2,094 research outputs found

    Configuration development study of the X-24C hypersonic research airplane

    Get PDF
    Bottom line results were made of a three-phase study to determine the feasibility of designing, building, and operating, and maintaining an air-launched high performance aircraft capable of cruising at speeds up to Mach 8 for short durations. The results show that Lockalloy heat-sink structure affords the capability for a 'work-horse' vehicle which can serve as an excellent platform for this research. It was further concluded that the performance of a blended wing body configuration surpassed that of a lifting body design for typical X-24C missions. The cost of a two vehicle program, less engines, B-52 modification and contractor support after delivery, can be kept within $70M (in Jan. 1976 dollars)

    Characterization of the Oscillometric Method for Measuring Indirect Blood Pressure

    Get PDF
    In this study, human subjects and dogs were used to determine the ability of the oscillometric method to indicate systolic and diastolic pressure. In the human studies, the auscultatory method was used as the reference. In the animal studies, directly recorded blood pressure was used as the reference. The ability of the sudden increase in cuff pressure oscillations during cuff deflation to indicate systolic pressure was examined and found to overestimate systolic pressure slightly in man, but more in animals. Systolic pressure was encountered when the cuff pressure oscillations were about one half of their maximum amplitude. However, in both man and animals the ratio was not constant; although the range was less in man than in animals. Diastolic pressure was encountered when cuff pressure oscillation amplitude was about 0.8 of the maximal amplitude. This ratio for diastolic pressure was not constant over a range of diastolic pressure. The range of variability was less for man than for the dog

    VetCompass Australia: A National Big Data Collection System for Veterinary Science

    Get PDF
    VetCompass Australia is veterinary medical records-based research coordinated with the global VetCompass endeavor to maximize its quality and effectiveness for Australian companion animals (cats, dogs, and horses). Bringing together all seven Australian veterinary schools, it is the first nationwide surveillance system collating clinical records on companion-animal diseases and treatments. VetCompass data service collects and aggregates real-time, clinical records for researchers to interrogate, delivering sustainable and cost-effective access to data from hundreds of veterinary practitioners nationwide. Analysis of these clinical records will reveal geographical and temporal trends in the prevalence of inherited and acquired diseases, identify frequently prescribed treatments, revolutionize clinical auditing, help the veterinary profession to rank research priorities, and assure evidence-based companion-animal curricula in veterinary schools. VetCompass Australia will progress in three phases: (1) roll-out of the VetCompass platform to harvest Australian veterinary clinical record data; (2) development and enrichment of the coding (data-presentation) platform; and (3) creation of a world-first, real-time surveillance interface with natural language processing (NLP) technology. The first of these three phases is described in the current article. Advances in the collection and sharing of records from numerous practices will enable veterinary professionals to deliver a vastly improved level of care for companion animals that will improve their quality of life

    Two-in-one aortic valve sizing and valvuloplasty conductance balloon catheter

    Get PDF
    BACKGROUND: Inaccurate aortic valve sizing and selection is linked to paravalvular leakage in transcatheter aortic valve replacement (TAVR). Here, a novel sizing valvuloplasty conductance balloon (SVCB) catheter is shown to be accurate, reproducible, unbiased, and provides real-time tool for aortic valve sizing that fits within the standard valvuloplasty procedure. METHODS AND RESULTS: The SVCB catheter is a valvuloplasty device that uses real-time electrical conductance measurements based on Ohm's Law to size the balloon opposed against the aortic valve at any given inflation pressure. Accuracy and repeatability of the SVCB catheter was performed on the bench in phantoms of known dimension and ex vivo in three domestic swine aortic annuli with comparison to computed tomography (CT) and dilator measurements. Procedural workflow and safety was demonstrated in vivo in three additional domestic swine. SVCB catheter measurements had negligible bias or error for bench accuracy considered as the gold standard (Bias: -0.11 ± 0.26 mm; Error: 1.2%), but greater disagreement in ex vivo versus dilators (Bias: -0.3 ± 1.1 mm; Error: 4.5%), and ex vivo versus CT (Bias: -1.0 ± 1.6 mm; Error: 8.7%). The dilator versus CT accuracy showed similar agreement (Bias: -0.9 ± 1.5 mm; Error: 7.3%). Repeatability was excellent on the bench (Bias: 0.02 ± 0.12 mm; Error: 0.5%) and ex vivo (Bias: -0.4 ± 0.9 mm; Error: 4.6%). In animal studies, the device fit well within the procedural workflow with no adverse events or complications. CONCLUSIONS: Due to the clinical relevance of this accurate, repeatable, unbiased, and real-time sizing measurement, the SVCB catheter may provide a useful tool prior to TAVR. These findings merit a future human study

