294 research outputs found

    Fear of covid-19 for individuals and family members: Indications from the national cross-sectional study of the epicovid19 web-based survey

    Get PDF
    The study analyzed the association of the fear of contagion for oneself and for family members (FMs) during the first wave of the COVID-19 pandemic, with demographic and socioeconomic status (SES) and health factors. The study was performed within the EPICOVID19 web-based Italian survey, involving adults from April–June 2020. Out of 207,341 respondents, 95.9% completed the questionnaire (60% women with an average age of 47.3 vs. 48.9 years among men). The association between fear and demographic and SES characteristics, contacts with COVID-19 cases, nasopharyngeal swab, self-perceived health, flu vaccination, chronic diseases and specific symptoms was analyzed by logistic regression model; odds ratios adjusted for sex, age, education and occupation were calculated (aORs). Fear for FMs prevailed over fear for oneself and was higher among women than men. Fear for oneself decreased with higher levels of education and in those who perceived good health. Among those vaccinated for the flu, 40.8% responded they had feelings of fear for themselves vs. 34.2% of the not vaccinated. Fear increased when diseases were declared and it was higher when associated with symptoms such as chest pain, olfactory/taste disorders, heart palpitations (aORs > 1.5), lung or kidney diseases, hypertension, depression and/or anxiety. Trends in fear by region showed the highest percentage of positive responses in the southern regions. The knowledge gained from these results should be used to produce tailored messages and shared public health decisions

    Direction distributions of neutrons and reference values of the personal dose equivalent in workplace fields

    Get PDF
    Within the EC project EVIDOS, double-differential (energy and direction) fluence spectra were determined by means of novel direction spectrometers. By folding the spectra with fluence-to-dose equivalent conversion coefficients, contributions to H*(10) for 14 directions, and values of the personal dose equivalent Hp(10) and the effective dose E for 6 directions of a person's orientation in the field were determined. The results of the measurements and calculations obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucléaire) and at Ringhals (pressurised reactor and transport cask) are presente

    Characterisation of mixed neutron-photon workplace fields at nuclear facilities by spectrometry (energy and direction) within the EVIDOS project

    Get PDF
    Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discusse

    Cutaneous cryptococcosis in a patient affected by chronic lymphocytic leukaemia: a case report.

    Get PDF
    Cryptococcosis is an opportunistic infection, the incidence of which is increased in the immunocompromised patients. Cryptococcus neoformans is an encapsulated fungus that mainly infects the lungs and the central nervous system, possibly involving different organs. Cutaneous cryptococcosis is classified into localized infection, usually occurring after traumatic inoculation (primary cutaneous cryptococcosis) and cutaneous manifestation due to hematogenous dissemination (secondary cutaneous cryptococcosis), mostly in patients with underlying immunosuppression. We report a case of cutaneous cryptococcosis in a patient affected by chronic lymphocytic leukaemia

    Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part II: conclusions and recommendations

    Get PDF
    The paper presents the main conclusions and recommendations derived from the EVIDOS project, which is supported by the European Commission within the 5th Framework Programme. EVIDOS aims at evaluating state of the art neutron dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This analysis complements a series of individual papers which present detailed results and it summarises the main findings from a practical point of view. Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter result

    Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project

    Get PDF
    The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those field

    Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part I: scope and methods of the project

    Get PDF
    Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europ
    • …
    corecore