    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Simulation-Based Learning: Basics for Anaesthetists

    No full text
    Abstract Simulation training is useful to become familiar with new technology, to practice behaviours and strategies, to acquire routines for specific scenarios, and to reflect on one’s behaviour. Processes that have to function almost automatically (e.g., resuscitation) have to be practised repeatedly until they can be reliably executed even under stress or fatigue. Simulators offer the opportunity to acquire these skills without endangering the patient. Various types of simulators (from pig liver to premature baby simulator) are already being used extensively for this purpose. Significant advantages of this learning environment include the freedom from risk in the event of errors, the repeatability of procedures, the possibility of varying conditions, and the possibility of practising processes with different complexities. Simulators are used in a variety of settings, providing valuable training in non-technical skills and creating awareness of other aspects of human factors. In addition, working with simulators through targeted testing of technology and work processes can help to structure work in hospitals more closely based on human factors. Keywords: Anaesthesia, debriefing, human factors, simulation, simulated patient

    Comparison of ProSeal laryngeal mask airway (PLMA) with cuffed and uncuffed endotracheal tubes in infants

    No full text
    We aimed to compare cuffed and uncuffed endotracheal tubes (ETTs) with ProSealTM laryngeal mask airway (PLMA) in terms of airway security and extubation, starting out from the hypothesis that PLMA will provide alternative airway safety to the endotracheal tubes, and that airway complications will be less observed. After obtaining approval from the local Ethics Committee and parental informed consent, 120 pediatric patients 1-24 months old, American Society of Anesthesiologists physical status I-II, requiring general anesthesia for elective lower abdominal surgery, were randomized into PLMA (Group P, n = 40), cuffed ETT (Group C, n = 40), and uncuffed ETT (Group UC, n = 40) groups. The number of intubation or PLMA insertion attempts was recorded. Each patient’s epigastrium was auscultated for gastric insufflation, leak volumes and air leak fractions (leak volume/inspiratory volume) were recorded. Post-operative adverse events related to airway management were also followed up during the first post-operative hour. Demographic and surgical data were similar among the groups. There were significantly fewer airway manipulations in the Group P than in the other groups (p < 0.01), and leak volume and air leak fractions were greater in the Group UC than in the other two groups (p < 0.01). Laryngospasm was significantly lower in the Group P during extubation and within the first minute of post-extubation than in the other groups (p < 0.01). Based on this study, PLMA may be a good alternative to cuffed and uncuffed ETTs for airway management of infants due to the ease of manipulation and lower incidence of laryngospasm

    A comparison of two different doses of morphine added to spinal bupivacaine for inguinal hernia repair

    Get PDF
    ABSTRACT BACKGROUND AND OBJECTIVES: The aim of this study was to compare the effects of two different doses of intrathecal morphine on postoperative analgesia, postoperative first mobilization and urination times and the severity of side effects. METHODS: After Institutional Ethical Committee approval, 48 ASA I-II patients were enrolled in this randomized double-blinded study. Spinal anesthesia was performed with 0.1 mg (Group I, n = 22) or 0.4 mg (Group II, n = 26) ITM in addition to 7.5 mg heavy bupivacaine. The first analgesic requirement, first mobilization and voiding times, and postoperative side effects were recorded. Statistical analyses were performed using SPSS 15.0 and p < 0.05 was considered as statistically significant. The numeric data were analyzed by thet-test and presented as mean ± SD. Categorical data were analyzed with the chi-square test and expressed as number of patients and percentage. RESULTS: Demographic data were similar among groups. There were no differences related to postoperative pain, first analgesic requirements, and first mobilization and first voiding times. The only difference between two groups was the vomiting incidence. In Group II 23% (n = 6) of the patients had vomiting during the first postoperative 24 h compared to 0% in Group I (p = 0.025). CONCLUSION: For inguinal hernia repairs, the dose of 0.1 mg of ITM provides comparable postoperative analgesia with a dose of 0.4 mg, with significantly lower vomiting incidence when combined with low dose heavy bupivacaine

    Does ultrasonographic volume of the thyroid gland correlate with difficult intubation? An observational study

