    Conduction system pacing: promoting the physiology to prevent heart failure

    Get PDF
    Cardiac conduction system pacing provides physiological ventricular activation by directly stimulating the conduction system. This review describes the two types of conduction system pacing: His bundle pacing (HBP) and left bundle area pacing (LBAP). The most significant advantage of HB pacing is that it can provide a regular, narrow QRS; however, the disadvantages are challenging implantation and a high risk of re-intervention due to lead dislodgement and the development of high pacing threshold. LBAP provides optimum physiological activation of the left ventricle by engaging the left bundle/fascicular fibers. LBAP is more physiological than traditional RV apical pacing and could be an attractive alternative to conventional cardiac resynchronization therapy (CRT). The advantages of LBAP are a relatively more straightforward implantation technique than HBP, better lead stability and pacing thresholds. HBP and LBAP are more physiological than right ventricular pacing and may be used instead of conventional pacemakers. Both HBP and LBBP are being investigated as alternatives to conventional CRT

    Sex is Associated with Differences in Individual Trajectories of Change in Social Health after Implantable Cardioverter-defibrillator

    Get PDF
    Social health is a dimension of quality of life, and refers to people’s involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. Methods and Results We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: P<0.05; covariance parameters: P<0.10) residual variability in the individual trajectories. In the conditional model, men and women differed significantly in their rates of change in the scores of 3 of the 6 measures. Although men’s mean scores exceeded women’s mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women’s change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men’s by 4.5% to 5.6%. Conclusions Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change. &nbsp

    High-definition mapping of the atria using a novel multipolar mapping catheter in patients with complex adult congenital heart disease

    No full text
    Background The Advisor™ HD Grid Mapping Catheter (Abbott Technologies, Minneapolis, MN) has been recently introduced. Although the clinical use of HD Grid mapping catheter is well described in adults with no congenital heart disease, there is limited data on the feasibility of using the HD Grid multipolar catheter to create voltage and activation mapping in adults with congenital heart disease. The purpose of this study was to evaluate the safety and technical feasibility of using the Advisor™ HD Grid mapping catheter during the catheter ablation of atrial arrhythmias in adults with congenital heart disease. We included 6 consecutive adults with congenital heart disease suffering from atrial arrhythmias in our study. The HD Grid mapping catheter was used to perform voltage and activation mapping. Results Six patients with congenital heart diseases (d-TGA n = 1, Tricuspid atresia n = 1, atrioventricular defect repair n = 1, secundum atrial septal defect n = 1, double-inlet single-ventricle n = 1, Tetralogy of Fallot = 1); majority (84%) male, with the mean age was 35 ± 10 years included in our series. The mean ablation duration and the fluoroscopy time were 789 ± 433 and 502 ± 355 s, respectively. The mean radiation dose was 7.52 ± 9 milliGy/cm2. The HD Grid mapping catheter was used successfully for entire arrhythmia mapping in 5 out of 6 cases. During one procedure, HD Grid mapping catheter could not be used for the entire mapping due to suboptimal reach through baffle puncture. The acute success rate of ablation was 100% with no immediate complications. Conclusions The use of HD Grid mapping catheter is a safe and valuable adjunct to accurately create voltage and activation mapping in ACHD patients undergoing radiofrequency catheter ablation. However, a contact force-sensing ablation catheter should be considered in conjunction to supplement data acquisition in challenging anatomy and substrates.Medicine, Faculty ofCardiology, Division ofMedicine, Department ofReviewedFacult

    Use of 3D mapping system for ablating an accessory pathway associated with coronary sinus diverticulum

    No full text
    Background This is a rare and challenging case of Wolff–Parkinson–White syndrome due to a posteroseptal accessory pathway located in the coronary sinus diverticulum. It is often difficult to precisely locate this type of accessory pathway, and the ablation procedure could be associated with collateral damage to the neighbouring coronary arteries. Case Presentation The patient was a 49-year-old female with Wolff–Parkinson–White syndrome who was referred for catheter ablation. She had had a previous unsuccessful attempt at ablation and had remained symptomatic despite drug therapy. The pre-procedural cardiac computed tomography scan revealed the presence of a diverticulum in the proximal coronary sinus. Using an advanced three-dimensional cardiac mapping system, the electroanatomic map of the diverticulum was created. The accessory pathway potential was identified within the diverticulum preceding the ventricular insertion. The accessory pathway was then successfully ablated using radiofrequency energy. Conclusion We have demonstrated that the advanced three-dimensional cardiac mapping system plays a very important role in guiding clinicians in order to precisely locate and safely ablate this type of challenging accessory pathway.Medicine, Faculty ofCardiology, Division ofReviewedFacult

    Thromboembolic episodes related to atrial arrhythmias in adults with transposition of great arteries

    No full text
    Background: Atrial arrhythmias (AA) are common in adults with congenital heart disease (ACHD). Although Intra-atrial Reentrant Tachycardia (IART) is well described in ACHD, Atrial Fibrillation (AF) is uncommon, but increasingly recognized. Patients with Transposition of the Great Arteries (TGA) and congenitally corrected-TGA (CC-TGA) have a high burden of AA at a relatively young age. However, long-term data of AA and associated thromboembolic risk are lacking in these patients. The prevalence, associated clinical factors, and complications of AA in a longitudinal TGA cohort was studied. Methods: A retrospective cohort study of all TGA patients from a single tertiary care centre was conducted. Data regarding documented atrial arrhythmias, thromboembolic events, and factors associated with thromboembolism were extracted and analyzed. Mean values and standard deviations were calculated for normally distributed continuous variables. When frequencies and means were compared, the chi-squared test and student t-test were used, respectively. Results: One-hundred twenty-five patients with TGA (76 TGA, 49 CC-TGA) were followed for a mean of 20.8 ± 13.2 years. AF was confirmed in 20% (n = 25) and there were 5 (20%) thromboembolic complications within the AF population. AF was associated with an annual thromboembolic event rate of 2.7%/year (stroke/transient ischemic attack 1.7%, systemic embolism 1.0%). Conclusion: AF is relatively common in the TGA ACHD population in long-term follow up. Although annual risk of thromboembolism is low in this young group of patients, life-time cumulative risk is potentially high. TGA patients should be screened actively for AF and appropriate anticoagulation therapy initiated. It is unclear if established risk prediction scores in other non-valvular AF populations may be applicable to this cohort.Medicine, Faculty ofOther UBCNon UBCCardiology, Division ofMedicine, Department ofReviewedFacult

    Non-vitamin K antagonist oral anticoagulants (NOACs) for thromboembolic prevention, are they safe in congenital heart disease? Results of a worldwide study

    No full text
    Background: Current guidelines consider vitamin K antagonists (VKA) the oral anticoagulant agents of choice in adults with atrial arrhythmias (AA) and moderate or complex forms of congenital heart disease, significant valvular lesions, or bioprosthetic valves, pending safety data on non-VKA oral anticoagulants (NOACs). Therefore, the international NOTE registry was initiated to assess safety, change in adherence and quality of life (QoL) associated with NOACs in adults with congenital heart disease (ACHD). Methods: An international multicenter prospective study of NOACs in ACHD was established. Follow-up occurred at 6 months and yearly thereafter. Primary endpoints were thromboembolism and major bleeding. Secondary endpoints included minor bleeding, change in therapy adherence (≥80% medication refill rate, ≥6 out of 8 on Morisky-8 questionnaire) and QoL (SF-36 questionnaire). Results: In total, 530 ACHD patients (mean age 47 SD 15 years; 55% male) with predominantly moderate or complex defects (85%), significant valvular lesions (46%) and/or bioprosthetic valves (11%) using NOACs (rivaroxaban 43%; apixaban 39%; dabigatran 12%; edoxaban 7%) were enrolled. The most common indication was AA (91%). Over a median follow-up of 1.0 [IQR 0.0–2.0] year, thromboembolic event rate was 1.0% [95%CI 0.4–2.0] (n = 6) per year, with 1.1% [95%CI 0.5–2.2] (n = 7) annualized rate of major bleeding and 6.3% [95%CI 4.5–8.5] (n = 37) annualized rate of minor bleeding. Adherence was sufficient during 2 years follow-up in 80–93% of patients. At 1-year follow-up, among the subset of previous VKA-users who completed the survey (n = 33), QoL improved in 6 out of 8 domains (p ≪ 0.05). Conclusions: Initial results from our worldwide prospective study suggest that NOACs are safe and may be effective for thromboembolic prevention in adults with heterogeneous forms of congenital heart disease.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore