243 research outputs found
The pinna enhances angular discrimination in the 1 frontal hemifield
Human sound localization in the horizontal dimension is thought to be dominated by binaural cues, particularly interaural time delays, because monaural localization in this dimension is relatively poor. Remaining ambiguities of front versus back and up versus down are distinguished by high-frequency spectral cues generated by the pinna. The experiments in this study show that this account is incomplete. Using binaural listening throughout, the pinna substantially enhanced horizontal discrimination in the frontal hemifield, making discrimination in front better than discrimination at the rear, particularly for directions away from the median plane. Eliminating acoustic effects of the pinna by acoustically bypassing them or low-pass filtering abolished the advantage at the front without affecting the rear. Acoustic measurements revealed a pinna-induced spectral prominence that shifts smoothly in frequency as sounds move from 0° to 90° azimuth. The improved performance is discussed in terms of the monaural and binaural changes induced by the pinna
Practical utility of a head-mounted gaze-directed beamforming system
Assistive auditory devices that enhance signal-to-noise ratio must follow the user's changing attention; errors could lead to the desired source being suppressed as noise. A method for measuring the practical benefit of attention-following speech enhancement is described and used to show a benefit for gaze-directed beamforming over natural binaural hearing. First, participants watched a recorded video conference call between two people with six additional interfering voices in different directions. The directions of the target voices corresponded to the spatial layout of their video streams. A simulated beamformer was yoked to the participant's gaze direction using an eye tracker. For the control condition, all eight voices were spatially distributed in a simulation of unaided binaural hearing. Participants completed questionnaires on the content of the conversation, scoring twice as high in the questionnaires for the beamforming condition. Sentence-by-sentence intelligibility was then measured using new participants who viewed the same audiovisual stimulus for each isolated sentence. Participants recognized twice as many words in the beamforming condition. The results demonstrate the potential practical benefit of gaze-directed beamforming for hearing aids and illustrate how detailed intelligibility data can be retrieved from an experiment that involves behavioral engagement in an ongoing listening task
Evaluation of a method for enhancing interaural level differences at low frequencies.
A method (called binaural enhancement) for enhancing interaural level differences at low frequencies, based on estimates of interaural time differences, was developed and evaluated. Five conditions were compared, all using simulated hearing-aid processing: (1) Linear amplification with frequency-response shaping; (2) binaural enhancement combined with linear amplification and frequency-response shaping; (3) slow-acting four-channel amplitude compression with independent compression at the two ears (AGC4CH); (4) binaural enhancement combined with four-channel compression (BE-AGC4CH); and (5) four-channel compression but with the compression gains synchronized across ears. Ten hearing-impaired listeners were tested, and gains and compression ratios for each listener were set to match targets prescribed by the CAM2 fitting method. Stimuli were presented via headphones, using virtualization methods to simulate listening in a moderately reverberant room. The intelligibility of speech at ±60° azimuth in the presence of competing speech on the opposite side of the head at ±60° azimuth was not affected by the binaural enhancement processing. Sound localization was significantly better for condition BE-AGC4CH than for condition AGC4CH for a sentence, but not for broadband noise, lowpass noise, or lowpass amplitude-modulated noise. The results suggest that the binaural enhancement processing can improve localization for sounds with distinct envelope fluctuations
First Observation and Measurement of the Decay K+- -> pi+- e+ e- gamma
Using the full data set of the NA48/2 experiment, the decay K+- -> pi+- e+ e-
gamma is observed for the first time, selecting 120 candidates with 7.3 +- 1.7
estimated background events. With K+- -> pi+- pi0D as normalisation channel,
the branching ratio is determined in a model-independent way to be Br(K+- ->
pi+- e+ e- gamma, m_eegamma > 260 MeV/c^2) = (1.19 +- 0.12_stat +- 0.04_syst) x
10^-8. This measured value and the spectrum of the e+ e- gamma invariant mass
allow a comparison with predictions of Chiral Perturbation Theory.Comment: 13 pages, 3 figures. Accepted for publication in Phys.Lett.
