141 research outputs found

    Occurrence of the Portevin Le-Chatelier effect in open-cell microcellular Al-2 wt% Mg

    Get PDF
    Microcellular open-cell metal foams with pores of 75 or 400 pm in diameter and made of pure Al or Al-2 wt% Mg are tested in compression. The aluminum foam exhibits a typical smooth plastic flow and a positive strain rate sensitivity, whereas plastic instabilities and a negative strain rate sensitivity appear in the stress-strain curves of the Al-2 wt Mg foams, indicating the presence of the Portevin Le-Chatelier (PLC) effect. The effect is further confirmed by acoustic emission analysis.Taken together, the data indicate that the PLC effect is caused in this material by the sudden collective deformation of many struts across the material. (C) 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved

    A systematic review on the use of quantitative imaging to detect cancer therapy adverse effects in normal-appearing brain tissue

    Get PDF
    Cancer therapy for both central nervous system (CNS) and non-CNS tumors has been previously associated with transient and long-term cognitive deterioration, commonly referred to as ‘chemo fog’. This therapy-related damage to otherwise normal-appearing brain tissue is reported using post-mortem neuropathological analysis. Although the literature on monitoring therapy effects on structural magnetic resonance imaging (MRI) is well established, such macroscopic structural changes appear relatively late and irreversible. Early quantitative MRI biomarkers of therapy-induced damage would potentially permit taking these treatment side effects into account, paving the way towards a more personalized treatment planning. This systematic review (PROSPERO number 224196) provides an overview of quantitative tomographic imaging methods, potentially identifying the adverse side effects of cancer therapy in normal-appearing brain tissue. Seventy studies were obtained from the MEDLINE and Web of Science databases. Studies reporting changes in normal-appearing brain tissue using MRI, PET, or SPECT quantitative biomarkers, related to radio-, chemo-, immuno-, or hormone therapy for any kind of solid, cystic, or liquid tumor were included. The main findings of the reviewed studies were summarized, providing also the risk of bias of each study assessed using a modified QUADAS-2 tool. For each imaging method, this review provides the methodological background, and the benefits and shortcomings of each method from the imaging perspective. Finally, a set of recommendations is proposed to support future research

    Diffusion study by IR micro-imaging of molecular uptake and release on mesoporous zeolites of structure type CHA and LTA

    Get PDF
    The presence of mesopores in the interior of microporous particles may significantly improve their transport properties. Complementing previous macroscopic transient sorption experiments and pulsÚd field gradient NMR self-diffusion studies with such materials, the present study is dedicated to an in-depth study of molecular uptake and release on the individual particles of mesoporous zeolitic specimens, notably with samples of the narrow-pore structure types, CHA and LTA. The investigations are focused on determining the time constants and functional dependences of uptake and release. They include a systematic variation of the architecture of the mesopores and of the guest molecules under study as well as a comparison of transient uptake with blocked and un-blocked mesopores. In addition to accelerating intracrystalline mass transfer, transport enhancement by mesopores is found to be, possibly, also caused by a reduction of transport resistances on the particle surfaces. © 2013 by the authors; licensee MDPI, Basel, Switzerland.118181sciescopu

    Improved adherence with once-daily versus twice-daily dosing of mometasone furoate administered via a dry powder inhaler: a randomized open-label study

    Get PDF
    Background Poor adherence with prescribed asthma medication is a major barrier to positive treatment outcomes. This study was designed to determine the effect of a once-daily administration of mometasone furoate administered via a dry powder inhaler (MF-DPI) on treatment adherence compared with a twice-daily administration. Methods This was a 12-week open-label study designed to mimic an actual clinical setting in patients ≄12 years old with mild-to-moderate persistent asthma. Patients were randomized to receive MF-DPI 400 ÎŒg once-daily in the evening or MF-DPI 200 ÎŒg twice-daily. Adherence was assessed primarily using the number of actual administered doses reported from the device counter divided by the number of scheduled doses. Self-reports were also used to determine adherence. Health-related quality of life, healthcare resource utilization, and days missed from work or school were also reported. Results 1233 patients were randomized. The mean adherence rates, as measured by the automatic dose counter, were significantly better (P < 0.001) with MF-DPI 400 ÎŒg once-daily in the evening (93.3%) than with MF-DPI 200 ÎŒg twice-daily (89.5%). Mean adherence rates based on self-reports were also significantly better (P < 0.001) with MF-DPI 400 ÎŒg QD PM (97.2%) than with MF-DPI 200 ÎŒg twice-daily (95.3%). Adherence rates were lower in adolescents (12-17 years old). Health-related quality of life improved by 20% in patients using MF-DPI once-daily in the evening and by 14% in patients using MF-DPI twice-daily. Very few (<8%) patients missed work/school. Conclusion Mean adherence rates were greater with a once-daily dosing regimen of MF-DPI than with a twice-daily dosing regimen. This trial was completed prior to the ISMJE requirements for trial registration

    Advanced MR techniques for preoperative glioma characterization: Part 1

    Get PDF
    Preoperative clinical magnetic resonance imaging (MRI) protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation or lack thereof. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this first part, we discuss dynamic susceptibility contrast and dynamic contrast-enhanced MRI, arterial spin labeling, diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting. The second part of this review addresses magnetic resonance spectroscopy, chemical exchange saturation transfer, susceptibility-weighted imaging, MRI-PET, MR elastography, and MR-based radiomics applications. Evidence Level: 3 Technical Efficacy: Stage 2

    Improving the hyperpolarization of (31)p nuclei by synthetic design

    Get PDF
    Traditional (31)P NMR or MRI measurements suffer from low sensitivity relative to (1)H detection and consequently require longer scan times. We show here that hyperpolarization of (31)P nuclei through reversible interactions with parahydrogen can deliver substantial signal enhancements in a range of regioisomeric phosphonate esters containing a heteroaromatic motif which were synthesized in order to identify the optimum molecular scaffold for polarization transfer. A 3588-fold (31)P signal enhancement (2.34% polarization) was returned for a partially deuterated pyridyl substituted phosphonate ester. This hyperpolarization level is sufficient to allow single scan (31)P MR images of a phantom to be recorded at a 9.4 T observation field in seconds that have signal-to-noise ratios of up to 94.4 when the analyte concentration is 10 mM. In contrast, a 12 h 2048 scan measurement under standard conditions yields a signal-to-noise ratio of just 11.4. (31)P-hyperpolarized images are also reported from a 7 T preclinical scanner

    Roadmap on holography

    Get PDF
    From its inception holography has proven an extremely productive and attractive area of research. While specific technical applications give rise to 'hot topics', and three-dimensional (3D) visualisation comes in and out of fashion, the core principals involved continue to lead to exciting innovations in a wide range of areas. We humbly submit that it is impossible, in any journal document of this type, to fully reflect current and potential activity; however, our valiant contributors have produced a series of documents that go no small way to neatly capture progress across a wide range of core activities. As editors we have attempted to spread our net wide in order to illustrate the breadth of international activity. In relation to this we believe we have been at least partially successful
    • 

    corecore