9,185 research outputs found

    Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

    Full text link
    A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type RF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a Helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. In addition, the potential for radiation-induced degradation of the graphite is discussed.Comment: 3 pp. 3rd International Particle Accelerator Conference (IPAC 2012) 20-25 May 2012. New Orleans, Louisian

    Serum N-Terminal Type III Procollagen Propeptide: An Indicator of Growth Hormone Excess and Response to Treatment in Feline Hypersomatotropism

    Get PDF
    BACKGROUND: N‐terminal type III procollagen propeptide (PIIINP) is a biomarker of soft tissue proliferation. Hypersomatotropism (HS) is associated with soft tissue proliferation. HYPOTHESIS: Serum PIIINP is increased in cats with HS and decreases with effective treatment, and may be an additional tool in the diagnosis and treatment of feline HS. ANIMALS: Cats with uncomplicated diabetes mellitus (DM; n = 30) and with HS‐induced DM (HSDM; n = 30). Pre‐ and posttreatment samples were available from 5 cats undergoing radiotherapy (RT) and 16 cats undergoing hypophysectomy (HPX). METHODS: Retrospective and prospective cross‐sectional study. Analytical performance of a serum PIIINP ELISA was assessed and validated for use in cats. PIIINP and insulin‐like growth factor 1 (IGF‐1) radioimmunoassays (RIA) were performed pre‐ and post‐treatment in cats with DM and HSDM. PIIINP and IGF‐1 were compared between cats treated by RT and HPX. RESULTS: Serum PIIINP concentrations were significantly higher (P < .001) in HSDM cats (median, 19.6 ng/mL; range, 1.7–27.9) compared to DM cats (median, 5.0 ng/mL; range, 2.1–10.4). A cut‐off of 10.5 ng/mL allowed differentiation between DM and HSDM cats with 87% sensitivity and 100% specificity (area under the curve [AUC], 0.91; 95% confidence interval [CI], 0.82‐1). After RT, PIIINP increased significantly (P = .043) with no significant change in IGF‐1 concentrations. After HPX, serum PIIINP (P = .034) and IGF‐1 concentrations (P < .001) decreased significantly. CONCLUSION AND CLINICAL IMPORTANCE: PIIINP concentrations are increased in cats with untreated HSDM compared to those with DM, demonstrating the effect of excess GH on soft tissue. PIIINP concentrations decreased after HPX in most HSDM cats

    Experimental characterization of deployable trusses and joints

    Get PDF
    The structural dynamic properties of trusses are strongly affected by the characteristics of joints connecting the individual beam elements. Joints are particularly significant in that they are often the source of nonlinearities and energy dissipation. While the joints themselves may be physically simple, direct measurement is often necessary to obtain a mathematical description suitable for inclusion in a system model. Force state mapping is a flexible, practical test method for obtaining such a description, particularly when significant nonlinear effects are present. It involves measurement of the relationship, nonlinear or linear, between force transmitted through a joint and the relative displacement and velocity across it. An apparatus and procedure for force state mapping are described. Results are presented from tests of joints used in a lightweight, composite, deployable truss built by the Boeing Aerospace Company. The results from the joint tests are used to develop a model of a full 4-bay truss segment. The truss segment was statically and dynamically tested. The results of the truss tests are presented and compared with the analytical predictions from the model

    Prospective evaluation of a protocol for transitioning porcine lente insulintreated diabetic cats to human recombinant protamine zinc insulin

    Get PDF
    Objectives The objective was to evaluate a nadir-led protocol for transitioning porcine lente insulin suspension (PLIS)-treated diabetic cats onto human recombinant protamine zinc insulin (PZIR). Methods Recently diagnosed (<5 months) diabetic cats, treated with PLIS q12h for 6 weeks, were recruited. Fructosamine, 24 h blood glucose curve (BGC), quality of life assessment (DIAQoL-pet score) and Diabetic Clinical Score (DCS) were assessed at enrolment (PLIS-treated) and 2, 4 and 12 weeks after transitioning to PZIR (starting dose 0.2-0.7 U/kg q12h). Short duration of insulin action was defined as <9 h. Linear mixed effects modelling assessed for change in fructosamine, mean blood glucose (MBG) during BGCs, DIAQoL-pet score, DCS and q12h insulin dose. McNemar's tests compared the proportion of cats with hypoglycaemia at week 0 (PLIS-treated) and week 4 (PZIR-treated). Results Twenty-two cats were recruited. Median PLIS dose at enrolment was 0.5 U/kg (interquartile range 0.3-0.7 U/kg) q12h, equalling median PZIR starting dose (0.5 U/kg; interquartile range 0.3-0.7 U/kg q12h). Transitioning was followed by significant decreases in fructosamine (P = 0.00007), insulin dose (P = 0.02), DCS (P = 8.1 x 10(-8)) and DIAQoL-pet score (P = 0.003), indicating improved quality of life. MBG did not alter significantly (P = 0.1). Five cats (22.7%) achieved remission. Hypoglycaemia was recorded in 30/190 12 h BGCs (15.8%) and five cats experienced clinical hypoglycaemia. The proportion of cats with hypoglycaemia did not differ between PLIS (week 0) and PZIR (week 4) (P = 1.0). Duration of action was analysed in 19 cats. Six cats (31.6%) showed short duration of action on PLIS, compared with two cats (10.5%) after 4 weeks on PZIR. All six cats with short PLIS duration showed duration of 9 h on PZIR. Conclusions and relevance Used alongside a low-carbohydrate diet, transitioning to PZIR was associated with significantly improved clinical signs and quality of life, with some cats achieving remission. Transition to PZIR should be considered for cats with short duration of action on PLIS

