61 research outputs found

    A novel, comprehensive tool for predicting 30-day mortality after surgical aortic valve replacement

    Get PDF
    OBJECTIVES: We sought to develop and validate a novel risk assessment tool for the prediction of 30-day mortality after surgical aortic valve replacement incorporating a patient's frailty. METHODS: Overall, 4718 patients from the multicentre study OBSERVANT was divided into derivation (n=3539) and validation (n=1179) cohorts. A stepwise logistic regression procedure and a criterion based on Akaike information criteria index were used to select variables associated with 30-day mortality. The performance of the regression model was compared with that of European System for Cardiac Operative Risk Evaluation (EuroSCORE) II. RESULTS: At 30 days, 90 (2.54%) and 35 (2.97%) patients died in the development and validation data sets, respectively. Age, chronic obstructive pulmonary disease, concomitant coronary revascularization, frailty stratified according to the Geriatric Status Scale, urgent procedure and estimated glomerular filtration rate were independent predictors of 30-day mortality. The estimated OBS AVR score showed higher discrimination (area under curve 0.76 vs 0.70, P CONCLUSIONS: The OBS AVR risk score showed high discrimination and calibration abilities in predicting 30-day mortality after surgical aortic valve replacement. The addition of a simplified frailty assessment into the model seems to contribute to an improved predictive ability over the EuroSCORE II. The OBS AVR risk score showed a significant association with long-term mortality.Peer reviewe

    Mid-term outcomes of Sapien 3 versus Perimount Magna Ease for treatment of severe aortic stenosis

    Get PDF
    BackgroundThere is limited information on the longer-term outcome after transcatheter aortic valve replacement (TAVR) with new-generation prostheses compared to surgical aortic valve replacement (SAVR). The aim of this study was to compare the mid-term outcomes after TAVR with Sapien 3 and SAVR with Perimount Magna Ease bioprostheses for severe aortic stenosis.MethodsIn a retrospective study, we included patients who underwent transfemoral TAVR with Sapien 3 or SAVR with Perimount Magna Ease bioprosthesis between January 2008 and October 2017 from the nationwide FinnValve registry. Propensity score matching was performed to adjust for differences in the baseline characteristics. The Kaplan-Meir method was used to estimate late mortality.ResultsA total of 2000 patients were included (689 in the TAVR cohort and 1311 in the SAVR cohort). Propensity score matching resulted in 308 pairs (STS score, TAVR 3.52.2% vs. SAVR 3.52.8%, p=0.918). In-hospital mortality was 3.6% after SAVR and 1.3% after TAVR (p=0.092). Stroke, acute kidney injury, bleeding and atrial fibrillation were significantly more frequent after SAVR, but higher rate of vascular complications was observed after TAVR. The cumulative incidence of permanent pacemaker implantation at 4years was 13.9% in the TAVR group and 6.9% in the SAVR group (p=0.0004). At 4-years, all-cause mortality was 20.6% for SAVR and 25.9% for TAVR (p=0.910). Four-year rates of coronary revascularization, prosthetic valve endocarditis and repeat aortic valve intervention were similar between matched cohorts.Conclusions p id=Par The Sapien 3 bioprosthesis achieves comparable midterm outcomes to a surgical bioprosthesis with proven durability such as the Perimount Magna Ease. However, the Sapien 3 bioprosthesis was associated with better early outcome.Trial registration p id=Par ClinicalTrials.gov Identifier: NCT03385915.Peer reviewe

    Intensive Care Unit Admission Parameters Improve the Accuracy of Operative Mortality Predictive Models in Cardiac Surgery

    Get PDF
    BACKGROUND: Operative mortality risk in cardiac surgery is usually assessed using preoperative risk models. However, intraoperative factors may change the risk profile of the patients, and parameters at the admission in the intensive care unit may be relevant in determining the operative mortality. This study investigates the association between a number of parameters at the admission in the intensive care unit and the operative mortality, and verifies the hypothesis that including these parameters into the preoperative risk models may increase the accuracy of prediction of the operative mortality. METHODOLOGY: 929 adult patients who underwent cardiac surgery were admitted to the study. The preoperative risk profile was assessed using the logistic EuroSCORE and the ACEF score. A number of parameters recorded at the admission in the intensive care unit were explored for univariate and multivariable association with the operative mortality. PRINCIPAL FINDINGS: A heart rate higher than 120 beats per minute and a blood lactate value higher than 4 mmol/L at the admission in the intensive care unit were independent predictors of operative mortality, with odds ratio of 6.7 and 13.4 respectively. Including these parameters into the logistic EuroSCORE and the ACEF score increased their accuracy (area under the curve 0.85 to 0.88 for the logistic EuroSCORE and 0.81 to 0.86 for the ACEF score). CONCLUSIONS: A double-stage assessment of operative mortality risk provides a higher accuracy of the prediction. Elevated blood lactates and tachycardia reflect a condition of inadequate cardiac output. Their inclusion in the assessment of the severity of the clinical conditions after cardiac surgery may offer a useful tool to introduce more sophisticated hemodynamic monitoring techniques. Comparison between the predicted operative mortality risk before and after the operation may offer an assessment of the operative performance

    Impact of an Early Invasive Strategy versus Conservative Strategy for Unstable Angina and Non-ST Elevation Acute Coronary Syndrome in Patients with Chronic Kidney Disease: A Systematic Review.

    Get PDF
    BACKGROUND: Clinical practice guidelines support an early invasive approach after NSTE-ACS in patients with chronic kidney disease (CKD). There is no direct randomised controlled trial evidence in the CKD population, and whether the benefit of an early invasive approach is maintained across the spectrum of severity of CKD remains controversial. METHODS: We conducted a systematic review to evaluate the association between an early invasive approach and all-cause mortality in patients with CKD. We searched MEDLINE and EMBASE (1990-May 2015) and article reference lists. Data describing study design, participants, invasive management strategies, renal function, all-cause mortality and risk of bias were extracted. RESULTS: 3,861 potentially relevant studies were identified. Ten studies, representing data on 147,908 individuals with NSTE-ACS met the inclusion criteria. Qualitative heterogeneity in the definitions of early invasive approach, comparison groups and renal dysfunction existed. Meta-analysis of the RCT derived and observational data were generally supportive of an early invasive approach in CKD (RR0.76 (95% CI 0.49-1.17) and RR0.50 (95%CI 0.42-0.59) respectively). Meta-analysis of the observational studies demonstrated a large degree of heterogeneity (I2 79%) driven in part by study size and heterogeneity across various kidney function levels. CONCLUSIONS: The observational data support that an early invasive approach after NSTE-ACS confers a survival benefit in those with early-moderate CKD. Local opportunities for quality improvement should be sought. Those with severe CKD and the dialysis population are high risk and under-studied. Novel and inclusive approaches for CKD and dialysis patients in cardiovascular clinical trials are needed

    Mid-term outcomes of Sapien 3 versus Perimount Magna Ease for treatment of severe aortic stenosis

