47 research outputs found

    Pulmonary Vein Isolation by High Intensity Focused Ultrasound

    Get PDF
    Pulmonary vein isolation (PVI) using radiofrequency current (RFC) ablation is a potentially curative treatment option for patients with atrial fibrillation (AF). The shortcomings of the RFC technology (technically challenging, long procedure times, complications) steadily kindle the interest in new energy sources and catheter designs. High intensity focused ultrasound (HIFU) has the ability to precisely focus ultrasound waves in a defined area with a high energy density. HIFU balloon catheters (BC) positioned at the PV ostia appear to be an ideal tool to transmit the ablation energy in a circumferential manner to the PV ostia and may therefore bear substantial advantage over conventional ablation catheters in PVI procedures

    Major gaps in the information provided to patients before implantation of cardioverter defibrillators: a prospective patient European evaluation

    Get PDF
    AIMS: Information provided to patients prior to implantable cardioverter-defibrillator (ICD) insertion and their participation in the decision-making process are crucial for understanding ICD function and accepting this lifelong therapy. The aim of this study is to evaluate the extent to which different aspects related to ICD and quality of life were transmitted to patients prior to ICD implantation. METHODS AND RESULTS: Prospective, multicenter European study with an online questionnaire initiated by the European Heart Rhythm Association. The questionnaire was filled-in directly and personally by the ICD patients who were invited to participate. A total of 1809 patients (majority in their 40s-70s, with 624 women, 34.5%) from 10 European countries participated in the study. The median time from first ICD implantation was 5 years (interquartile range 2-10). Overall, 1155 patients (71.5%) felt optimally informed at the time of device implantation, however many respondents received no information about ICD-related complications (n = 801, 49.6%), driving restrictions (n = 718, 44.5%), and possibility of end-of-life ICD deactivation (n = 408, 25.4%). Of note, women were less frequently involved in the decision-making process than men (47.3% vs. 55.9%, P = 0.003) and reported to be less often optimally informed before ICD implantation than men (61.2% vs. 76.8%, P < 0.001). More women mentioned the desire to have learned more about ICD therapy and the benefit/risk balance (45.4% vs. 33.7% of men; P < 0.001). CONCLUSIONS: This patient-based evaluation provides alarming findings on the lack of information provided to patients prior ICD implantation, particularly for women

    Rhythm monitoring, success definition, recurrence, and anticoagulation after atrial fibrillation ablation: results from an EHRA survey

    Get PDF
    Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation

    Regional disparity on patient characteristics and perceptions after implantable cardioverter-defibrillator implantation: results from an EHRA patient survey

    Get PDF
    AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted

    Antithrombotic treatment management in low stroke risk patients undergoing cardioversion of atrial fibrillation <48 h duration: results of an EHRA survey

    Get PDF
    Data supporting the safety of cardioversion (CV) of atrial fibrillation (AF) without anticoagulation in patients with AF duration <48 h are scarce. Observational studies suggest that the risk of stroke in these patients is very low when the definite duration of the AF episode is of <48 h and the clinical risk profile as estimated through the CHA2DS2VASc score is low (a score of 0 for men and 1 for women). As the recent 2020 European Society of Cardiology (ESC) guidelines indication for this clinical scenario is based mainly on consensus, we sent out a survey to assess the current clinical practice on anticoagulation prior to and post-CV in patients with AF <24-48 h duration and low stroke risk across centres in Europe. Of the 136 respondents, half were affiliated to university hospitals (68/136; 50%). Non-university hospitals (50/136; 36%) and private hospitals (2/136; 1.4%) accounted over a third of respondents. The main findings of our survey were (i) heterogeneity in the anticoagulation management both before and post-CV in low stroke-risk patients with AF <48 h, (ii) higher utilization of periprocedural low-molecular-weight heparin than of non-vitamin K antagonist oral anticoagulant, (iii) higher utilization of pre-CV transoesophageal echocardiography for electrical CV than for pharmacological CV regardless of the duration of AF, (iv) high adherence to a 4-week post-CV oral anticoagulant (OAC) therapy, mainly for electrical CV, and finally, (v) perceived higher acceptance of lack of post-CV OAC therapy in patients with <24 h than 24-48 h episode duration. The results obtained in this survey highlight the need for more research providing definitive clarification on the safety of CV without anticoagulation in patients with short duration AF

    Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.

    Get PDF
    BACKGROUND: Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS: We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS: A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS: In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.)

    A worldwide survey on incidence, management and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: The POTTER-AF study.

    Get PDF
    AIMS Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse. METHODS AND RESULTS This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001). CONCLUSIONS Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high

    Phrenic Nerve Injury During Cryoballoon-Based Pulmonary Vein Isolation: Results of the Worldwide YETI Registry.

    Get PDF
    BackgroundCryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce.MethodsThe YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible.ResultsA total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months.ConclusionsThe incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article
    corecore