    Feline hypersomatotropism and acromegaly tumorigenesis: a potential role for the AIP gene

    Get PDF
    Acromegaly in humans is usually sporadic, however up to 20% of familial isolated pituitary adenomas are caused by germline sequence variants of the aryl-hydrocarbon-receptor interacting protein (AIP) gene. Feline acromegaly has similarities to human acromegalic families with AIP mutations. The aim of this study was to sequence the feline AIP gene, identify sequence variants and compare the AIP gene sequence between feline acromegalic and control cats, and in acromegalic siblings. The feline AIP gene was amplified through PCR using whole blood genomic DNA from 10 acromegalic and 10 control cats, and 3 sibling pairs affected by acromegaly. PCR products were sequenced and compared with the published predicted feline AIP gene. A single nonsynonymous SNP was identified in exon 1 (AIP:c.9T > G) of two acromegalic cats and none of the control cats, as well as both members of one sibling pair. The region of this SNP is considered essential for the interaction of the AIP protein with its receptor. This sequence variant has not previously been reported in humans. Two additional synonymous sequence variants were identified (AIP:c.481C > T and AIP:c.826C > T). This is the first molecular study to investigate a potential genetic cause of feline acromegaly and identified a nonsynonymous AIP single nucleotide polymorphism in 20% of the acromegalic cat population evaluated, as well as in one of the sibling pairs evaluated

    Spectral changes during dipping in low-mass X-ray binaries due to highly-ionized absorbers

    Full text link
    X-ray observations have revealed that many microquasars and low-mass X-ray binaries (LMXBs) exhibit narrow absorption features identified with resonant absorption from Fe XXV and Fe XXVI and other abundant ions. In many well studied systems there is evidence for blue-shifts, indicating outflowing plasmas. We succesfully model the changes in both the X-ray continuum and the Fe absorption features during dips from all the bright dipping LMXBs observed by XMM-Newton (EXO 0748-676, XB 1254-690, X 1624-490, MXB 1659-298, 4U 1746-371 and XB 1916-053) as resulting primarily from an increase in column density and a decrease in the ionization state of a highly-ionized absorber in a similar way as was done for 4U 1323-62. This implies that the complex spectral changes in the X-ray continua observed from the dip sources as a class can be most simply explained primarily by changes in the highly ionized absorbers present in these systems. There is no need to invoke unusual abundances or partial covering of extended emission regions. Outside of the dips, the absorption line properties do not vary strongly with orbital phase. This implies that the ionized plasma has a cylindrical geometry with a maximum column density close to the plane of the accretion disk. Since dipping sources are simply normal LMXBs viewed from close to the orbital plane this implies that ionized plasmas are a common feature of LMXBs.Comment: 19 pages, 11 figures, accepted for publication by Astronomy and Astrophysic

    Cryogenic microstripline-on-Kapton microwave interconnects

    Get PDF
    Simple broadband microwave interconnects are needed for increasing the size of focal plane heterodyne radiometer arrays. We have measured loss and cross-talk for arrays of microstrip transmission lines in flex circuit technology at 297 and 77 K, finding good performance to at least 20 GHz. The dielectric constant of Kapton substrates changes very little from 297 to 77 K, and the electrical loss drops. The small cross-sectional area of metal in a printed circuit structure yields overall thermal conductivities similar to stainless steel coaxial cable. Operationally, the main performance tradeoffs are between crosstalk and thermal conductivity. We tested a patterned ground plane to reduce heat flux.Comment: 3 pages, 3 figures, submitted to The Review of Scientific Instrument
    • 

    corecore