Transcranial Magnetic Resonance Imaging-Guided Focused Ultrasound Treatment at 1.5 T: A Retrospective Study on Treatment- and Patient-Related Parameters Obtained From 52 Procedures
Objective: To present a retrospective analysis of patient- and sonication-related parameters of a group of patients treated with a transcranial magnetic resonance imaging (MRI)-guided focused ultrasound (tcMRgFUS) system integrated with a 1.5-T MRI unit. Methods: The data obtained from 59 patients, who underwent the tcMRgFUS procedure from January 2015 to April 2019, were retrospectively reviewed for this study. The following data, among others, were mainly collected: skull density ratio (SDR), skull area (SA), number of available transducer elements (Tx), and estimated focal power at target (FP). For each of the four different treatment stages, we calculated the number of sonication processes (S-n), user-defined sonication power (S-p), effective measured power (S-mp), sonication duration (S-d), user-defined energy (E), effective measured energy (E-m), maximum temperature (T-max), and MR thermometry plane orientation. Furthermore, the time delay between each sonication (S-t) and the total treatment time (T-t) were recorded. Results: Fifty-two patients (40 males and 12 females; age 64.51 +/- SD 11.90 years; range 26-86 years), who underwent unilateral Vim thalamotomy (left = 50, 96.15%; right = 2, 3.85%) for medication-refractory essential tremor (n = 39; 78%) or Parkinson tremor (n = 13; 22%) were considered. A total of 1,068 (95.10%) sonication processes were included in our final analysis (average S-n per treatment: 20.65 +/- 6.18; range 13-41). The energy released onto the planned target was found to decrease with the SDR for all temperature ranges. A positive correlation was observed between the slope of T-max vs. E-m plot and the SDR (R-2 = 0.765; p < 0.001). In addition, the T-max was positively correlated with SDR (R-2 = 0.398; p < 0.005). On the contrary, no significant correlation was found between SDR and SA or Tx. An analysis of the MR thermometry scanning plane indicated that, at our site, the axial and the coronal planes were used (on average) 10.4 (SD +/- 3.8) and 7.7 (SD +/- 3.0) times, respectively, whereas the sagittal plane was used only 2.5 (SD +/- 3.0) times per treatment. Conclusion: Our results confirm the factors that significantly influence the course of a tcMRgFUS procedure even when a 1.5-T MRI scanner is used for procedure guidance. The experience we gained in this study indicates that the SDR remains one of the most significant technical parameters to be considered in a tcMRgFUS procedure. The possibility of prospectively setting the sonication energy according to the presented curves of energy delivery as a function of SDR for each treatment stage could provide a further understanding and a greater awareness of this emerging technology
Measurements of polarized photo-pion production on longitudinally polarized HD and Implications for Convergence of the GDH Integral
We report new measurements of inclusive pion production from frozen-spin HD
for polarized photon beams covering the Delta(1232) resonance. These provide
data simultaneously on both H and D with nearly complete angular distributions
of the spin-difference cross sections entering the Gerasimov-Drell-Hearn (GDH)
sum rule. Recent results from Mainz and Bonn exceed the GDH prediction for the
proton by 22 microbarns, suggesting as yet unmeasured high-energy components.
