32 research outputs found
Three‐dimensional investigation of an open‐ and a closed‐system Pingo in northwestern Canada
The present study presents three‐dimensional investigations of a hydrostatic pingo in the Mackenzie Delta region and a hydraulic pingo in the Ogilvie Mountains and contributes to a better understanding about the internal structures of the two pingo types. A combined approach using quasi‐three‐dimensional electrical resistivity tomography, ground‐penetrating radar and frost probing allowed a clear delineation of frozen and unfrozen areas in the subsurface. At the hydrostatic pingo a massive ice core as well as a surrounding talik could be detected, but the location of the ice core and the talik differs from previous published assumptions. In contrast to acknowledged theory, at our site the massive ice core is not located in the center of the pingo but at the western edge, whereas the eastern flank is underlain by a talik, which surrounds the massive ice core. At the hydraulic pingo, the expected internal structure could be confirmed and the pathway of upwelling water could also be detected. The combined approach of the applied methods represents the first known three‐dimensional geoelectrical investigation of pingos and provides new insights into the internal structure and architecture of the two different pingo types. The chosen approach allows further conclusions on the formation of these permafrost‐affected landforms.German Research Foundation (DFG)
http://dx.doi.org/10.13039/50110000165
Three‐dimensional investigation of an open‐ and a closed‐system Pingo in northwestern Canada
The present study presents three-dimensional investigations of a hydrostatic pingo in the Mackenzie Delta region and a hydraulic pingo in the Ogilvie Mountains and contributes to a better understanding about the internal structures of the two pingo types. A combined approach using quasi-three-dimensional electrical resistivity tomography, ground-penetrating radar and frost probing allowed a clear delineation of frozen and unfrozen areas in the subsurface. At the hydrostatic pingo a massive ice core as well as a surrounding talik could be detected, but the location of the ice core and the talik differs from previous published assumptions. In contrast to acknowledged theory, at our site the massive ice core is not located in the center of the pingo but at the western edge, whereas the eastern flank is underlain by a talik, which surrounds the massive ice core. At the hydraulic pingo, the expected internal structure could be confirmed and the pathway of upwelling water could also be detected. The combined approach of the applied methods represents the first known three-dimensional geoelectrical investigation of pingos and provides new insights into the internal structure and architecture of the two different pingo types. The chosen approach allows further conclusions on the formation of these permafrost-affected landforms
Geophysical and Sedimentological Investigations of Peatlands for the Assessment of Lithology and Subsurface Water Pathways
Peatlands located on slopes (herein called slope bogs) are typical landscape units in the Hunsrueck, a low mountain range in Southwestern Germany. The pathways of the water feeding the slope bogs have not yet been documented and analyzed. The identification of the different mechanisms allowing these peatlands to originate and survive requires a better understanding of the subsurface lithology and hydrogeology. Hence, we applied a multi-method approach to two case study sites in order to characterize the subsurface lithology and to image the variable spatio-temporal hydrological conditions. The combination of Electrical Resistivity Tomography (ERT) and an ERT-Monitoring and Ground Penetrating Radar (GPR), in conjunction with direct methods and data (borehole drilling and meteorological data), allowed us to gain deeper insights into the subsurface characteristics and dynamics of the peatlands and their catchment area. The precipitation influences the hydrology of the peatlands as well as the interflow in the subsurface. Especially, the geoelectrical monitoring data, in combination with the precipitation and temperature data, indicate that there are several forces driving the hydrology and hydrogeology of the peatlands. While the water content of the uppermost layers changes with the weather conditions, the bottom layer seems to be more stable and changes to a lesser extent. At the selected case study sites, small differences in subsurface properties can have a huge impact on the subsurface hydrogeology and the water paths. Based on the collected data, conceptual models have been deduced for the two case study sites
Internal structure of two alpine rock glaciers investigated by quasi-3-D electrical resistivity imaging
Interactions between different formative processes are reflected in the internal structure of rock glaciers. Therefore, the detection of subsurface conditions can help to enhance our understanding of landform development. For an assessment of subsurface conditions, we present an analysis of the spatial variability of active layer thickness, ground ice content and frost table topography for two different rock glaciers in the Eastern Swiss Alps by means of quasi-3-D electrical resistivity imaging (ERI). This approach enables an extensive mapping of subsurface structures and a spatial overlay between site-specific surface and subsurface characteristics. At Nair rock glacier, we discovered a gradual descent of the frost table in a downslope direction and a constant decrease of ice content which follows the observed surface topography. This is attributed to ice formation by refreezing meltwater from an embedded snow bank or from a subsurface ice patch which reshapes the permafrost layer. The heterogeneous ground ice distribution at Uertsch rock glacier indicates that multiple processes on different time domains were involved in the development. Resistivity values which represent frozen conditions vary within a wide range and indicate a successive formation which includes several advances, past glacial overrides and creep processes on the rock glacier surface. In combination with the observed topography, quasi-3-D ERI enables us to delimit areas of extensive and compressive flow in close proximity. Excellent data quality was provided by a good coupling of electrodes to the ground in the pebbly material of the investigated rock glaciers. Results show the value of the quasi-3-D ERI approach but advise the application of complementary geophysical methods for interpreting the results
