the chromium-, platinum-, aluminum-, and silicon-oxygen systems are presented. Maximum rates of oxidative vaporization predicted from the thermochemical considerations are compared with experimental results for chromium and platinum. The oxidative vaporization rates of chromium and platinum are considerably enhanced by oxygen atoms

    Theoretical and experimental studies of the deposition of Na2So4 from seeded combustion gases

    Get PDF
    Flames in a Mach 0.3 atmospheric pressure laboratory burner rig were doped with sea salt, NaS04, and NaCl, respectively, in an effort to validate theoretical dew point predictions made by a local thermochemical equilibrium (LTCE) method of predicting condensation temperatures of sodium sulfate in flame environments. Deposits were collected on cylindrical platinum targets placed in the combustion products, and the deposition was studied as a function of collector temperature. Experimental deposition onset temperatures checked within experimental error with LTCE-predicted temperatures. A multicomponent mass transfer equation was developed to predict the rate of deposition of Na2SO4(c) via vapor transport at temperatures below the deposition onset temperature. Agreement between maximum deposition rates predicted by this chemically frozen boundary layer (CFBL) theory and those obtained in the seeded laboratory burner experiments is good

    An interstellar precursor mission

    Get PDF
    A mission out of the planetary system, with launch about the year 2000, could provide valuable scientific data as well as test some of the technology for a later mission to another star. Primary scientific objectives for the precursor mission concern characteristics of the heliopause, the interstellar medium, stellar distances (by parallax measurements), low energy cosmic rays, interplanetary gas distribution, and mass of the solar system. Secondary objectives include investigation of Pluto. Candidate science instruments are suggested. Individual spacecraft systems for the mission were considered, technology requirements and problem areas noted, and a number of recommendations made for technology study and advanced development. The most critical technology needs include attainment of 50-yr spacecraft lifetime and development of a long-life NEP system

    Parasite infections in a social carnivore: Evidence of their fitness consequences and factors modulating infection load

    Get PDF
    There are substantial individual differences in parasite composition and infection load in wildlife populations. Few studies have investigated the factors shaping this heterogeneity in large wild mammals or the impact of parasite infections on Darwinian fitness, particularly in juveniles. A host's parasite composition and infection load can be shaped by factors that determine contact with infective parasite stages and those that determine the host's resistance to infection, such as abiotic and social environmental factors, and age. Host–parasite interactions and synergies between coinfecting parasites may also be important. We test predictions derived from these different processes to investigate factors shaping infection loads (fecal egg/oocyte load) of two energetically costly gastrointestinal parasites: the hookworm Ancylostoma and the intracellular Cystoisospora, in juvenile spotted hyenas (Crocuta crocuta) in the Serengeti National Park, in Tanzania. We also assess whether parasite infections curtail survival to adulthood and longevity. Ancylostoma and Cystoisospora infection loads declined as the number of adult clan members increased, a result consistent with an encounter‐reduction effect whereby adults reduced encounters between juveniles and infective larvae, but were not affected by the number of juveniles in a clan. Infection loads decreased with age, possibly because active immune responses to infection improved with age. Differences in parasite load between clans possibly indicate variation in abiotic environmental factors between clan den sites. The survival of juveniles (<365 days old) to adulthood decreased with Ancylostoma load, increased with age, and was modulated by maternal social status. High‐ranking individuals with low Ancylostoma loads had a higher survivorship during the first 4 years of life than high‐ranking individuals with high Ancylostoma loads. These findings suggest that high infection loads with energetically costly parasites such as hookworms during early life can have negative fitness consequences

    Distinct Frontal Ablation Processes Drive Heterogeneous Submarine Terminus Morphology

    Get PDF
    An edited version of this paper was published by AGU. Copyright 2019 American Geophysical Union.Calving and submarine melt drive frontal ablation and sculpt the ice face of marine‐terminating glaciers. However, there are sparse observations of submarine termini, which limit estimates of spatially varying submarine melt. Here we present a detailed survey of a west Greenland glacier to reveal heterogeneity in submarine terminus morphology. We find that the majority of the terminus (~77%) is undercut, driven by calving in the upper water column and submarine melting at depth. The remaining ~23% of the terminus is overcut, driven by calving alone. We use observations of six subglacial discharge outlets, combined with a plume model, to estimate spatially varying discharge fluxes. While small discharge fluxes (<43 m3/s) feed numerous, deeply undercut outlets with subsurface plumes, ~70% of the net subglacial flux emerges at the terminus center, producing a vigorous, surface‐reaching plume. This primary outlet drives large, localized seasonal retreat that exceeds calving rates at secondary outlets

    An asymptotic form of the reciprocity theorem with applications in x-ray scattering

    Full text link
    The emission of electromagnetic waves from a source within or near a non-trivial medium (with or without boundaries, crystalline or amorphous, with inhomogeneities, absorption and so on) is sometimes studied using the reciprocity principle. This is a variation of the method of Green's functions. If one is only interested in the asymptotic radiation fields the generality of these methods may actually be a shortcoming: obtaining expressions valid for the uninteresting near fields is not just a wasted effort but may be prohibitively difficult. In this work we obtain a modified form the reciprocity principle which gives the asymptotic radiation field directly. The method may be used to obtain the radiation from a prescribed source, and also to study scattering problems. To illustrate the power of the method we study a few pedagogical examples and then, as a more challenging application we tackle two related problems. We calculate the specular reflection of x rays by a rough surface and by a smoothly graded surface taking polarization effects into account. In conventional treatments of reflection x rays are treated as scalar waves, polarization effects are neglected. This is a good approximation at grazing incidence but becomes increasingly questionable for soft x rays and UV at higher incidence angles. PACs: 61.10.Dp, 61.10.Kw, 03.50.DeComment: 19 pages, 4 figure

    Weak decays of 4He-Lambda

    Get PDF
    We measured the lifetime and the mesonic and non-mesonic decay rates of the 4He-Lambda hypernucleus. The hypernuclei were created using a 750 MeV/c momentum K- beam on a liquid 4He target by the reaction 4He(K-,pi-)4He-Lambda. The 4He-Lambda lifetime was directly measured using protons from Lambda p -> n p non-mesonic decay (also referred to as proton-stimulated decay) and was found to have a value of tau = 245 +/- 24 ps. The mesonic decay rates were determined from the observed numbers of pi-'s and pi0's as Gamma_pi-/Gamma_tot = 0.270 +/- 0.024 and Gamma_pi0/Gamma_tot = 0.564 +/- 0.036, respectively, and the values of the proton- and neutron-stimulated decay rates were extracted as Gamma_p/Gamma_tot = 0.169 +/- 0.019 and Gamma_n/Gamma_tot <= 0.032 (95% CL), respectively. The effects of final-state interactions and possible 3-body Lambda N N decay contributions were studied in the context of a simple model of nucleon-stimulated decay. Nucleon-nucleon coincidence events were observed and were used in the determination of the non-mesonic branching fractions. The implications of the results of this analysis were considered for the empirical Delta I = 1/2 rule and the decay rates of the 4H-Lambda hypernucleus.Comment: 15 pages, 11 figures, published in PRC, revised content to match published versio

    Measuring vertebrate telomeres: applications and limitations

    Get PDF
    Telomeres are short tandem repeated sequences of DNA found at the ends of eukaryotic chromosomes that function in stabilizing chromosomal end integrity. In vivo studies of somatic tissue of mammals and birds have shown a correlation between telomere length and organismal age within species, and correlations between telomere shortening rate and lifespan among species. This result presents the tantalizing possibility that telomere length could be used to provide much needed information on age, ageing and survival in natural populations where longitudinal studies are lacking. Here we review methods available for measuring telomere length and discuss the potential uses and limitations of telomeres as age and ageing estimators in the fields of vertebrate ecology, evolution and conservation

    Performance of a BGO PET/CT with Higher Resolution PET Detectors

    Get PDF
    A new PET detector block has been designed to replace the standard detector of the Discovery ST PET/CT system. The new detector block is the same size as the original, but consists of an 8/spl times/6 (tangential× axial) matrix of crystals rather than the original 6/spl times/6. The new crystal dimensions are 4.7× 6.3× 30 mm/sup 3/ (tangential× axial× radial). Full PET/CT systems have been built with these detectors (Discovery STE). Most other aspects of the system are identical to the standard Discovery ST, with differences including the low energy threshold for 3D imaging (now 425 keV) and front-end electronics. Initial performance evaluation has been done, including NEMA NU2-2001 tests and imaging of the 3D Hoffman brain phantom and a neck phantom with small lesions. The system sensitivity was 1.90 counts/s/kBq in 2D, and 9.35 counts/s/kBq in 3D. Scatter fractions measured for 2D and 3D, respectively, were 18.6% and 34.5%. In 2D, the peak NEC of 89.9 kcps occurred at 47.0 kBq/cc. In 3D, the peak NEC of 74.3 kcps occurred at 8.5 kBq/cc. Spatial resolution (all expressed in mm FWHM) measured in 2D for 1 cm off-axis source 5.06 transaxial, 5.14 axial and for 10 cm source 5.45 radial, 5.86 tangential, and 6.23 axial. In 3D for 1 cm off-axis source 5.13 transaxial, 5.74 axial, and for 10 cm source 5.92 radial, 5.54 tangential, and 6.16 axial. Images of the brain and neck phantom demonstrate some improvement, compared to measurements on a standard Discovery ST
    corecore