Empirical parameterization of the K+- -> pi+- pi0 pi0 decay Dalitz plot
As first observed by the NA48/2 experiment at the CERN SPS, the \p0p0
invariant mass (M00) distribution from \kcnn decay shows a cusp-like anomaly
at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi
scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively,
has been recently reported. In the present work the Dalitz plot of this decay
is fitted to a new empirical parameterization suitable for practical purposes,
such as Monte Carlo simulations of K+- -> pi+- pi0 pi0 decays.Comment: 9 pages, 3 figures
Search for direct CP-violation in K+- --> pi+-pi0pi0 decays
A search for direct CP-violation in K+- --> pi+-pi0pi0 decays based on 47.14
million events has been performed by the NA48/2 experiment at the CERN SPS. The
asymmetry in the Dalitz plot linear slopes A_g=(g^+ - g^-)/(g^+ + g^-) is
measured to be A_g=(1.8 +- 2.6).10^{-4}. The design of the experiment and the
method of analysis provide good control of instrumental charge asymmetries in
this measurement. The precision of the result is limited by statistics and is
almost one order of magnitude better than that of previous measurements by
other experiments.Comment: 14 page
Recommended from our members
Search for sterile neutrino mixing in the MINOS long-baseline experiment
A search for depletion of the combined flux of active neutrino species over a 735 km baseline is reported using neutral-current interaction data recorded by the MINOS detectors in the NuMI neutrino beam. Such a depletion is not expected according to conventional interpretations of neutrino oscillation data involving the three known neutrino flavors. A depletion would be a signature of oscillations or decay to postulated noninteracting sterile neutrinos, scenarios not ruled out by existing data. From an exposure of 3.18×10^(20) protons on target in which neutrinos of energies between ∼500 MeV and 120 GeV are produced predominantly as ν_μ, the visible energy spectrum of candidate neutral-current reactions in the MINOS far detector is reconstructed. Comparison of this spectrum to that inferred from a similarly selected near-detector sample shows that of the portion of the ν_μ flux observed to disappear in charged-current interaction data, the fraction that could be converting to a sterile state is less than 52% at 90% confidence level (C.L.). The hypothesis that active neutrinos mix with a single sterile neutrino via oscillations is tested by fitting the data to various models. In the particular four-neutrino models considered, the mixing angles θ_(24) and θ_(34) are constrained to be less than 11° and 56° at 90% C.L., respectively. The possibility that active neutrinos may decay to sterile neutrinos is also investigated. Pure neutrino decay without oscillations is ruled out at 5.4 standard deviations. For the scenario in which active neutrinos decay into sterile states concurrently with neutrino oscillations, a lower limit is established for the neutrino decay lifetime τ_3/m_3>2.1×10^(-12) s/eV at 90% C.L
Neutrino and Antineutrino Inclusive Charged-current Cross Section Measurements with the MINOS Near Detector
The energy dependence of the neutrino-iron and antineutrino-iron inclusive
charged-current cross sections and their ratio have been measured using a
high-statistics sample with the MINOS Near Detector exposed to the NuMI beam
from the Main Injector at Fermilab. Neutrino and antineutrino fluxes were
determined using a low hadronic energy subsample of charged-current events. We
report measurements of neutrino-Fe (antineutrinoFe) cross section in the energy
range 3-50 GeV (5-50 GeV) with precision of 2-8% (3-9%) and their ratio which
is measured with precision 2-8%. The data set spans the region from low energy,
where accurate measurements are sparse, up to the high-energy scaling region
where the cross section is well understood.Comment: accepted by PR
A Study of Muon Neutrino Disappearance Using the Fermilab Main Injector Neutrino Beam
We report the results of a search for muon-neutrino disappearance by the Main
Injector Neutrino Oscillation Search. The experiment uses two detectors
separated by 734 km to observe a beam of neutrinos created by the Neutrinos at
the Main Injector facility at Fermi National Accelerator Laboratory. The data
were collected in the first 282 days of beam operations and correspond to an
exposure of 1.27e20 protons on target. Based on measurements in the Near
Detector, in the absence of neutrino oscillations we expected 336 +/- 14
muon-neutrino charged-current interactions at the Far Detector but observed
215. This deficit of events corresponds to a significance of 5.2 standard
deviations. The deficit is energy dependent and is consistent with two-flavor
neutrino oscillations according to delta m-squared = 2.74e-3 +0.44/-0.26e-3
eV^2 and sin^2(2 theta) > 0.87 at 68% confidence level.Comment: In submission to Phys. Rev.
- …