557 research outputs found

    Direct measurement of diurnal polar motion by ring laser gyroscopes

    Get PDF
    We report the first direct measurements of the very small effect of forced diurnal polar motion, successfully observed on three of our large ring lasers, which now measure the instantaneous direction of Earth's rotation axis to a precision of 1 part in 10^8 when averaged over a time interval of several hours. Ring laser gyroscopes provide a new viable technique for directly and continuously measuring the position of the instantaneous rotation axis of the Earth and the amplitudes of the Oppolzer modes. In contrast, the space geodetic techniques (VLBI, SLR, GPS, etc.) contain no information about the position of the instantaneous axis of rotation of the Earth, but are sensitive to the complete transformation matrix between the Earth-fixed and inertial reference frame. Further improvements of gyroscopes will provide a powerful new tool for studying the Earth's interior.Comment: 5 pages, 4 figures, agu2001.cl

    Stabilized High Power Laser for Advanced Gravitational Wave Detectors

    Get PDF
    Second generation gravitational wave detectors require high power lasers with several 100W of output power and with very low temporal and spatial fluctuations. In this paper we discuss possible setups to achieve high laser power and describe a 200W prestabilized laser system (PSL). The PSL noise requirements for advanced gravitational wave detectors will be discussed in general and the stabilization scheme proposed for the Advanced LIGO PSL will be described. Special emphasis will be given to the most demanding power stabilization requiremets and new results (RIN ≀ 4×10-9/surdHz) will be presented

    Single-frequency master-oscillator photonic crystal fiber amplifier with 148 W output power

    Get PDF
    We report on a high-power ytterbium doped photonic crystal fiber amplifier using a single-frequency Nd:YAG non-planar ring oscillator seed source. With a large-mode-area photonic crystal fiber, operation below the threshold of stimulated Brillouin scattering is demonstrated with up to 148 W of continuous-wave output power and a slope efficiency of 75%. At maximum output power the amplified spontaneous emission was suppressed by more than 40 dB and the polarization extinction ratio was better than 22 dB. In order to investigate the overlap of the photonic crystal fiber transverse-mode with a Gaussian fundamental mode, sensitive beam quality measurements with a Fabry-Perot ring-cavity are presented

    Drag Assessment for Boundary Layer Control Schemes with Mass Injection

    Get PDF
    The present study considers uniform blowing in turbulent boundary layers as active flow control scheme for drag reduction on airfoils. The focus lies on the important question of how to quantify the drag reduction potential of this control scheme correctly. It is demonstrated that mass injection causes the body drag (the drag resulting from the stresses on the body) to differ from the wake survey drag (the momentum deficit in the wake of an airfoil), which is classically used in experiments as a surrogate for the former. This difference is related to the boundary layer control (BLC) penalty, an unavoidable drag portion which reflects the effort of a mass-injecting boundary layer control scheme. This is independent of how the control is implemented. With an integral momentum budget, we show that for the present control scheme, the wake survey drag contains the BLC penalty and is thus a measure for the inclusive drag of the airfoil, i.e. the one required to determine net drag reduction. The concept of the inclusive drag is extended also to boundary layers using the von Karman equation. This means that with mass injection the friction drag only is not sufficient to assess drag reduction also in canonical flows. Large Eddy Simulations and Reynolds-averaged Navier-Stokes simulations of the flow around airfoils are utilized to demonstrate the significance of this distinction for the scheme of uniform blowing. When the inclusive drag is properly accounted for, control scenarios previously considered to yield drag reduction actually show drag increase

    Stabilized lasers for advanced gravitational wave detectors

    Get PDF
    Second generation gravitational wave detectors require high power lasers with more than 100 W of output power and with very low temporal and spatial fluctuations. To achieve the demanding stability levels required, low noise techniques and adequate control actuators have to be part of the high power laser design. In addition feedback control and passive noise filtering is used to reduce the fluctuations in the so-called prestabilized laser system (PSL). In this paper, we discuss the design of a 200 W PSL which is under development for the Advanced LIGO gravitational wave detector and will present the first results. The PSL noise requirements for advanced gravitational wave detectors will be discussed in general and the stabilization scheme proposed for the Advanced LIGO PSL will be described

    The Causal Structure of Emotions in Aristotle: Hylomorphism, Causal Interaction between Mind and Body, and Intentionality

    Get PDF
    Recently, a strong hylomorphic reading of Aristotelian emotions has been put forward, one that allegedly eliminates the problem of causal interaction between soul and body. Taking the presentation of emotions in de An. I 1 as a starting point and basic thread, but relying also on the discussion of Rh. II, I will argue that this reading only takes into account two of the four causes of emotions, and that, if all four of them are included into the picture, then a causal interaction of mind and body remains within Aristotelian emotions, independent of how strongly their hylomorphism is understood. Beyond the discussion with this recent reading, the analysis proposed of the fourfold causal structure of emotions is also intended as a hermeneutical starting point for a comprehensive analysis of particular emotions in Aristotle. Through the different causes Aristotle seems to account for many aspects of the complex phenomenon of emotion, including its physiological causes, its mental causes, and its intentional object

    Total Hip Arthroplasty or Hemiarthroplasty for Hip Fracture.

    Get PDF
    BACKGROUND: Globally, hip fractures are among the top 10 causes of disability in adults. For displaced femoral neck fractures, there remains uncertainty regarding the effect of a total hip arthroplasty as compared with hemiarthroplasty. METHODS: We randomly assigned 1495 patients who were 50 years of age or older and had a displaced femoral neck fracture to undergo either total hip arthroplasty or hemiarthroplasty. All enrolled patients had been able to ambulate without the assistance of another person before the fracture occurred. The trial was conducted in 80 centers in 10 countries. The primary end point was a secondary hip procedure within 24 months of follow-up. Secondary end points included death, serious adverse events, hip-related complications, health-related quality of life, function, and overall health end points. RESULTS: The primary end point occurred in 57 of 718 patients (7.9%) who were randomly assigned to total hip arthroplasty and 60 of 723 patients (8.3%) who were randomly assigned to hemiarthroplasty (hazard ratio, 0.95; 95% confidence interval [CI], 0.64 to 1.40; P = 0.79). Hip instability or dislocation occurred in 34 patients (4.7%) assigned to total hip arthroplasty and 17 patients (2.4%) assigned to hemiarthroplasty (hazard ratio, 2.00; 99% CI, 0.97 to 4.09). Function, as measured with the total Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score, pain score, stiffness score, and function score, modestly favored total hip arthroplasty over hemiarthroplasty. Mortality was similar in the two treatment groups (14.3% among the patients assigned to total hip arthroplasty and 13.1% among those assigned to hemiarthroplasty, P = 0.48). Serious adverse events occurred in 300 patients (41.8%) assigned to total hip arthroplasty and in 265 patients (36.7%) assigned to hemiarthroplasty. CONCLUSIONS: Among independently ambulating patients with displaced femoral neck fractures, the incidence of secondary procedures did not differ significantly between patients who were randomly assigned to undergo total hip arthroplasty and those who were assigned to undergo hemiarthroplasty, and total hip arthroplasty provided a clinically unimportant improvement over hemiarthroplasty in function and quality of life over 24 months. (Funded by the Canadian Institutes of Health Research and others; ClinicalTrials.gov number, NCT00556842.)
    • 

    corecore