Glacier − Permafrost Interaction at a Thrust Moraine Complex in the Glacier Forefield Muragl, Swiss Alps
The internal structures of a moraine complex mostly provide information about the manner in which they develop and thus they can transmit details about several processes long after they have taken place. While the occurrence of glacier–permafrost interactions during the formation of large thrust moraine complexes at polar and subpolar glaciers as well as at marginal positions of former ice sheets has been well understood, their role in the formation of moraines on comparatively small alpine glaciers is still very poorly investigated. Therefore, the question arises as to whether evidence of former glacier–permafrost interactions can still be found in glacier forefields of small alpine glaciers and to what extent these differ from the processes in finer materials at larger polar or subpolar glaciers. To investigate this, electrical resistivity tomography (ERT) and ground-penetrating radar (GPR) surveys were carried out in the area of a presumed alpine thrust moraine complex in order to investigate internal moraine structures. The ERT data confirmed the presence of a massive ice core within the central and proximal parts of the moraine complex. Using GPR, linear internal structures were detected, which were interpreted as internal shear planes due to their extent and orientation. These shear planes lead to the assumption that the moraine complex is of glaciotectonic origin. Based on the detected internal structures and the high electrical resistivity values, it must also be assumed that the massive ice core is of sedimentary or polygenetic origin. The combined approach of the two methods enabled the authors of this study to detect different internal structures and to deduce a conceptual model of the thrust moraine formation
Optimisation of quasi-3D electrical resistivity imaging – application and inversion for investigating heterogeneous mountain permafrost
This study aimed to optimise the application, efficiency and interpretability of quasi-3D resistivity imaging for investigating the heterogeneous permafrost distribution at mountain sites by a systematic forward modelling approach. A three dimensional geocryologic model, representative for most mountain permafrost settings, was developed. Based on this geocryologic model quasi-3D models were generated by collating synthetic orthogonal 2D arrays, demonstrating the effects of array types and electrode spacing on resolution and interpretability of the inversion results. The effects of minimising the number of 2D arrays per quasi-3D grid were tested by enlarging the spacing between adjacent lines and by reducing the number of perpendicular tie lines with regard to model resolution and loss of information value. Synthetic and measured quasi-3D models were investigated with regard to the lateral and vertical resolution, reliability of inverted resistivity values, the possibility of a quantitative interpretation of resistivities and the response of the inversion process on the validity of quasi-3D models. Results show that setups using orthogonal 2D arrays with electrode spacings of 2 m and 3 m are capable of delineating lateral heterogeneity with high accuracy and also deliver reliable data on active layer thickness. Detection of permafrost thickness, especially if the permafrost base is close to the penetration depth of the setups, and the reliability of absolute resistivity values emerged to be a weakness of the method. Quasi-3D imaging has proven to be a promising tool for investigating permafrost in mountain environments especially for delineating the often small-scale permafrost heterogeneity, and therefore provides an enhanced possibility for aligning permafrost distribution with site specific surface properties and morphological settings
Internal structure and palsa development at Orravatnsrústir Palsa Site (Central Iceland), investigated by means of integrated resistivity and ground‐penetrating radar methods
The natural cyclical development of palsas makes it difficult to use visible signs of decay as reference points for environmental change. Thus, to determine the actual development stage of a palsa, investigations of the internal structure are crucial. Our study presents 2‐D and 3‐D electrical resistivity imaging (ERI) and 2‐D ground‐penetrating radar (GPR) results, measurements of surface and subsurface temperatures, and of the soil matric potential from Orravatnsrústir Palsa Site in Central Iceland. By a joint interpretation of the results, we deduce the internal structure (i.e., thickness of thaw zone and permafrost, ice/water content) of five palsas of different size and shape. The results differentiate between initial and mature development stages and show that palsas of different development stages can exist in close proximity. While internal characteristics indicate undisturbed development of four palsas, one palsa shows indications of environmental change. Our study shows the value of the multimethod geophysical approach and introduces measurements of the soil matric potential as a promising method to assess the current state of the subsurface
Permafrost and glaciers: perspectives for the Earth and planetary sciences — another step forward
No abstract availabl