90 research outputs found
The BRAIN experiment, a bolometric interferometer dedicated to the CMB B-mode measurement
We present the BRAIN Experiment, a project of B-mode experiment using a novel
technology, bolometric interferometry. This technique is a promising
alternative to direct imaging experiments since it combines the advantages of
interferometry in terms of systematic effects handling and those of bolometry
in terms of sensitivity. We briefly introduce some of the bolometric
interferometry key concepts and difficulties. We then give the specifications
of the BRAIN future detector. A first module of the final instrument is planned
to be installed at Dome C in 2010. We hope to constrain a tensor to scalar
modes ratio of 0.01 with nine modules and one effective year of data. BRAIN is
a collaboration between France, Italy and United Kingdom.Comment: 4 pages, 1 figure. Proceeding of the 43rd "Rencontres de Moriond" on
Cosmology, La Thuile, Italy, March 15 - 22, 200
Bandwidth in bolometric interferometry
Bolometric Interferometry is a technology currently under development that
will be first dedicated to the detection of B-mode polarization fluctuations in
the Cosmic Microwave Background. A bolometric interferometer will have to take
advantage of the wide spectral detection band of its bolometers in order to be
competitive with imaging experiments. A crucial concern is that interferometers
are presumed to be importantly affected by a spoiling effect known as bandwidth
smearing. In this paper, we investigate how the bandwidth modifies the work
principle of a bolometric interferometer and how it affects its sensitivity to
the CMB angular power spectra. We obtain analytical expressions for the
broadband visibilities measured by broadband heterodyne and bolometric
interferometers. We investigate how the visibilities must be reconstructed in a
broadband bolometric interferometer and show that this critically depends on
hardware properties of the modulation phase shifters. Using an angular power
spectrum estimator accounting for the bandwidth, we finally calculate the
sensitivity of a broadband bolometric interferometer. A numerical simulation
has been performed and confirms the analytical results. We conclude (i) that
broadband bolometric interferometers allow broadband visibilities to be
reconstructed whatever the kind of phase shifters used and (ii) that for
dedicated B-mode bolometric interferometers, the sensitivity loss due to
bandwidth smearing is quite acceptable, even for wideband instruments (a factor
2 loss for a typical 20% bandwidth experiment).Comment: 13 pages, 14 figures, submitted to A&
Sensitivity of a Bolometric Interferometer to the CMB power spectrum
Context. The search for B-mode polarization fluctuations in the Cosmic
Microwave Background is one of the main challenges of modern cosmology. The
expected level of the B-mode signal is very low and therefore requires the
development of highly sensitive instruments with low systematic errors. An
appealing possibility is bolometric interferometry. Aims. We compare in this
article the sensitivity on the CMB angular power spectrum achieved with direct
imaging, heterodyne and bolometric interferometry. Methods. Using a simple
power spectrum estimator, we calculate its variance leading to the counterpart
for bolometric interferometry of the well known Knox formula for direct
imaging. Results. We find that bolometric interferometry is less sensitive than
direct imaging. However, as expected, it is finally more sensitive than
heterodyne interferometry due to the low noise of the bolometers. It therefore
appears as an alternative to direct imagers with different and possibly lower
systematic errors, mainly due to the absence of an optical setup in front of
the horns.Comment: 5 pages, 3 figures. This last version matches the published version
(Astronomy and Astrophysics 491 3 (2008) 923-927). Sensitivity of Heterodyne
Interferometers modified by a factor of tw
Bandwidth in Bolometric Interferometry
Context. Bolometric interferometry is a promising new technology with potential applications to the detection of B-mode polarization fluctuations of the cosmic microwave background (CMB). A bolometric interferometer will have to take advantage of the wide spectral detection band of its bolometers to be competitive with imaging experiments. A crucial concern is that interferometers are assumed to be significantly affected by a spoiling effect known as bandwidth smearing.
Aims. We investigate how the bandwidth modifies the work principle of a bolometric interferometer and affects its sensitivity to the CMB angular power spectra.
Methods. We obtain analytical expressions for the broadband visibilities measured by broadband heterodyne and bolometric interferometers. We investigate how the visibilities must be reconstructed in a broadband bolometric interferometer and show that this critically depends on hardware properties of the modulation phase shifters. If the phase shifters produce shifts that are constant with respect to frequency, the instrument works like its monochromatic version (the modulation matrix is not modified), while if they vary (linearly or otherwise) with respect to frequency, one has to perform a special reconstruction scheme, which allows the visibilities to be reconstructed in frequency subbands. Using an angular power spectrum estimator that accounts for the bandwidth, we finally calculate the sensitivity of a broadband bolometric interferometer. A numerical simulation is performed that confirms the analytical results.
