1,139 research outputs found

    A novel electroanalytical approach to the measurement of B vitamins in food supplements based on screen-printed carbon sensors

    Get PDF
    © 2017 Elsevier B.V. This paper describes the development of a novel electrochemical assay for the measurement of water-soluble vitamins in food and pharmaceutical products. The optimum conditions for the determination of vitamin B1 (thiamine), B2 (riboflavin) and B6 (pyridoxine) in phosphate buffer were established using cyclic voltammetry in conjunction with screen printed carbon electrodes (SPCEs). The optimum current response for all three vitamins was achieved in 0.1 M phosphate buffer pH 11 using an initial potential of −1.0 V. Using square wave voltammetry, the linear ranges for thiamine, riboflavin, and pyridoxine were found to be: 15–110 µg/ml, 0.1–20 µg/ml, and 2–80 µg/ml respectively. The application of the method to a commercial food product yielded a recovery of 95.78% for riboflavin, with a coefficient of variation (CV) of 3.38% (n = 5). The method was also applied to a multi-vitamin supplement for the simultaneous determination of thiamine, riboflavin and pyridoxine. In both cases only simple dilution with buffer followed by centrifugation was required prior to analysis. The resulting square wave voltammetric signals were completely resolved with Ep values of −0.7 V, +0.2 V, and +0.6 V respectively. The recoveries determined for the vitamin B complex in a commercial supplement product were found to be 110%, 114%, and 112% respectively (CV = 7.14%, 6.28%. 5.66% respectively, n = 5)

    Intensity of Brillouin light scattering from spin waves in magnetic multilayers with noncollinear spin configurations: Theory and experiment

    Full text link
    The scattering of photons from spin waves (Brillouin light scattering -- BLS) is a well-established technique for the study of layered magnetic systems. The information about the magnetic state and properties of the sample is contained in the frequency position, width, and intensity of the BLS peaks. Previously [Phys. Rev. B 67, 184404 (2003)], we have shown that spin wave frequencies can be conveniently calculated within the ultrathin film approach, treating the intralayer exchange as an effective bilinear interlayer coupling between thin virtual sheets of the ferromagnetic layers. Here we give the consequent extension of this approach to the calculation of the Brillouin light scattering (BLS) peak intensities. Given the very close relation of the BLS cross-section to the magneto-optic Kerr effect (MOKE), the depth-resolved longitudinal and polar MOKE coefficients calculated numerically via the usual magneto-optic formalism can be employed in combination with the spin wave precessional amplitudes to calculate full BLS spectra for a given magnetic system. This approach allows an easy calculation of BLS intensities even for noncollinear spin configurations including the exchange modes. The formalism is applied to a Fe/Cr/Fe/Ag/Fe trilayer system with one antiferromagnetically coupling spacer (Cr). Good agreement with the experimental spectra is found for a wide variety of spin configurations.Comment: 19 pages, 5 figure

    An electrocatalytic screen-printed amperometric sensor for the selective measurement of thiamine (Vitamin B1) in food supplements

    Get PDF
    An electrocatalytic screen-printed sensor has been investigated for the measurement of the biologically important biomolecule vitamin B1 (thiamine) for the first time in food supplements. Under basic conditions, the vitamin was converted to its electrochemically active thiolate anion species. It was shown that an electrocatalytic oxidation reaction occurred with the screen-printed carbon electrode containing the mediator cobalt phthalocyanine (CoPC-SPCE). This had the advantage of producing an analytical response current at an operating potential of 0 V vs. Ag/AgCl compared to +0.34 V obtained with plain SPCEs. This resulted in improved selectivity and limit of detection. Detailed studies on the underlying mechanism occurring with the sensor are reported in this paper. A linear response was obtained between 0.1 and 20 µg mL −1 , which was suitable for the quantification of the vitamin in two commercial products containing vitamin B1. The mean recovery for a multivitamin tablet with a declared content of 5 mg was 101% (coefficient of variation (CV) of 9.6%). A multivitamin drink, which had a much lower concentration of vitamin B1 (0.22 mg/100 mL), gave a mean recovery of 93.3% (CV 7.2%). These results indicate that our sensor holds promise for quality control of food supplements and other food types

    Evolving outer heliosphere: Large-scale stability and time variations observed by the Interstellar Boundary Explorer

    Get PDF
    The first all-sky maps of Energetic Neutral Atoms (ENAs) from the Interstellar Boundary Explorer (IBEX) exhibited smoothly varying, globally distributed flux and a narrow ribbon of enhanced ENA emissions. In this study we compare the second set of sky maps to the first in order to assess the possibility of temporal changes over the 6 months between views of each portion of the sky. While the large-scale structure is generally stable between the two sets of maps, there are some remarkable changes that show that the heliosphere is also evolving over this short timescale. In particular, we find that (1) the overall ENA emissions coming from the outer heliosphere appear to be slightly lower in the second set of maps compared to the first, (2) both the north and south poles have significantly lower (similar to 10-15%) ENA emissions in the second set of maps compared to the first across the energy range from 0.5 to 6 keV, and (3) the knot in the northern portion of the ribbon in the first maps is less bright and appears to have spread and/or dissipated by the time the second set was acquired. Finally, the spatial distribution of fluxes in the southernmost portion of the ribbon has evolved slightly, perhaps moving as much as 6 degrees (one map pixel) equatorward on average. The observed large-scale stability and these systematic changes at smaller spatial scales provide important new information about the outer heliosphere and its global interaction with the galaxy and help inform possible mechanisms for producing the IBEX ribbon

    In flight performance and first results of FREGATE

    Full text link
    The gamma-ray detector of HETE-2, called FREGATE, has been designed to detect gamma-ray bursts in the energy range [6-400] keV. Its main task is to alert the other instruments of the occurrence of a gamma-ray burst (GRB) and to provide the spectral coverage of the GRB prompt emission in hard X-rays and soft gamma-rays. FREGATE was switched on on October 16, 2000, one week after the successful launch of HETE-2, and has been continuously working since then. We describe here the main characteristics of the instrument, its in-flight performance and we briefly discuss the first GRB observations.Comment: Invited lecture at the Woods Hole 2001 GRB Conference, 8 pages, 15 figure

    Eukaryotic initiation factor-4E in superficial and muscle invasive bladder cancer and its correlation with vascular endothelial growth factor expression and tumour progression

    Get PDF
    Vascular endothelial growth factor (VEGF) is an important factor mediating tumour angiogenesis. VEGF mRNA is differentially expressed in bladder cancer with high expression in superficial tumours (stage pTaand pT1) contrasting with low expression in muscle invasive tumours (stage ≥ pT2). To investigate mechanisms regulating VEGF expression in bladder cancer, VEGF mRNA and protein were measured in normal bladder (n = 12) and primary bladder cancers (n = 57). VEGF protein levels correlated with mRNA expression in normal bladder (r = 0.68, P = 0.02) and bladder cancer (r = 0.46, P = 0.0007). Whilst VEGF mRNA expression was threefold higher in superficial compared to muscle invasive bladder cancers (P = 0.0001) there was no difference in VEGF protein (P = 0.81). Accordingly, the median protein:mRNA ratios increased more than 15-fold with increasing tumour stage (P< 0.0001) suggesting translational regulation. Expression of the eukaryotic initiation factor-4E (eIF-4E), a factor implicated in the translational regulation of VEGF, was greater in tumours than normal bladder (P< 0.0001) and correlated with VEGF protein:mRNA ratios (n = 43, r = 0.54, P = 0.0004) pointing to its role in the regulation of VEGF. In superficial tumours (n = 37) high expression of eIF-4E was associated with a poor prognosis and reduced stage progression-free survival (P = 0.04, Cox proportional hazards model). The study demonstrates that eIF-4E may be involved in translational regulation of VEGF in bladder cancer and might have a role as a prognostic factor in bladder cancer. © 2000 Cancer Research Campaig

    The hypoxia-inducible genes VEGF and CA9 are differentially regulated in superficial vs invasive bladder cancer

    Get PDF
    Regulation by hypoxia may underlie the expression of vascular endothelial growth factor in bladder cancer. We have compared the distribution of vascular endothelial growth factor mRNA with a hypoxia marker, carbonic anhydrase 9 (CA IX). vascular endothelial growth factor mRNA was analysed by in situ hybridisation and CA IX by immunochemistry in 22 cases of bladder cancer. The relationship of microvessels to the distribution of CA IX was determined. In a separate series of 49 superficial tumours, CA IX immunostaining was compared with clinico-pathological outcome. In superficial and invasive disease there was overlap in the expression of vascular endothelial growth factor and CA IX, CA IX being more widespread. Both were expressed predominantly on the luminal surface, and surrounding areas of necrosis (invasive tumours). Expression of both factors was greater in superficial disease. Expression was absent within ∼80 μm of microvessels. Unlike vascular endothelial growth factor, CA IX did not predict outcome in superficial disease. Differential responses to reoxygenation provide one explanation: vascular endothelial growth factor mRNA declined rapidly, while CA IX expression was sustained for >72 h. Expression of vascular endothelial growth factor mRNA in bladder tumours is consistent with hypoxic regulation and suggests differential regulation in superficial vs invasive disease. The expression of CA IX on the luminal surface justifies investigation of its utility as a therapeutic target/prognostic indicator

    A test of the power law relationship between gamma-ray burst pulse width ratio and energy expected in fireballs or uniform jets

    Full text link
    Recently, under the assumption that the Doppler effect of the relativistically expanding fireball surface is important, Qin et al. showed that in most cases the power law relationship between the pulse width and energy of gamma-ray bursts (GRBs)would exist in a certain energy range. We check this prediction with two GRB samples which contain well identified pulses. A power law anti-correlation between the full pulse width and energy and a power law correlation between the pulse width ratio and energy are seen in the light curves of the majority (around 65%) of bursts of the two samples within the energy range of BATSE, suggesting that these bursts are likely to arise from the emission associated with the shocks occurred on a relativistically expanding fireball surface. For the rest of the bursts, the relationships between these quantities were not predicted previously. We propose to consider other spectral evolutionary patterns or other radiation mechanisms such as a varying synchrotron or Comptonized spectrum to check if the observed relationships for these rest bursts can also be accounted for by the Doppler model. In addition, we find that the upper limits of the width ratio for the two samples do not exceed 0.9, in agrement with what predicted previously by the Doppler model. The plateau/power law/plateau and the peaked features predicted and detected previously by Qin et al. are generally observed, with the exceptions being noticed only in a few cases. According to the distinct values of two power law indices of FWHM and ratio and energy, we divide the bursts into three subsets which are located in different areas of the two indices plane. We suspect that different locations of the two indices might correspond to different mechanisms.Comment: 16 pages, 7 figures, MNRAS accepte
    corecore