27 research outputs found

    Kennedy Space Center (KSC) Launch Pad Avian Abatement Efforts Including Related KSC Road Kill Reduction Effort

    Get PDF
    While birds might seem harmless, there's a good reason for the concern. During the July 2005 launch of Discovery on mission STS-1 14, a vulture soaring around the launch pad impacted the shuttle's external tank just after liftoff. With a vulture's average weight ranging from 3 to 5 pounds. a strike at a critical point on the Shuttle -- like the nose or wing leading thermal protection panels -- could cause catastrophic damage to the vehicle. The foam chunk that fatefully struck Columbia's wing in 2003 weighed only 1.7 pounds. (Cheryl L. Mansfield "Bye Bye Birdies" 2006) To address this issue, NASA formed an "Avian Abatement Team". The team goal is to have safer Shuttle missions by reducing the vulture population at KSC near the pad area thereby reducing the probability of another vulture strike during a Shuttle launch

    Adaptations in antagonist co-activation: Role in the repeated-bout effect

    Get PDF
    Eccentric exercise results in an adaptation which attenuates muscle damage from subsequent exercise—termed the “repeated-bout effect (RBE).” Purpose: Study examined antagonist co-activation and motor-unit recruitment strategy, assessed via dEMG, concomitant to the RBE. Methods: Nine participants performed 5 sub-maximal isometric trapezoid (ramp-up, hold, ramp-down) contractions at force levels corresponding to 50% and 80% of maximal isometric strength (MVC). Surface EMG signals of the biceps brachii were decomposed into individual motor-unit action potential trains. The relationship between mean firing rate (MFR) of each motor-unit and its recruitment threshold (RT) was examined using linear regression. Eccentric exercise was then performed until biceps brachii MVC had decreased by ~40%. Surface EMG of the biceps and triceps were collected during eccentric exercise. MVC, range-of-motion (ROM), and delayed onset muscle soreness (DOMS) were measured 24-hours, 72-hours, and 1-week following eccentric exercise. Three weeks later all procedures were repeated. Results: Changes in MVC (-32±14% vs -25±10%; p = 0.034), ROM (-11% vs 6%; p = 0.01), and DOMS (31.0±19mm vs 19±12mm; p = 0.015) were attenuated following the second bout of exercise. Triceps EMG was reduced (16.8±9.5% vs. 12.6±7.2%; p = 0.03) during the second bout of eccentric exercise. The slope (-0.60±0.13 vs -0.70±0.18; p = 0.029) and y-intercept (46.5±8.3 vs 53.3±8.8; p = 0.020) of the MFR vs. RT relationship was altered during contractions at 80% of MVC prior to the second bout of eccentric exercise. No changes were observed at 50% of MVC. Conclusion: A reduction in antagonist co-activation during the second bout of eccentric exercise suggests less total force was required to move an identical external load. This finding is supported by the increased negative slope coefficient and an increased y-intercept of the linear relationship between RT and MFR.Funded by University of Oklahoma Graduate College Robberson Grant.Ye

    Measuring vortices : architectural principles in the age of cybernetics

    No full text
    EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans

    No full text
    Characterization of critical power/torque (CP/CT) during voluntary exercise requires maximal effort, making difficult for those with neuromuscular impairments. To address this issue we sought to determine if electrically stimulated intermittent isometric exercise resulted in a critical end-test torque (ETT) that behaved similar to voluntary CT. In the first experiment participants (n = 9) completed four bouts of stimulated exercise at a 3:2 duty cycle, at frequencies of 100, 50, 25 Hz, and a low frequency below ETT (Sub-ETT; ≤ 15 Hz). The second experiment (n = 20) consisted of four bouts at a 2:2 duty cycle—two bouts at 100 Hz, one at an intermediate frequency (15–30 Hz), and one at Sub-ETT. The third experiment (n = 12) consisted of two bouts at 50 Hz at a 3:2 duty* cycle with proximal blood flow occlusion during one of the bouts. ETT torque was similar (p ≥ 0.43) within and among stimulation frequencies in experiment 1. No fatigue was observed during the Sub-ETT bouts (p > 0.05). For experiment 2, ETT was similar at 100 Hz and at the intermediate frequency (p ≥ 0.29). Again, Sub-ETT stimulation did not result in fatigue (p > 0.05). Altering oxygen delivery by altering the duty cycle (3:2 vs. 2:2; p = 0.02) and by occlusion (p < 0.001) resulted in lower ETT values. Stimulated exercise resulted in an ETT that was consistent from day-to-day and similar regardless of initial torque, as long as that torque exceeded ETT, and was sensitive to oxygen delivery. As such we propose it represents a parameter similar to voluntary CT

    Firing rates for individual motor units grouped based upon recruitment threshold.

    No full text
    <p>Mean firing rate for individual motor-units of the biceps brachii separated into groups or bins corresponding to 10% of MVC. Panel A are data from contractions performed at 50% of MVC, Panel B are data from 80% of MVC. Number in brackets above each bar indicate the number of motor-units in each bin. *indicates a significnat difference between bout 1 and bout 2 (p < 0.05). Values are means ± SD.</p

    Example of raw EMG and individual firing incidences.

    No full text
    <p>Example of raw EMG signal collected from the 4 pin sensor during a contraction at 50% of MVC are shown in Panel A. Individual firings incidences of the 25 motor-units detected by the decomposition algorithm are shown in Panel B. Each bar represents the firing time of an action potential. The force tracing from the trapezoid contraction is shown by the overlaid solid line.</p
    corecore