16 research outputs found

    Low Voltage Control for the Liquid Argon Hadronic End-Cap Calorimeter of ATLAS

    Get PDF
    At the ATLAS detector a SCADA system surveys and controls the sub- detectors. The link is realized by PVSS2 software and a CanBus hardware system. The low voltages for the Hadronic Endcaps of the liquid argon calorimeter are produced by DC/DC-converters in the power boxes and split into 320 channels corresponding to the pre- amplifier and summing boards in the cryostat. Six units of a prototype distribution board are currently under test. Each of it contains 2 ELMBs as CanBus interface, a FPGA of type QL3012 for digital control and 30 low voltage regulators for the individual fine adjustments of the outputs

    Design and implementation of the Front End Board for the readout of the ATLAS liquid argon calorimeters

    Get PDF
    The ATLAS detector has been designed for operation at CERN's Large Hadron Collider. ATLAS includes a complex system of liquid argon calorimeters. The electronics for amplifying, shaping, sampling, pipelining, and digitizing the calorimeter signals is implemented on the Front End Boards (FEBs). This paper describes the design, implementation and production of the FEBs and presents measurement results from testing performed at several stages during the production process

    ATLAS liquid argon calorimeter front end electronics

    Get PDF
    The ATLAS detector has been designed for operation at CERN's Large Hadron Collider. ATLAS includes a complex system of liquid argon calorimeters. This paper describes the architecture and implementation of the system of custom front end electronics developed for the readout of the ATLAS liquid argon calorimeters

    Construction, assembly and testing of the ATLAS hadronic end-cap calorimeter

    Get PDF
    The construction and assembly of the four wheels of the ATLAS hadronic end-cap calorimeter and their insertion into the two end-cap cryostats are described. The results of the qualification tests prior to installation of the two cryostats in the ATLAS experimental cavern are reviewed

    Performance of the ATLAS Hadronic End-Cap Calorimeter in Beam Tests

    No full text
    Modules of the ATLAS liquid argon Hadronic End-cap calorimeter (HEC) were exposed to beams of electrons, muons and pions in the energy range 6GeV<E<200GeV at the CERN SPS. A description of the HEC and of the beam test setup are given. Results on the energy response and resolution are presented and compared with simulations. The ATLAS energy resolution for jets in the end-cap region is inferred and meets the ATLAS requirements