Results. We conclude that (i) broadband bolometric interferometers allow broadband visibilities to be reconstructed regardless of the type of phase shifters used and (ii) for dedicated B-mode bolometric interferometers, the sensitivity loss caused by bandwidth smearing is quite acceptable, even for wideband instruments (a factor of 2 loss for a typical 20% bandwidth experiment)
QUBIC: The QU Bolometric Interferometer for Cosmology
One of the major challenges of modern cosmology is the detection of B-mode
polarization anisotropies in the CMB. These originate from tensor fluctuations
of the metric produced during the inflationary phase. Their detection would
therefore constitute a major step towards understanding the primordial
Universe. The expected level of these anisotropies is however so small that it
requires a new generation of instruments with high sensitivity and extremely
good control of systematic effects. We propose the QUBIC instrument based on
the novel concept of bolometric interferometry, bringing together the
sensitivity advantages of bolometric detectors with the systematics effects
advantages of interferometry. Methods: The instrument will directly observe the
sky through an array of entry horns whose signals will be combined together
using an optical combiner. The whole set-up is located inside a cryostat.
Polarization modulation will be achieved using a rotating half-wave plate and
interference fringes will be imaged on two focal planes (separated by a
polarizing grid) tiled with bolometers. We show that QUBIC can be considered as
a synthetic imager, exactly similar to a usual imager but with a synthesized
beam formed by the array of entry horns. Scanning the sky provides an
additional modulation of the signal and improve the sky coverage shape. The
usual techniques of map-making and power spectrum estimation can then be
applied. We show that the sensitivity of such an instrument is comparable with
that of an imager with the same number of horns. We anticipate a low level of
beam-related systematics thanks to the fact that the synthesized beam is
determined by the location of the primary horns. Other systematics should be
under good control thanks to an autocalibration technique, specific to our
concept, that will permit the accurate determination of most of the systematics
parameters.Comment: 12 pages, 10 figures, submitted to Astronomy and Astrophysic
QUBIC: The QU Bolometric Interferometer for Cosmology
Context. One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the Cosmic
Microwave Background. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection
would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is
however so small that it requires a new generation of instruments with high sensitivity and extremely good control of systematic
eects.
Aims. We propose the QUBIC instrument based on the novel concept of bolometric interferometry, bringing together the sensitivity
advantages of bolometric detectors with the systematics eects advantages of interferometry.
Methods. The instrument will directly observe the sky through an array of entry horns whose signals will be combined together
using an optical combiner. The whole set-up is located inside a cryostat. Polarization modulation will be achieved using a rotating
half-wave plate and the images of the interference fringes will be formed on two focal planes (separated by a polarizing grid) tiled
with bolometers.
Results.We show that QUBIC can be considered as a synthetic imager, exactly similar to a usual imager but with a synthesized beam
formed by the array of entry horns. Scanning the sky provides an additional modulation of the signal and improve the sky coverage
shape. The usual techniques of map-making and power spectrum estimation can then be applied. We show that the sensitivity of
such an instrument is comparable with that of an imager with the same number of horns. We anticipate a low level of beam-related
systematics thanks to the fact that the synthesized beam is determined by the location of the primary horns. Other systematics should
be under good control thanks to an autocalibration technique, specific to our concept, that will permit the accurate determination of
most of the systematics parameters
QUBIC: the Q&U Bolometric Interferometer for Cosmology
The primordial B-mode polarisation of the Cosmic Microwave Background is the imprints of the gravitational wave background generated by inflation. Observing the B-mode is up to now the most direct way to constrain the physics of the primordial Universe, especially inflation. To detect these B-modes, high sensitivity is required as well as an exquisite control of systematics effects. To comply with these requirements, we propose a new instrument called QUBIC (Q and U Bolometric Interferometer for Cosmology) based on bolometric interferometry. The control of systematics is obtained with a close-packed interferometer while bolometers cooled to very low temperature allow for high sensitivity. We present the architecture of this new instrument, the status of the project and the self-calibration technique which allows accurate measurement of the instrumental systematic effects
QUBIC VI: cryogenic half wave plate rotator, design and performances
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal
of modern large angular scale cosmic microwave background (CMB) experiments
around the world. A big effort is undergoing with the deployment of many
ground-based, balloon-borne and satellite experiments using different methods
to separate this faint polarized component from the incoming radiation. One of
the largely used technique is the Stokes Polarimetry that uses a rotating
half-wave plate (HWP) and a linear polarizer to separate and modulate the
polarization components with low residual cross-polarization. This paper
describes the QUBIC Stokes Polarimeter highlighting its design features and its
performances. A common systematic with these devices is the generation of large
spurious signals synchronous with the rotation and proportional to the
emissivity of the optical elements. A key feature of the QUBIC Stokes
Polarimeter is to operate at cryogenic temperature in order to minimize this
unwanted component. Moving efficiently this large optical element at low
temperature constitutes a big engineering challenge in order to reduce friction
power dissipation. Big attention has been given during the designing phase to
minimize the differential thermal contractions between parts. The rotation is
driven by a stepper motor placed outside the cryostat to avoid thermal load
dissipation at cryogenic temperature. The tests and the results presented in
this work show that the QUBIC polarimeter can easily achieve a precision below
0.1{\deg} in positioning simply using the stepper motor precision and the
optical absolute encoder. The rotation induces only few mK of extra power load
on the second cryogenic stage (~ 8 K).Comment: Part of a series of 8 papers on QUBIC to be submitted to a special
issue of JCA
- âŠ