    A supervised texton based approach for automatic segmentation and measurement of the fetal head and femur in 2D ultrasound images

    Get PDF
    This paper presents a supervised texton based approach for the accurate segmentation and measurement of ultrasound fetal head (BPD, OFD, HC) and femur (FL). The method consists of several steps. First, a non-linear diffusion technique is utilized to reduce the speckle noise. Then, based on the assumption that cross sectional intensity profiles of skull and femur can be approximated by Gaussian-like curves, a multi-scale and multi-orientation filter bank is designed to extract texton features specific to ultrasound fetal anatomic structure. The extracted texton cues, together with multi-scale local brightness, are then built into a unified framework for boundary detection of ultrasound fetal head and femur. Finally, for fetal head, a direct least square ellipse fitting method is used to construct a closed head contour, whilst, for fetal femur a closed contour is produced by connecting the detected femur boundaries. The presented method is demonstrated to be promising for clinical applications. Overall the evaluation results of fetal head segmentation and measurement from our method are comparable with the inter-observer difference of experts, with the best average precision of 96.85%, the maximum symmetric contour distance (MSD) of 1.46 mm, average symmetric contour distance (ASD) of 0.53 mm; while for fetal femur, the overall performance of our method is better than the inter-observer difference of experts, with the average precision of 84.37%, MSD of 2.72 mm and ASD of 0.31 mm

    Semi-supervised segmentation of ultrasound images based on patch representation and continuous min cut.

    Get PDF
    Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature

    An Efficient Segmentation Method for Ultrasound Images based on a Semi-supervised Approach and Patch-based Features

    No full text
    Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert

    Calibrated Bayesian neural networks to estimate gestational age and its uncertainty on fetal brain ultrasound images

    No full text
    We present an original automated framework for estimating gestational age (GA) from fetal ultrasound head biometry plane images. A novelty of our approach is the use of a Bayesian Neural Network (BNN), which quantifies uncertainty of the estimated GA. Knowledge of estimated uncertainty is useful in clinical decision-making, and is especially important in ultrasound image analysis where image appearance and quality can naturally vary a lot. A further novelty of our approach is that the neural network is not provided with images pixel size, thus making it rely on anatomical appearance characteristics and not size. We train the network using 9,299 scans from the INTERGROWTH-21st [22] dataset ranging from 14+0 weeks to 42+6 weeks GA. We achieve average RMSE and MAE of 9.6 and 12.5 days respectively over the GA range. We explore the robustness of the BNN architecture to invalid input images by testing with (i) a different dataset derived from routine anomaly scanning and (ii) scans of a different fetal anatomy

    Evaluation and comparison of current fetal ultrasound image segmentation methods for biometric measurements: a grand challenge.

    Get PDF
    This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance