59 research outputs found

    Close Encounters in a Pediatric Ward: Measuring Face-to-Face Proximity and Mixing Patterns with Wearable Sensors

    Get PDF
    International audienceBackground Nosocomial infections place a substantial burden on health care systems and represent one of the major issues in current public health, requiring notable efforts for its prevention. Understanding the dynamics of infection transmission in a hospital setting is essential for tailoring interventions and predicting the spread among individuals. Mathematical models need to be informed with accurate data on contacts among individuals. Methods and Findings We used wearable active Radio-Frequency Identification Devices (RFID) to detect face-to-face contacts among individuals with a spatial resolution of about 1.5 meters, and a time resolution of 20 seconds. The study was conducted in a general pediatrics hospital ward, during a one-week period, and included 119 participants, with 51 health care workers, 37 patients, and 31 caregivers. Nearly 16,000 contacts were recorded during the study period, with a median of approximately 20 contacts per participants per day. Overall, 25% of the contacts involved a ward assistant, 23% a nurse, 22% a patient, 22% a caregiver, and 8% a physician. The majority of contacts were of brief duration, but long and frequent contacts especially between patients and caregivers were also found. In the setting under study, caregivers do not represent a significant potential for infection spread to a large number of individuals, as their interactions mainly involve the corresponding patient. Nurses would deserve priority in prevention strategies due to their central role in the potential propagation paths of infections. Conclusions Our study shows the feasibility of accurate and reproducible measures of the pattern of contacts in a hospital setting. The obtained results are particularly useful for the study of the spread of respiratory infections, for monitoring critical patterns, and for setting up tailored prevention strategies. Proximity-sensing technology should be considered as a valuable tool for measuring such patterns and evaluating nosocomial prevention strategies in specific settings

    Protic Ionic Liquids Used as Metal-Forming Green Lubricants for Aluminum: Effect of Anion Chain Length

    Get PDF
    Among the applications for protic ionic liquids (PILs), lubrication is one of the newest and the most promising. In this work, ammonium-based protic ionic liquids were tested as lubricant fluids for aluminum-steel contacts. PILs were synthesized with 2-hydroxyethylamine (2HEA) and a carboxylic acid (formic and pentanoic), aiming to understand the effect of two different anion chain lengths on the lubricant behavior. The synthesized PILs were characterized by RMN, FTIR and TGA. Wear tests, conducted using a ball-on-plate configuration, showed that the increase of the anion carbon chain length in the PIL structure reduced significantly the coefficient of friction value. Besides, after the wear tests, the PILs structural integrity was not affected. In the same way, bending under tension (BUT) tests evidenced that the performance for stamping conditions of the PIL with the longest anion carbon chain was similar to that of the commercial lubricant. Since, both formed a uniform tribofilm, developed the same lubrication regime and the drawing forces values were close and constant. Hence, the ionic liquid obtained with 2HEA and pentanoic acid (2HEAPe) is as suitable as the commercial lubricant for metal forming processes

    Approaches in biotechnological applications of natural polymers

    Get PDF
    Natural polymers, such as gums and mucilage, are biocompatible, cheap, easily available and non-toxic materials of native origin. These polymers are increasingly preferred over synthetic materials for industrial applications due to their intrinsic properties, as well as they are considered alternative sources of raw materials since they present characteristics of sustainability, biodegradability and biosafety. As definition, gums and mucilages are polysaccharides or complex carbohydrates consisting of one or more monosaccharides or their derivatives linked in bewildering variety of linkages and structures. Natural gums are considered polysaccharides naturally occurring in varieties of plant seeds and exudates, tree or shrub exudates, seaweed extracts, fungi, bacteria, and animal sources. Water-soluble gums, also known as hydrocolloids, are considered exudates and are pathological products; therefore, they do not form a part of cell wall. On the other hand, mucilages are part of cell and physiological products. It is important to highlight that gums represent the largest amounts of polymer materials derived from plants. Gums have enormously large and broad applications in both food and non-food industries, being commonly used as thickening, binding, emulsifying, suspending, stabilizing agents and matrices for drug release in pharmaceutical and cosmetic industries. In the food industry, their gelling properties and the ability to mold edible films and coatings are extensively studied. The use of gums depends on the intrinsic properties that they provide, often at costs below those of synthetic polymers. For upgrading the value of gums, they are being processed into various forms, including the most recent nanomaterials, for various biotechnological applications. Thus, the main natural polymers including galactomannans, cellulose, chitin, agar, carrageenan, alginate, cashew gum, pectin and starch, in addition to the current researches about them are reviewed in this article.. }To the Conselho Nacional de Desenvolvimento Cientfíico e Tecnológico (CNPq) for fellowships (LCBBC and MGCC) and the Coordenação de Aperfeiçoamento de Pessoal de Nvíel Superior (CAPES) (PBSA). This study was supported by the Portuguese Foundation for Science and Technology (FCT) under the scope of the strategic funding of UID/BIO/04469/2013 unit, the Project RECI/BBB-EBI/0179/2012 (FCOMP-01-0124-FEDER-027462) and COMPETE 2020 (POCI-01-0145-FEDER-006684) (JAT)

    A randomised study of the impact of the SGLT2 inhibitor dapagliflozin on microvascular and macrovascular circulation

    Get PDF
    BACKGROUND: The sodium–glucose cotransporter 2 inhibitor, dapagliflozin, has been shown to improve diabetic control and reduce blood pressure in patients with type 2 diabetes mellitus. Its effects on micro- and macrovascular structure and function have not yet been reported. METHODS: This was a prospective, single-centre, placebo-controlled, double-blind, randomised crossover phase IIIb study conducted between March 2014 and February 2015. After a 4-week run-in/washout phase, patients (N = 59) received 6 weeks of either dapagliflozin 10 mg or placebo once daily. They then underwent a 1-week washout before crossing over to the other treatment. Changes in retinal capillary flow (RCF) and arteriole remodelling were evaluated using scanning laser Doppler flowmetry, while micro- and macrovascular parameters in the systemic circulation were assessed using pulse wave analysis. RESULTS: Six weeks of dapagliflozin treatment resulted in improvements in diabetes control, including blood glucose and insulin resistance, and reduced office and 24-h ambulatory blood pressure values. RCF decreased from 324 AU at baseline to 308 AU after treatment with dapagliflozin (p = 0.028), while there was little difference after the placebo (318 AU; p = 0.334). Furthermore, the arteriole remodelling that was seen after the placebo phase was not evident after the dapagliflozin phase. Central systolic and diastolic blood pressure values were significantly lower after 6 weeks of dapagliflozin, by 3.0 and 2.2 mmHg, respectively (p = 0.035 and 0.020, respectively vs. baseline). CONCLUSIONS: Six weeks of dapagliflozin treatment resulted in numerous beneficial effects. In addition to achieving superior diabetes control and blood pressure, parameters associated with the early stages of vascular remodelling were also improved. Trial registration http://www.clinicaltrials.gov (NCT02383238
    • 

    corecore