38 research outputs found

    EBT2 Dosimetry of X-rays produced by the electron beam from PFMA-3, a Plasma Focus for medical applications

    Full text link
    The electron beam emitted from the back of Plasma Focus devices is being studied as a radiation source for IORT (IntraOperative Radiation Therapy) applications. A Plasma Focus device is being developed to this aim, to be utilized as an X-ray source. The electron beam is driven to impinge on 50 {\mu}m brass foil, where conversion X-rays are generated. Measurements with gafchromic film are performed to analyse the attenuation of the X-rays beam and to predict the dose given to the culture cell in radiobiological experiments to follow.Comment: 10 pages, 14 figure

    Il Nibbio reale Milvus milvus svernante in Italia, sintesi di cinque anni di monitoraggio

    Get PDF
    Beginning in December 2011, CISO has promoted a monitoring project for Red kite\u2019s wintering population in Italy. This paper shows the results of the first five survey seasons, ie from December 2011 to January 2016. The censuses, always done at sunset, covered the eleven Central-Southern regions for which winter roosts were already known. The number of actual kites censuses each winter varied between about 1500 and over 1700 individuals, with strong oscillations for single roosts. The population is mainly concentrated in Basilicata with more than 64% of the entire winter population. Interesting data were also been found in Lazio, Abruzzo and Molise, which altogether host about 25% of the national population. Encouraging data come from Tuscany where, following a reintroduction project, a wintering roost of about 80 units was found. Bad results are from censuses conducted in Campania, Calabria, Sicily and Sardinia, where the population seems to be greatly reduced

    Il Nibbio reale Milvus milvus svernante in Italia, sintesi di cinque anni di monitoraggio

    Get PDF
    Beginning in December 2011, CISO has promoted a monitoring project for Red kite\u2019s wintering population in Italy. This paper shows the results of the first five survey seasons, ie from December 2011 to January 2016. The censuses, always done at sunset, covered the eleven Central-Southern regions for which winter roosts were already known. The number of actual kites censuses each winter varied between about 1500 and over 1700 individuals, with strong oscillations for single roosts. The population is mainly concentrated in Basilicata with more than 64% of the entire winter population. Interesting data were also been found in Lazio, Abruzzo and Molise, which altogether host about 25% of the national population. Encouraging data come from Tuscany where, following a reintroduction project, a wintering roost of about 80 units was found. Bad results are from censuses conducted in Campania, Calabria, Sicily and Sardinia, where the population seems to be greatly reduced

    Data Descriptor: Field-recorded data on the diet of six species of European Hydromantes cave salamanders

    Get PDF
    The availability of data on the feeding habits of species of conservation value may be of great importance to develop analyses for both scientific and management purposes. Stomach flushing is a harmless technique that allowed us to collect extensive data on the feeding habits of six Hydromantes species. Here, we present two datasets originating from a three-year study performed in multiple seasons (spring and autumn) on 19 different populations of cave salamanders. The first dataset contains data of the stomach content of 1,250 salamanders, where 6,010 items were recognized; the second one reports the size of the intact prey items found in the stomachs. These datasets integrate considerably data already available on the diet of the European plethodontid salamanders, being also of potential use for large scale meta-analyses on amphibian diet

    The economic impact of moderate stage Alzheimer's disease in Italy: Evidence from the UP-TECH randomized trial

    Get PDF
    Background: There is consensus that dementia is the most burdensome disease for modern societies. Few cost-of-illness studies examined the complexity of Alzheimer's disease (AD) burden, considering at the same time health and social care, cash allowances, informal care, and out-of-pocket expenditure by families. Methods: This is a comprehensive cost-of-illness study based on the baseline data from a randomized controlled trial (UP-TECH) enrolling 438 patients with moderate AD and their primary caregiver living in the community. Results: The societal burden of AD, composed of public, patient, and informal care costs, was about �20,000/yr. Out of this, the cost borne by the public sector was �4,534/yr. The main driver of public cost was the national cash-for-care allowance (�2,324/yr), followed by drug prescriptions (�1,402/yr). Out-of-pocket expenditure predominantly concerned the cost of private care workers. The value of informal care peaked at �13,590/yr. Socioeconomic factors do not influence AD public cost, but do affect the level of out-of-pocket expenditure. Conclusion: The burden of AD reflects the structure of Italian welfare. The families predominantly manage AD patients. The public expenditure is mostly for drugs and cash-for-care benefits. From a State perspective in the short term, the advantage of these care arrangements is clear, compared to the cost of residential care. However, if caregivers are not adequately supported, savings may be soon offset by higher risk of caregiver morbidity and mortality produced by high burden and stress. The study has been registered on the website www.clinicaltrials.org (Trial Registration number: NCT01700556). Copyright � International Psychogeriatric Association 2015

    Socioeconomic Predictors of the Employment of Migrant Care Workers by Italian Families Assisting Older Alzheimer's Disease Patients: Evidence from the Up-Tech Study

    Get PDF
    Background: The availability of family caregivers of older people is decreasing in Italy as the number of migrant care workers (MCWs) hired by families increases. There is little evidence on the influence of socioeconomic factors in the employment of MCWs. Method: We analyzed baseline data from 438 older people with moderate Alzheimer's disease (AD), and their family caregivers enrolled in the Up-Tech trial. We used bivariate analysis and multilevel regressions to investigate the association between independent variables - education, social class, and the availability of a care allowance - and three outcomes - employment of a MCW, hours of care provided by the primary family caregiver, and by the family network (primary and other family caregivers). Results: The availability of a care allowance and the educational level were independently associated with employing MCWs. A significant interaction between education and care allowance was found, suggesting that more educated families are more likely to spend the care allowance to hire a MCW. Discussion: Socioeconomic inequalities negatively influenced access both to private care and to care allowance, leading disadvantaged families to directly provide more assistance to AD patients. Care allowance entitlement needs to be reformed in Italy and in countries with similar long-term care and migration systems. � 2015 The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved

    The effect of scattering by water on the irradiation of cell cultures for the dosimetric characterization of a new prototype of IORT (Intra-Operative Radiation Therapy) device: Monte Carlo simulation and experimental validation

    No full text
    The electron beam emitted backward by Plasma Focus devices is being considered as a radiation source for IORT applications. Radiobiological investigations have been conducted to assess the potential of this new prototype of IORT device. A standard Xray beam ISO-H60 was used for comparison, irradiating cell cultures in a holder filled with an aqueous solution. The influence of scattering by the culture water and by the walls of the holder was investigated to determine its influence on the dose delivered to the cell culture. MCNPX simulations were run and experimental measurements conducted. The effect of scattering by the holder was found to be negligible; scattering by the culture water was determined to give an increase in dose of the order of 10%

    A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus

    No full text
    The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar R has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented

    Monte Carlo simulation of the dose deposited into GAFCHROMIC\uae film by X-rays produced by the electron beam of PFMA-3

    No full text
    The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for IORT (Intra-Operative Radiation Therapy) applications. A Plasma Focus device is being developed to this aim, to be utilized as an X-ray source. The electron beam is driven to impinge on a 50 μm brass foil, where conversion X-rays are generated. Monte Carlo simulations of the X-ray emission have been conducted with MCNPX, with the purpose of estimating penetration in and dose to human tissue. The electron spectrum had been determined experimentally and is used in the present work as input to the simulations. X-ray emission both from bremsstrahlung and from characteristic lines is predicted. The spectrum is found to be comprised of two components: one peaked at 10 keV and one centred around 50 keV. Doses to film determined from the present simulations are compared to experimental values obtained in a previous work by the authors: the results are found in very good agreement
    corecore