    Get PDF
    Background: There is limited information on the longer-term outcome after transcatheter aortic valve replacement (TAVR) with new-generation prostheses compared to surgical aortic valve replacement (SAVR). The aim of this study was to compare the mid-term outcomes after TAVR with Sapien 3 and SAVR with Perimount Magna Ease bioprostheses for severe aortic stenosis.Methods: In a retrospective study, we included patients who underwent transfemoral TAVR with Sapien 3 or SAVR with Perimount Magna Ease bioprosthesis between January 2008 and October 2017 from the nationwide FinnValve registry. Propensity score matching was performed to adjust for differences in the baseline characteristics. The Kaplan-Meir method was used to estimate late mortality.Results: A total of 2000 patients were included (689 in the TAVR cohort and 1311 in the SAVR cohort). Propensity score matching resulted in 308 pairs (STS score, TAVR 3.52.2% vs. SAVR 3.52.8%, p=0.918). In-hospital mortality was 3.6% after SAVR and 1.3% after TAVR (p=0.092). Stroke, acute kidney injury, bleeding and atrial fibrillation were significantly more frequent after SAVR, but higher rate of vascular complications was observed after TAVR. The cumulative incidence of permanent pacemaker implantation at 4years was 13.9% in the TAVR group and 6.9% in the SAVR group (p=0.0004). At 4-years, all-cause mortality was 20.6% for SAVR and 25.9% for TAVR (p=0.910). Four-year rates of coronary revascularization, prosthetic valve endocarditis and repeat aortic valve intervention were similar between matched cohorts.Conclusions: The Sapien 3 bioprosthesis achieves comparable midterm outcomes to a surgical bioprosthesis with proven durability such as the Perimount Magna Ease. However, the Sapien 3 bioprosthesis was associated with better early outcome.Trial registration: ClinicalTrials.gov Identifier: NCT03385915.</div

    Comparison of Outcomes After Transcatheter Aortic Valve Replacement vs Surgical Aortic Valve Replacement Among Patients With Aortic Stenosis at Low Operative Risk

    Get PDF
    Importance:  Transcatheter aortic valve replacement (TAVR) has been shown to be a valid alternative to surgical aortic valve replacement (SAVR) in patients at high operative risk with severe aortic stenosis (AS). However, the evidence of the benefits and harms of TAVR in patients at low operative risk is still scarce.Objective:  To compare the short-term and midterm outcomes after TAVR and SAVR in low-risk patients with AS.Design, Setting, and Participants:  This retrospective comparative effectiveness cohort study used data from the Nationwide Finnish Registry of Transcatheter and Surgical Aortic Valve Replacement for Aortic Valve Stenosis of patients at low operative risk who underwent TAVR or SAVR with a bioprosthesis for severe AS from January 1, 2008, to November 30, 2017. Low operative risk was defined as a Society of Thoracic Surgeons Predicted Risk of Mortality score less than 3% without other comorbidities of clinical relevance. One-to-one propensity score matching was performed to adjust for baseline covariates between the TAVR and SAVR cohorts.Exposures:  Primary TAVR or SAVR with a bioprosthesis for AS with or without associated coronary revascularization.Main Outcomes and Measures:  The primary outcomes were 30-day and 3-year survival.Results:  Overall, 2841 patients (mean [SD] age, 74.0 [6.2] years; 1560 [54.9%] men) fulfilled the inclusion criteria and were included in the analysis; TAVR was performed in 325 patients and SAVR in 2516 patients. Propensity score matching produced 304 pairs with similar baseline characteristics. Third-generation devices were used in 263 patients (86.5%) who underwent TAVR. Among these matched pairs, 30-day mortality was 1.3% after TAVR and 3.6% after SAVR (P = .12). Three-year survival was similar in the study cohorts (TAVR, 85.7%; SAVR, 87.7%; P = .45). Interaction tests found no differences in terms of 3-year survival between the study cohorts in patients younger than vs older than 80 years or in patients who received recent aortic valve prostheses vs those who did not.Conclusions and Relevance:  Transcatheter aortic valve replacement using mostly third-generation devices achieved similar short- and mid-term survival compared with SAVR in low-risk patients. Further studies are needed to assess the long-term durability of TAVR prostheses before extending their use to low-risk patients.</p

    Hospital-level associations with 30-day patient mortality after cardiac surgery: a tutorial on the application and interpretation of marginal and multilevel logistic regression

    Get PDF
    Background: Marginal and multilevel logistic regression methods can estimate associations between hospital-level factors and patient-level 30-day mortality outcomes after cardiac surgery. However, it is not widely understood how the interpretation of hospital-level effects differs between these methods. Methods. The Australasian Society of Cardiac and Thoracic Surgeons (ASCTS) registry provided data on 32,354 patients undergoing cardiac surgery in 18 hospitals from 2001 to 2009. The logistic regression methods related 30-day mortality after surgery to hospital characteristics with concurrent adjustment for patient characteristics. Results: Hospital-level mortality rates varied from 1.0% to 4.1% of patients. Ordinary, marginal and multilevel regression methods differed with regard to point estimates and conclusions on statistical significance for hospital-level risk factors; ordinary logistic regression giving inappropriately narrow confidence intervals. The median odds ratio, MOR, from the multilevel model was 1.2 whereas ORs for most patient-level characteristics were of greater magnitude suggesting that unexplained between-hospital variation was not as relevant as patient-level characteristics for understanding mortality rates. For hospital-level characteristics in the multilevel model, 80% interval ORs, IOR-80%, supplemented the usual ORs from the logistic regression. The IOR-80% was (0.8 to 1.8) for academic affiliation and (0.6 to 1.3) for the median annual number of cardiac surgery procedures. The width of these intervals reflected the unexplained variation between hospitals in mortality rates; the inclusion of one in each interval suggested an inability to add meaningfully to explaining variation in mortality rates. Conclusions: Marginal and multilevel models take different approaches to account for correlation between patients within hospitals and they lead to different interpretations for hospital-level odds ratios. © 2012 Sanagou et al; licensee BioMed Central Ltd

    Comparison of Outcomes After Transcatheter Aortic Valve Replacement vs Surgical Aortic Valve Replacement Among Patients With Aortic Stenosis at Low Operative Risk

    Get PDF
    IMPORTANCE Transcatheter aortic valve replacement (TAVR) has been shown to be a valid alternative to surgical aortic valve replacement (SAVR) in patients at high operative risk with severe aortic stenosis (AS). However, the evidence of the benefits and harms of TAVR in patients at low operative risk is still scarce. OBJECTIVE To compare the short-term and midterm outcomes after TAVR and SAVR in low-risk patients with AS. DESIGN, SETTING, AND PARTICIPANTS This retrospective comparative effectiveness cohort study used data from the Nationwide Finnish Registry of Transcatheter and Surgical Aortic Valve Replacement for Aortic Valve Stenosis of patients at low operative risk who underwent TAVR or SAVR with a bioprosthesis for severe AS from January 1, 2008, to November 30, 2017. Low operative risk was defined as a Society of Thoracic Surgeons Predicted Risk of Mortality score less than 3% without other comorbidities of clinical relevance. One-to-one propensity score matching was performed to adjust for baseline covariates between the TAVR and SAVR cohorts. EXPOSURES Primary TAVR or SAVR with a bioprosthesis for AS with or without associated coronary revascularization. MAIN OUTCOMES AND MEASURES The primary outcomes were 30-day and 3-year survival. RESULTS Overall, 2841 patients (mean [SD] age, 74.0 [6.2] years; 1560 [54.9%] men) fulfilled the inclusion criteria and were included in the analysis; TAVR was performed in 325 patients and SAVR in 2516 patients. Propensity score matching produced 304 pairs with similar baseline characteristics. Third-generation devices were used in 263 patients (86.5%) who underwent TAVR. Among these matched pairs, 30-day mortality was 1.3% after TAVR and 3.6% after SAVR (P=.12). Three-year survival was similar in the study cohorts (TAVR, 85.7%; SAVR, 87.7%; P=.45). Interaction tests found no differences in terms of 3-year survival between the study cohorts in patients younger than vs older than 80 years or in patients who received recent aortic valve prostheses vs those who did not. CONCLUSIONS AND RELEVANCE Transcatheter aortic valve replacement using mostly third-generation devices achieved similar short- and mid-term survival compared with SAVR in low-risk patients. Further studies are needed to assess the long-term durability of TAVR prostheses before extending their use to low-risk patients.Peer reviewe
    • …
    corecore