    Get PDF
    BACKGROUND AND OBJECTIVES: Preoperative ultrasonographic evaluation of the thyroid gland done by surgeons could let us foresee airway management challenges. The aim of this observational study was to evaluate the effects of thyroid-related parameters assessed preoperatively by surgeons via ultrasonography and chest X-ray on intubation conditions. METHODS: Fifty patients undergoing thyroid surgery were enrolled. Thyromental distance, Mallampati score, neck circumference and range of neck movement were evaluated before the operation. Thyroid volume, signs of invasion or compression and tracheal deviation on chest X-ray were also noted. The intubation conditions were assessed with Cormack and Lehane score and the intubation difficulty scale. Statistical analyses were done with SPSS 15.0 software. RESULTS: The mean thyroid volume of the patients was 26.38 &#177; 14 mL. The median intubation difficulty scale was 1 (0-2). Thyromental distance (p = 0.011; r = 0.36; 95% CI 0.582-0.088), Mallampati score (p = 0.041; r = 0.29; 95% CI 0.013-0.526), compression or invasion signs (p = 0.041; r = 0.28; 95% CI 0.006-0.521) and tracheal deviation on chest X-ray (p = 0.041; r = 0.52; 95% CI 0.268-0.702) were correlated with intubation difficulty scale. Also patients were classified into two groups related to their intubation difficulty scale (Group I, n = 19: intubation difficulty scale = 0; Group II, n = 31: 1 < intubation difficulty scale &#8804; 5) and difficult intubation predictors and thyroid-related parameters were compared. Only Mallampati score was significantly different between groups (p = 0.025). CONCLUSION: The thyroid volume is not associated with difficult intubation. However clinical assessment parameters may predict difficult intubation

    Anesthesia management and patient outcomes in robotic assisted laparoscopic surgery: A single center experience

    No full text
    Robotic surgical techniques aimed to improve patient outcomes and satisfy patient outcomes while reducing surgical morbidity and mortality. One of the most performed surgeries, robotic assisted laparoscopic radical prostatectomy (RALRP), is characterized by many factors such as steep Trendelenburg position, and challenging access to the patient. We planned to evaluate anesthesia management and postoperative patient outcomes in RALRP. Patients planned for RALRP between January 2017 and June 2021 were included. Demographic data, additional diseases and Charlson Comorbidity Index (CCI) of the patients were recorded. The methods used in anesthesia maintenance, muscle relaxant and sugammadex dose, postoperative pain treatment protocol, duration of anesthesia and surgery, length of stay (LOS) in ICU or hospital, early postoperative complications and Clavien Dindo Classification (CDC) were evaluated by examining the follow-up forms in the intraoperative and postoperative period. Two hundred and sixteen patients underwent robotic assisted laparoscopic surgery between January 2017 and June 2021 and, 141 of them (65.3%) had RALRP. The mean age of the patients was 62.38±6.94, the body mass index was 27.60±3.94, and the mean CCI was 4.08±0.93. Total intravenous anesthesia (TIVA) (n=108, 76.6%) was mostly used for anesthesia maintenance. The median time spent during anesthesia was 278.5±63.6 minutes. The median time for surgery was 239.5±65.9 minutes. According to the CDC, grade-I was 5.7%, grade-II was 2.1%, grade-IVa 7.8%. The most common complication was acute kidney injury (11, 7.8%), followed by atelectasis (4, 2.8%). 98.6% of all patients were sent to the ward from PACU, except two. The mean LOS in hospital was 4.57±2.34 days. Robotic assisted laparoscopic radical prostatectomy is most performed surgery among all robotic surgeries. We think that, patient optimization and communication between surgeon and anesthesiologist is crucial to avoid the negative effects of steep Trendelenburg position and pneumoperitoneum in terms of improving outcome. [Med-Science 2022; 11(4.000): 1482-6

    Does ultrasonographic volume of the thyroid gland correlate with difficult intubation? An observational study

    No full text
    BACKGROUND AND OBJECTIVES: Preoperative ultrasonographic evaluation of the thyroid gland done by surgeons could let us foresee airway management challenges. The aim of this observational study was to evaluate the effects of thyroid-related parameters assessed preoperatively by surgeons via ultrasonography and chest X-ray on intubation conditions. METHODS: Fifty patients undergoing thyroid surgery were enrolled. Thyromental distance, Mallampati score, neck circumference and range of neck movement were evaluated before the operation. Thyroid volume, signs of invasion or compression and tracheal deviation on chest X-ray were also noted. The intubation conditions were assessed with Cormack and Lehane score and the intubation difficulty scale. Statistical analyses were done with SPSS 15.0 software. RESULTS: The mean thyroid volume of the patients was 26.38 ± 14 mL. The median intubation difficulty scale was 1 (0-2). Thyromental distance (p = 0.011; r = 0.36; 95% CI 0.582-0.088), Mallampati score (p = 0.041; r = 0.29; 95% CI 0.013-0.526), compression or invasion signs (p = 0.041; r = 0.28; 95% CI 0.006-0.521) and tracheal deviation on chest X-ray (p = 0.041; r = 0.52; 95% CI 0.268-0.702) were correlated with intubation difficulty scale. Also patients were classified into two groups related to their intubation difficulty scale (Group I, n = 19: intubation difficulty scale = 0; Group II, n = 31: 1 < intubation difficulty scale ≤ 5) and difficult intubation predictors and thyroid-related parameters were compared. Only Mallampati score was significantly different between groups (p = 0.025). CONCLUSION: The thyroid volume is not associated with difficult intubation. However clinical assessment parameters may predict difficult intubation