64 research outputs found

    The small angle rear tracking detector of ZEUS

    Get PDF
    Abstract The design, construction, installation, and performance of the small angle rear tracking detector of the ZEUS experiment are described. The results on electron position measurement, electron energy correction, and background reduction at the first-level trigger are presented. The impact on the measurement of the proton structure function is discussed

    The PHENIX Experiment at RHIC

    Full text link
    The physics emphases of the PHENIX collaboration and the design and current status of the PHENIX detector are discussed. The plan of the collaboration for making the most effective use of the available luminosity in the first years of RHIC operation is also presented.Comment: 5 pages, 1 figure. Further details of the PHENIX physics program available at http://www.rhic.bnl.gov/phenix

    Performance of the ATLAS Electromagnetic Calorimeter End-cap Module 0

    Get PDF
    The construction and beam test results of the ATLAS electromagnetic end-cap calorimeter pre-production module 0 are presented. The stochastic term of the energy resolution is between 10% GeV^1/2 and 12.5% GeV^1/2 over the full pseudorapidity range. Position and angular resolutions are found to be in agreement with simulation. A global constant term of 0.6% is obtained in the pseudorapidity range 2.5 < eta < 3.2 (inner wheel)

    Performance of the ATLAS electromagnetic calorimeter end-cap module 0

    Get PDF
    The construction and beam test results of the ATLAS electromagnetic end-cap calorimeter pre-production module 0 are presented. The stochastic term of the energy resolution is between 10% GeV^1/2 and 12.5% GeV^1/2 over the full pseudorapidity range. Position and angular resolutions are found to be in agreement with simulation. A global constant term of 0.6% is obtained in the pseudorapidity range 2.5 eta 3.2 (inner wheel)

    ATLAS detector and physics performance: Technical Design Report, 1

    Get PDF

    Development of the front end electronics for the ZEUS high resolution calorimeter

    No full text
    The development and design of the pipeline data aquisition system for the high resolution ZEUS calorimeter is described. Details of the front and analog card and the performance are given. A description of the custom pipeline and buffer multiplexer chips is given, analog with test results for the pipeline chip. In addition, some results are presented for a CCD test system built to evaluate the pipeline principles using the ZEUS calorimeter prototype at the CERN PS

    Warning Effectiveness: What Do We Need to Know

    No full text
    The forensic area of practice for human factors engineers has brought into sharp focus the differences of opinion which exist regarding the effectiveness of warnings in bringing about safe behavior on the part of the user of a product. This paper addresses the major issues which the authors believe must be researched further to provide the definitive answers needed regarding the effectiveness of warnings in a variety of possible applications. A review of the literature will demonstrate that there are few studies of warning effectiveness per se, while there are many studies that address such issues as the need for warnings and presumed criteria for preparing effective warnings. It is suggested that further research is needed which addresses warning effectiveness in actual use situations, and in turn identifies the importance of such variables as stimulus energy level, information overload, risk perception, cost of compliance and the interaction of warnings, instructions and training.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline
    corecore