    Integrability of Differential-Difference Equations with Discrete Kinks

    Full text link
    In this article we discuss a series of models introduced by Barashenkov, Oxtoby and Pelinovsky to describe some discrete approximations to the \phi^4 theory which preserve travelling kink solutions. We show, by applying the multiple scale test that they have some integrability properties as they pass the A_1 and A_2 conditions. However they are not integrable as they fail the A_3 conditions.Comment: submitted to the Proceedings of the workshop "Nonlinear Physics: Theory and Experiment.VI" in a special issue di Theoretical and Mathematical Physic

    Proposing new variables for the identification of strategic groups in franchising

    Get PDF
    The identification of strategic groups in the Spanish franchising area is the main aim of this study. The authors have added some new strategic variables (not used before) to the study and have classified franchisors between sectors and distribution strategy. The results reveal the existence of four perfectly differentiated strategic groups (types of franchisors). One of the major implications of this study is that the variables that build a strategic group vary depending on the respective sector the network operates in and its distribution strategy. This fact indicates that including sector and distribution strategy is absolutely necessary to achieve good classifications of franchisor type

    Deterministic mechanical model of T-killer cell polarization reproduces the wandering of aim between simultaneously engaged targets

    Get PDF
    T-killer cells of the immune system eliminate virus-infected and tumorous cells through direct cell-cell interactions. Reorientation of the killing apparatus inside the T cell to the T-cell interface with the target cell ensures specificity of the immune response. The killing apparatus can also oscillate next to the cell-cell interface. When two target cells are engaged by the T cell simultaneously, the killing apparatus can oscillate between the two interface areas. This oscillation is one of the most striking examples of cell movements that give the microscopist an unmechanistic impression of the cell's fidgety indecision. We have constructed a three-dimensional, numerical biomechanical model of the molecular-motor-driven microtubule cytoskeleton that positions the killing apparatus. The model demonstrates that the cortical pulling mechanism is indeed capable of orienting the killing apparatus into the functional position under a range of conditions. The model also predicts experimentally testable limitations of this commonly hypothesized mechanism of T-cell polarization. After the reorientation, the numerical solution exhibits complex, multidirectional, multiperiodic, and sustained oscillations in the absence of any external guidance or stochasticity. These computational results demonstrate that the strikingly animate wandering of aim in T-killer cells has a purely mechanical and deterministic explanation. © 2009 Kim, Maly

    The determinants of election to the United Nations Security Council

    Get PDF
    This is the author's accepted manuscript. The final publication is available at Springer via http://dx.doi.org/10.1007/s11127-013-0096-4.The United Nations Security Council (UNSC) is the foremost international body responsible for the maintenance of international peace and security. Members vote on issues of global importance and consequently receive perks—election to the UNSC predicts, for instance, World Bank and IMF loans. But who gets elected to the UNSC? Addressing this question empirically is not straightforward as it requires a model that allows for discrete choices at the regional and international levels; the former nominates candidates while the latter ratifies them. Using an original multiple discrete choice model to analyze a dataset of 180 elections from 1970 to 2005, we find that UNSC election appears to derive from a compromise between the demands of populous countries to win election more frequently and a norm of giving each country its turn. We also find evidence that richer countries from the developing world win election more often, while involvement in warfare lowers election probability. By contrast, development aid does not predict election
    • …
    corecore