4,396 research outputs found

    Neurogenesis in an adult avian song nucleus is reduced by decreasing caspase-mediated apoptosis

    Get PDF
    Neuron death and replacement are fundamental components of brain plasticity. Much remains unknown, however, about the mechanistic interaction between neuron death and neurogenesis in adult vertebrates. In seasonally breeding adult male white-crowned sparrows, the song system nucleus HVC loses ∼26% of its neurons via caspase-dependent apoptosis within 4 d after a transition to nonbreeding physiological conditions. To determine whether neuronal death is necessary for the recruitment of new neurons, we infused caspase inhibitors into HVC in vivo and suppressed neurodegeneration for at least 20 d after the transition to nonbreeding conditions. The blockade of HVC neuron death reduced the number and density of new neurons recruited to the ipsilateral HVC by 48 and 29%, respectively, compared with contralateral HVC. Our results are the first to show that reducing neuronal death in the adult brain decreases the recruitment of new neurons

    Electrodynamics of Magnetars III: Pair Creation Processes in an Ultrastrong Magnetic Field and Particle Heating in a Dynamic Magnetosphere

    Full text link
    We consider the details of the QED processes that create electron-positron pairs in magnetic fields approaching and exceeding 10^{14} G. The formation of free and bound pairs is addressed, and the importance of positronium dissociation by thermal X-rays is noted. We calculate the collision cross section between an X-ray and a gamma ray, and point out a resonance in the cross section when the gamma ray is close to the threshold for pair conversion. We also discuss how the pair creation rate in the open-field circuit and the outer magnetosphere can be strongly enhanced by instabilities near the light cylinder. When the current has a strong fluctuating component, a cascade develops. We examine the details of particle heating, and show that a high rate of pair creation can be sustained close to the star, but only if the spin period is shorter than several seconds. The dissipation rate in this turbulent state can easily accommodate the observed radio output of the transient radio-emitting magnetars, and even their infrared emission. Finally, we outline how a very high rate of pair creation on the open magnetic field lines can help to stabilize a static twist in the closed magnetosphere and to regulate the loss of magnetic helicity by reconnection at the light cylinder.Comment: 25 pages, submitted to the Astrophysical Journa

    Development and Testing of a Radial Halbach Magnetic Bearing

    Get PDF
    The NASA John H. Glenn Research Center has developed and tested a revolutionary Radial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Radial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Radial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical applications, manufacturing equipment, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Radial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability

    Radial Halbach Magnetic Bearings

    Get PDF
    Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly reliable noncontact bearings for future high-speed rotary machines that may be used in such applications as aircraft, industrial, and land-vehicle power systems and in some medical and scientific instrumentation systems. Radial Halbach magnetic bearings are based on the same principle as that of axial Halbach magnetic bearings, differing in geometry as the names of these two types of bearings suggest. Both radial and axial Halbach magnetic bearings are passive in the sense that unlike most other magnetic bearings that have been developed in recent years, they effect stable magnetic levitation without need for complex active control. Axial Halbach magnetic bearings were described in Axial Halbach Magnetic Bearings (LEW-18066-1), NASA Tech Briefs, Vol. 32, No. 7 (July 2008), page 85. In the remainder of this article, the description of the principle of operation from the cited prior article is recapitulated and updated to incorporate the present radial geometry. In simplest terms, the basic principle of levitation in an axial or radial Halbach magnetic bearing is that of the repulsive electromagnetic force between (1) a moving permanent magnet and (2) an electric current induced in a stationary electrical conductor by the motion of the magnetic field. An axial or radial Halbach bearing includes multiple permanent magnets arranged in a Halbach array ("Halbach array" is defined below) in a rotor and multiple conductors in the form of wire coils in a stator, all arranged so the rotary motion produces an axial or radial repulsion that is sufficient to levitate the rotor. A basic Halbach array (see Figure 1) consists of a row of permanent magnets, each oriented so that its magnetic field is at a right angle to that of the adjacent magnet, and the right-angle turns are sequenced so as to maximize the magnitude of the magnetic flux density on one side of the row while minimizing it on the opposite side. The advantage of this configuration is that it makes it possible to approach the theoretical maximum force per unit area that could be exerted by a given amount of permanent-magnet material. The configuration is named after physicist Klaus Halbach, who conceived it for use in particle accelerators. Halbach arrays have also been studied for use in magnetic-levitation ("maglev") railroad trains. In a radial Halbach magnetic bearing, the basic Halbach arrangement is modified into a symmetrical arrangement of sector-shaped permanent magnets mounted on the outer cylindrical surface of a drum rotor (see Figure 2). The magnets are oriented to concentrate the magnetic field on their radially outermost surface. The stator coils are mounted in a stator shell surrounding the rotor

    Development and Testing of an Axial Halbach Magnetic Bearing

    Get PDF
    The NASA Glenn Research Center has developed and tested a revolutionary Axial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic thrust bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Axial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Axial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical systems, computer memory systems, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Axial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability

    Central excitability contributes to supramaximal volitional contractions in human incomplete spinal cord injury

    Get PDF
    Individuals with a motor incomplete spinal cord injury (SCI) present clinically with partial control of muscles below the site of the injury, but experience profound weakness which can limit the ability to perform functional tasks such as walking. Interestingly, when individuals with an incomplete SCI are asked to maximally and repeatedly contract their quadriceps muscles, they demonstrate an increase in the peak force generated; individuals without SCI experience a decline in force, or ‘fatigue’. Following these repeated maximal efforts, reflex responses to electrical stimulation over the quadriceps muscle elicited amplified and prolonged, involuntary motor activity. Such responses were not observed prior to the maximal contractions, and were not observed in neurologically intact subjects. This finding suggests that increases in spinal excitability following these maximal efforts may enhance force generating capacity, and provides insight into possible novel therapeutic interventions to restore function following SCI

    Contribution of G Protein Activation to Fluoride Stimulation of Phosphoinositide Hydrolysis in Human Neuroblastoma Cells

    Full text link
    To examine the possibility that NaF enhances phosphoinositide-specific phospholipase C (PIC) activity in neural tissues by a mechanism independent of a guanine nucleotide binding protein (G p ), we have evaluated the contribution of G p activation to NaF-stimulated phosphoinositide hydrolysis in human SK-N-SH neuroblastoma cells. Addition of NaF to intact cells resulted in an increase in the release of inositol phosphates (450% of control values; EC 50 of ∼ 8 m M ). Inclusion of U-73122, an aminosteroid inhibitor of guanine nucleotide-regulated PIC activity in these cells, resulted in a dose-dependent inhibition of NaF-stimulated inositol lipid hydrolysis (IC 50 of ∼ 3.5 Μ M ). When added to digitonin-permeabilized cells, NaF or guanosine-5′- O -thiotriphosphate (GTPΓS) resulted in a three- and sevenfold enhancement, respectively, of inositol phosphate release. In the combined presence of optimal concentrations of NaF and GTPΓS, inositol phosphate release was less than additive, indicative of a common site of action. Inclusion of 2–5 m M concentrations of guanosine-5′- O -(2-thiodiphosphate) (GDPΒS) fully blocked phosphoinositide hydrolysis elicited by GTPΓS, whereas that induced by NaF was partially inhibited (65%). However, preincubation of the cells with GDPΒS resulted in a greater reduction in the ability of NaF to stimulate inositol phosphate release (87% inhibition). Both GTPΓS and NaF-stimulated inositol phosphate release were inhibited by inclusion of 10 Μ M U-73122 (54–71%). The presence of either NaF or GTPΓS also resulted in a marked lowering of the Ca 2+ requirement for activation of PIC in permeabilized cells. These results indicate that in SK-N-SH cells, little evidence exists for direct stimulation of PIC by NaF and that the majority of inositol phosphate release that occurs in the presence of NaF can be attributed to activation of G p .Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65259/1/j.1471-4159.1993.tb13406.x.pd

    Alcohol and Smoking Mediated Modulations in Adaptive Immunity in Pancreatitis

    Get PDF
    Pancreatitis is a condition of pancreatic inflammation driven by injury to the pancreatic parenchyma. The extent of acinar insult, intensity, and type of immune response determines the severity of the disease. Smoking, alcohol and autoimmune pancreatitis are some of the predominant risk factors that increase the risk of pancreatitis by differentially influencing the adaptive immune system. The overall decrease in peripheral lymphocyte (T-, B- and (natural killer T-) NKT-cell) count and increased infiltration into the damaged pancreatic tissue highlight the contribution of adaptive immunity in the disease pathology. Smoking and alcohol modulate the responsiveness and apoptosis of T- and B-cells during pancreatic insult. Acute pancreatitis worsens with smoking and alcohol, leading to the development of systemic inflammatory response syndrome and compensatory anti-inflammatory response syndrome, suggesting the critical role of adaptive immunity in fatal outcomes such as multiple organ dysfunction. The presence of CD4+ and CD8+ T-lymphocytes and perforin-expressing cells in the fibrotic tissue in chronic pancreatitis modulate the severity of the disease. Due to their important role in altering the severity of the disease, attempts to target adaptive immune mediators will be critical for the development of novel therapeutic interventions

    Defect evolution in laser powder bed fusion additive manufactured components during thermo-mechanical testing

    Get PDF
    The mechanical performance of additively manufactured (AM) components remains an issue, limiting the implementation of AM technologies. In this work, a new method is presented, to examine the evolution of defects in an Inconel 718 two-bar test specimen, manufactured by laser powder bed fusion AM, during thermo-mechanical testing. The test was interrupted at specific extensions of the specimen, and X-ray computed tomography measurements performed. This methodology has allowed, for the first time, the evolution of the defects in an AM specimen to be studied during a thermo-mechanical test. The number and size of the defects were found to increase with time as a result of the thermo-mechanical test conditions, and the location and evolution of these defects have been tracked. Defect tracking potentially allows for accurate prediction of failure positions, at the earliest possible stage of a thermo-mechanical test. Ultimately, when the ability to locate defects in this manner is coupled with manipulation of build parameters, laser powder bed fusion practitioners will be able to further optimise the manufacturing procedure in order to produce components of a higher structural integrity

    Systems and methods for delivering dissolved gases into force-main and gravity sewers

    Get PDF
    Disclosed are systems and methods for dissolving gases into a fluid that is passing through a force-main and gravity sewer system. The system includes a dissolution tank having a pressure vessel for containing a liquid and for providing a regulated gas head space above the liquid, an inlet that permits passage of wastewater into the gas head space, and an outlet that permits passage of treated wastewater out of the pressure vessel. The system also includes a gas source in communication with the pressure vessel; a pump for supplying wastewater from a force-main or sewer system sump into the pressure vessel under conditions effective to dissolve oxygen gas in the wastewater; and a discharge device in communication with the outlet of the dissolution tank assembly for discharging treated wastewater
    • …
    corecore