    Accurate magnetic sensor system integrated design

    Get PDF
    Inductive measurement of magnetic fields is a diagnostic technique widely used in several scientific fields, such as magnetically confined fusion, plasma thrusters and particle accelerators, where real time control and detailed characterization of physics phenomena are required. The accuracy of the measured data strongly influences the machine controllability and the scientific results. In the framework of the assembly modifications of the RFX-mod experiment, a complete renew and improvement of the magnetic diagnostic system, from the probes moved inside the vacuum vessel to the integrator modules, has been carried out. In this paper, the whole system making up the magnetic diagnostics is described, following the acquisition chain from the probe to the streamed data and illustrating the requirements and conflicting limitations which affect the different components, in order to provide a comprehensive overview useful for an integrated design of any new systems. The characterization of a prototypical implementation of the whole acquisition chain is presented, focusing on the flexible ADC architecture adopted for providing a purely numerical signal integration, highlighting the advantages that this technology offers in terms of flexibility, compactness and cost effectiveness, along with the limitations found in existing implementation in terms of ADC noise characteristics and their possible solutions

    About the parabolic relation existing between the skewness and the kurtosis in time series of experimental data

    Full text link
    In this work we investigate the origin of the parabolic relation between skewness and kurtosis often encountered in the analysis of experimental time-series. We argue that the numerical values of the coefficients of the curve may provide informations about the specific physics of the system studied, whereas the analytical curve per se is a fairly general consequence of a few constraints expected to hold for most systems.Comment: To appear in Physica Script

    Designing high efficiency glow discharge cleaning systems

    Get PDF
    In this paper we present our studies about the choices of anode design and operational regime in order to get high efficiency glow discharge cleaning of the first wall of a fusion device. We analyzed a database of toroidal and poloidal profiles of the ion current density at the wall, measured by electrostatic probes embedded in RFX-mod first wall tiles, taken in different configurations. The ion current at the wall, both global and local, is in fact strictly connected to the cleaning efficiency, since during glow discharge the wall is physically sputtered by the ions. We found that small size anodes and high in-vessel pressure lead to the peaking of the current profile around the anodes locations, and we experimentally characterized this effect. Instead, we found that anode radial position in the poloidal section has negligible effect on current density profile, even when the anodes are placed at the first wall. Finally, the most convenient operational regime, in terms of pressure and current, has been proposed. Keywords: RFX-mod, Glow discharge, Wall cleaning, Ion current profile, Anode desig

    Statistical features of edge turbulence in RFX-mod from Gas Puffing Imaging

    Get PDF
    Plasma density fluctuations in the edge plasma of the RFX-mod device are measured through the Gas Puffing Imaging Diagnostics. Statistical features of the signal are quantified in terms of the Probability Distribution Function (PDF), and computed for several kinds of discharges. The PDFs from discharges without particular control methods are found to be adequately described by a Gamma function, consistently with the recent results by Graves et al [J.P. Graves, et al, Plasma Phys. Control. Fusion 47, L1 (2005)]. On the other hand, pulses with external methods for plasma control feature modified PDFs. A first empirical analysis suggests that they may be interpolated through a linear combination of simple functions. An inspection of the literature shows that this kind of PDFs is common to other devices as well, and has been suggested to be due to the simultaneous presence of different mechanisms driving respectively coherent bursts and gaussian background turbulence. An attempt is made to relate differences in the PDFs to plasma conditions such as the local shift of the plasma column. A simple phenomenological model to interpret the nature of the PDF and assign a meaning to its parameters is also developed.Comment: 27 pages. Published in PPC

    A multichannel reflectometer for edge density profile measurements at the ICRF antenna in ASDEX upgrade

    Get PDF
    A multichannel reflectometer will be built for the new three-straps ICRF antenna of ASDEX Upgrade (AUG), to study the density behavior in front of it. Ten different accesses to the plasma are available for the three reflectometer channels that can be interchanged without breaking the machine vacuum. Frequency is scanned from 40 GHz to 68 GHz, in 10 mu s, which corresponds to a cut-off density ranging from 10(18) divided by 10(19)m(-3) in the Right cut-off of the X-mode propagation, for standard toroidal magnetic field values of AUG

    The role of clinically significant antiphospholipid antibodies in systemic lupus erythematosus

    Get PDF
    The objective is to investigate the role of clinically significant antiphospholipid antibodies (aPL) in a cohort of systemic lupus erythematosus (SLE) patients. All SLE patients followed for at least 5 years and with available aPL profile at the beginning of the follow-up in our center were studied. Clinically significant aPL were defined as: positive lupus anticoagulant test, anti-cardiolipin and/or anti- β2Glycoprotein I IgG/IgM >99th percentile on two or more occasions at least 12 weeks apart. Patients with and without clinically significant aPL were compared by univariate (Chi square or Fisher's exact test for categorical variables and Student's t or Mann-Whitney test for continuous variables) and multivariate analysis (logistic regression analysis). P values <0.05 were considered significant. Among 317 SLE patients studied, 117 (37%) had a clinically significant aPL profile at baseline. Such patients showed at univariate analysis an increased prevalence of deep venous thrombosis, pulmonary embolism, cardiac valvular disease, cognitive dysfunction and antiphospholipid syndrome (APS), but a reduced prevalence of acute cutaneous lupus and anti-extractable nuclear antigens (ENA) when compared with patients without clinically significant aPL. Multivariate analysis confirmed the association between clinically significant aPL and reduced risk of acute cutaneous lupus [p=0.003, odds ratio (OR) 0.43] and ENA positivity (p<0.001, OR 0.37), with increased risk of cardiac valvular disease (p=0.024, OR 3.1) and APS (p<0.0001, OR 51.12). Triple positivity was the most frequent profile and was significantly associated to APS (p<0.0001, OR 28.43). Our study showed that one third of SLE patients had clinically significant aPL, and that this is associated with an increased risk, especially for triple positive, of APS, and to a different clinical and serological pattern of disease even in the absence of APS

    Lymph-vascular Space Involvement and Outer One-third Myometrial Invasion Are Strong Predictors of Distant Haematogeneous Failures in Patients with Stage I-II Endometrioid-type Endometrial Cancer

    Get PDF
    The aim of this retrospective study was to assess the predictive value of different clinicopathological variables (patient age, tumour size, FIGO grade, myometrial invasion, lymph-vascular space involvement [LVSI], invasion margins, peri-tumour phlogistic infiltrate and mitotic activity) for the risk of distant haematogenous recurrences in patients with endometrioid-type stage Ib-II endometrial cancer. Between August 1990 and April 2005, 259 patients had undergone laparotomy, peritoneal washing, total abdominal hysterectomy and bilateral salpingo-oophorectomy, with or without pelvic +/- para-aortic lymphadenectomy for endometrioid-type endometrial cancer. Thirty-six (13.9%) patients had developed recurrent disease after a median time of 17 months (range, 2-128 months). The relapse had been locoregional in 9, distant in 21 and both locoregional plus distant in 6 cases. This study assessed 12 patients with FIGO stage Ib-II disease who had developed distant haematogenous recurrences and 20 randomly chosen control patients with FIGO stage Ib-II disease who had remained recurrence-free after a median follow-up of 52 months (range, 37-66 months). Adjuvant therapy had been: no further treatment in 15 patients, external pelvic irradiation in 14 patients, adjuvant external pelvic irradiation plus brachytherapy in 2 patients and platinum-based chemotherapy followed by external pelvic irradiation in I patient. The site of distant failure had been the lung in 9 patients, liver in 2 patients and lung plus liver in I patient. A concomitant locoregional relapse (vagina or lymph nodes) had occurred in 3 patients. The median interval between surgery and the development of distant failure had been 16.5 months (range, 5-113 months). On univariate analysis, a higher incidence of FIGO grade 3 (50% versus 10%, p=0.0114), outer one-third myometrial invasion (91.7% versus 35.0%, p=0.0051) and LVSI (75.0.% versus 20.0%, p=0.0022) was found in the patients who had developed distant haematogeneous metastases compared to the recurrence-free women. Multivariate analysis showed that LVSI (p=0.0264) and deep myometrial invasion (p=0.0345) were independent predictive variables for the risk of distant haematogeneous failure. Patients with these pathological findings should be enrolled in randomised trials designed to assess the role of adjuvant chemotherapy alone or combined with sequential and /or concomitant external pelvic irradiation
    • …