Our pi0 data reveal a different angular dependence than assumed in Mainz
analyses and integrate to a value that is 18 microbarns lower, suggesting a
more rapid convergence. Our results for deuterium are somewhat lower than
published data, considerably more precise and generally lower than available
calculations.Comment: 4 pages, 4 figures. Submitted for publication in Physical Review
Letter
Enhancing image contrast using coherent states and photon number resolving detectors
We experimentally map the transverse profile of diffraction-limited beams
using photon-number-resolving detectors. We observe strong compression of
diffracted beam profiles for high detected photon number. This effect leads to
higher contrast than a conventional irradiance profile between two Airy
disk-beams separated by the Rayleigh criterion.Comment: 7 pages, 3 figures, accepted for publication in Optics Expres
Analysis of cerebrospinal fluid from cattle with central nervous system disorders after storage for 24Â hours with autologous serum
BACKGROUND: We compared the changes in cell morphology, total and differential cell counts between cerebrospinal fluid (CSF) samples analyzed within an hour of collection (fresh sample) and after the addition of autologous serum and storage for 24Â h (stored sample) in 27 cattle with central nervous system disorders. RESULTS: There was a positive linear correlation between total and differential cell counts in the fresh and the stored samples. Cell morphology was preserved in all stored samples, except for increased vacuolization of mononuclear cells and cleaved nuclei of some small mononuclear cells. In the stored CSF samples, the total nucleated cell count and monocyte percentage were decreased (Pâ=â0.01; Pâ=â0.03), while the lymphocyte percentage was increased (Pâ=â0.04). Mononuclear pleocytosis diagnosed in 20 fresh samples was cytologically confirmed in 12 of the 20 stored samples. In the remaining eight stored samples, the number of total nucleated cells was within the normal range. Neutrophilic pleocytosis was confirmed in all seven stored samples. The overall agreement rate between cytologic interpretation of the fresh and the stored CSF samples was 70Â % (100Â % for neutrophilic pleocytosis and 60Â % for mononuclear pleocytosis). CONCLUSIONS: Adding 11Â % of autologous serum to CSF samples might allow delayed analysis with a good agreement rate for CSF cytological interpretation. Caution is nonetheless warranted, as animal age, anamnesis, and neurological presentation need to be considered when interpreting stored CSF without pleocytosis. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12917-015-0502-x) contains supplementary material, which is available to authorized users
Organic film thickness influence on the bias stress instability in Sexithiophene Field Effect Transistors
In this paper, the dynamics of bias stress phenomenon in Sexithiophene (T6)
Field Effect Transistors (FETs) has been investigated. T6 FETs have been
fabricated by vacuum depositing films with thickness from 10 nm to 130 nm on
Si/SiO2 substrates. After the T6 film structural analysis by X-Ray diffraction
and the FET electrical investigation focused on carrier mobility evaluation,
bias stress instability parameters have been estimated and discussed in the
context of existing models. By increasing the film thickness, a clear
correlation between the stress parameters and the structural properties of the
organic layer has been highlighted. Conversely, the mobility values result
almost thickness independent
Recent developments in planet migration theory
Planetary migration is the process by which a forming planet undergoes a
drift of its semi-major axis caused by the tidal interaction with its parent
protoplanetary disc. One of the key quantities to assess the migration of
embedded planets is the tidal torque between the disc and planet, which has two
components: the Lindblad torque and the corotation torque. We review the latest
results on both torque components for planets on circular orbits, with a
special emphasis on the various processes that give rise to additional, large
components of the corotation torque, and those contributing to the saturation
of this torque. These additional components of the corotation torque could help
address the shortcomings that have recently been exposed by models of planet
population syntheses. We also review recent results concerning the migration of
giant planets that carve gaps in the disc (type II migration) and the migration
of sub-giant planets that open partial gaps in massive discs (type III
migration).Comment: 52 pages, 18 figures. Review article to be published in "Tidal
effects in Astronomy and Astrophysics", Lecture Notes in Physic
Dispersion enhancement and damping by buoyancy driven flows in 2D networks of capillaries
The influence of a small relative density difference on the displacement of
two miscible liquids is studied experimentally in transparent 2D networks of
micro channels. Both stable displacements in which the denser fluid enters at
the bottom of the cell and displaces the lighter one and unstable displacements
in which the lighter fluid is injected at the bottom and displaces the denser
one are realized. Except at the lowest mean flow velocity U, the average
of the relative concentration satisfies a convection-dispersion
equation. The dispersion coefficient is studied as function of the relative
magnitude of fluid velocity and of the velocity of buoyancy driven fluid
motion. A model is suggested and its applicability to previous results obtained
in 3D media is discussed
Convective heat transfer in cellular ceramic: A 3D numerical solution
Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014.In this work, three-dimensional thermo fluid dynamics analyses were performed in order to evaluate the convective heat transfer coefficient for cellular ceramics, both random (i.e. foams) and regular (i.e. lattices). The study aimed at evaluating the heat exchange performance of cellular ceramics with the scope of engineering their morphology in order to maximize the ratio between heat exchange and pressure drop.
Performed simulations focus on capturing the relevance of cell morphology on thermal convection and pressure drop of cellular ceramics within a porosity range of 75â90% and at different fluid velocities. Computational analyses were performed with the commercial CFD package ANSYS-Fluent. Results show that parameters affecting most the pressure drop are porosity and cell aspect ratio; on the other hand, the thermal convective coefficient is strongly dependent on surface area, which, in turn, is directly related to cell morphology.dc201
Extended thromboprophylaxis with betrixaban in acutely ill medical patients
BACKGROUND:
Patients with acute medical illnesses are at prolonged risk for venous thrombosis. However, the appropriate duration of thromboprophylaxis remains unknown.
METHODS:
Patients who were hospitalized for acute medical illnesses were randomly assigned to receive subcutaneous enoxaparin (at a dose of 40 mg once daily) for 10±4 days plus oral betrixaban placebo for 35 to 42 days or subcutaneous enoxaparin placebo for 10±4 days plus oral betrixaban (at a dose of 80 mg once daily) for 35 to 42 days. We performed sequential analyses in three prespecified, progressively inclusive cohorts: patients with an elevated d-dimer level (cohort 1), patients with an elevated d-dimer level or an age of at least 75 years (cohort 2), and all the enrolled patients (overall population cohort). The statistical analysis plan specified that if the between-group difference in any analysis in this sequence was not significant, the other analyses would be considered exploratory. The primary efficacy outcome was a composite of asymptomatic proximal deep-vein thrombosis and symptomatic venous thromboembolism. The principal safety outcome was major bleeding.
RESULTS:
A total of 7513 patients underwent randomization. In cohort 1, the primary efficacy outcome occurred in 6.9% of patients receiving betrixaban and 8.5% receiving enoxaparin (relative risk in the betrixaban group, 0.81; 95% confidence interval [CI], 0.65 to 1.00; P=0.054). The rates were 5.6% and 7.1%, respectively (relative risk, 0.80; 95% CI, 0.66 to 0.98; P=0.03) in cohort 2 and 5.3% and 7.0% (relative risk, 0.76; 95% CI, 0.63 to 0.92; P=0.006) in the overall population. (The last two analyses were considered to be exploratory owing to the result in cohort 1.) In the overall population, major bleeding occurred in 0.7% of the betrixaban group and 0.6% of the enoxaparin group (relative risk, 1.19; 95% CI, 0.67 to 2.12; P=0.55).
CONCLUSIONS:
Among acutely ill medical patients with an elevated d-dimer level, there was no significant difference between extended-duration betrixaban and a standard regimen of enoxaparin in the prespecified primary efficacy outcome. However, prespecified exploratory analyses provided evidence suggesting a benefit for betrixaban in the two larger cohorts. (Funded by Portola Pharmaceuticals; APEX ClinicalTrials.gov number, NCT01583218.)
Limits on light-speed anisotropies from Compton scattering of high-energy electrons
The possibility of anisotropies in the speed of light relative to the
limiting speed of electrons is considered. The absence of sidereal variations
in the energy of Compton-edge photons at the ESRF's GRAAL facility constrains
such anisotropies representing the first non-threshold collision-kinematics
study of Lorentz violation. When interpreted within the minimal Standard-Model
Extension, this result yields the two-sided limit of 1.6 x 10^{-14} at 95%
confidence level on a combination of the parity-violating photon and electron
coefficients kappa_{o+} and c. This new constraint provides an improvement over
previous bounds by one order of magnitude.Comment: 4 pages, 4 figure
- âŠ