111 research outputs found
Glassy steel optimized for glass-forming ability and toughness
An alloy development strategy coupled with toughness assessments and ultrasonic measurements is implemented to design a series of iron-based glass-forming alloys that demonstrate improved glass-forming ability and toughness. The combination of good glass-forming ability and high toughness demonstrated by the present alloys is uncommon in Fe-based systems, and is attributed to the ability of these compositions to form stable glass configurations associated with low activation barriers for shear flow, which tend to promote plastic flow and give rise to a toughness higher than other known Fe-based bulk-glass-forming systems
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.Comment: 7 pages, 4 figure
Environmental monitoring : phase 5 final report (April 2019 - March 2020)
This report presents the results and interpretation for Phase 5 of an integrated environmental
monitoring programme that is being undertaken around two proposed shale gas sites in England –
Preston New Road, Lancashire and Kirby Misperton, North Yorkshire. The report should be read
in conjunction with previous reports freely available through the project website1
. These provide
additional background to the project, presentation of earlier results and the rationale for
establishment of the different elements of the monitoring programme
Recommended from our members
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Dark matter effective field theory scattering in direct detection experiments
We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.National Science Foundation (U.S.)United States. Dept. of EnergyNatural Sciences and Engineering Research Council of CanadaSpain. Ministerio de Economia y Competitividad (MultiDark
Improved WIMP-search reach of the CDMS II germanium data
CDMS II data from the five-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector weakly interacting massive particle (WIMP)-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to ~5  keV, to increase sensitivity near a WIMP mass of 8  GeV/c[superscript 2]. After unblinding, there were zero candidate events above a deposited energy of 10 keV and six events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of 1.8 × 10[superscript −44] and 1.18 × 10[superscript −41] at 90% confidence for 60 and 8.6  GeV/c[superscript 2] WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6)  GeV/c[superscript 2] WIMPs.National Science Foundation (U.S.)United States. Dept. of EnergyNatural Sciences and Engineering Research Council of CanadaSpain. Ministerio de Economia y Competitividad (MultiDark
Demonstration of surface electron rejection with interleaved germanium detectors for dark matter searches
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two 210 Pb sources producing ∼130 beta decays/hr. In ∼800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 × 10−5 at 90% C.L., corresponding to < 0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment
- …