11 research outputs found
Efecto de la composición química en el comportamiento mecánico de recubrimientos galvanizados por inmersión en caliente: una revisión
In recent years, a great interest has been generated in the investigation of galvanized coatings, modifying them in order to improve the performance in the conditions of service. These modifications seek a significant improvement in the properties of the galvanized coating, whether in corrosion resistance, weldability or mechanical properties. The demands generated by the multiple applications of these coatings, where the coated substrate is subjected to plastic deformations (stamping, bending and laminating), requires the greater ductility of the coatings. For this reason, chemical compositions of the immersion baths have been developed, making it possible to considerably modify the microstructure of the coatings and thus their mechanical properties. This work aims to perform a bibliographic review on the chemical composition of the immersion baths, their influence on the microstructure and techniques used to determine the ductility and adhesion in galvanized coatings by hot dip.En los últimos años se ha generado un amplio interés en la investigación de los recubrimientos galvanizados, modificándolos con el fin de mejorar el desempeño en condiciones de servicio. Estas modificaciones buscan una mejora significativa en las propiedades del recubrimiento galvanizado, bien sea en la resistencia a la corrosión, en la soldabilidad o en las propiedades mecánicas. Las exigencias generadas por las múltiples aplicaciones de estos recubrimientos, donde el sustrato recubierto es sometido a deformaciones plásticas (estampado, doblado y laminado), requieren de mayor ductilidad de los recubrimientos. Por esto se han desarrollado composiciones químicas de los baños de inmersión, logrando modificar considerablemente la microestructura de los recubrimientos y por ende sus propiedades mecánicas. Este trabajo tiene como objetivo realizar una revisión bibliográfica sobre la composición química de los baños de inmersión, su influencia en la microestructura y técnicas utilizadas para determinar la ductilidad y adherencia en recubrimientos galvanizados por inmersión en caliente
Producción científica y gestión editorial de la revista Ciencia Unemi
In this article, a characterization of the scientific production and editorial management of the journal Ciencia Unemi was carried out, where the universe of study is composed of its publications in Web of Science (WoS). The objective is to analyze the editorial management of the journal Ciencia Unemi in the period 2008 to 2022 using the bibliometric analysis of production, document typology, language capacity, authorship and collaboration, emphasizing the identification of the main research topics, their relationship and the components that integrate them. The study was descriptive in scope, longitudinal in trend (analyzing changes over time) and retrospective, using quantitative techniques and supported by the theoretical and methodological framework provided by the metric studies of information. To characterize the scientific production of the journal Ciencia Unemi, Web of Science (WoS) was used, since it offers indicators about the trends shown by countries, institutions, disciplines, journals and authors, in terms of production, collaboration and use of the work. It is concluded that the journal constitutes a reference of internationalization and visibility in Ecuadorian science, it is indexed in national and international databases, given the important presence of external production, whose performance drives the growing collaboration among researchers and the downloading of articles carried out predominantly outside national borders. However, this effort must be translated into citations to the journal, where there is a pending issue and several areas of opportunity and strengthening.En este artículo se realizó una caracterización de la producción científica y gestión editorial de la revista Ciencia Unemi, donde el universo de estudio lo componen sus publicaciones en Web of Science (WoS). El objetivo de esta investigación es analizar la gestión editorial de la Revista Ciencia Unemi en el periodo 2008 a 2022 usando el análisis bibliométrico de producción, tipología documental, capacidad idiomática, autoría y colaboración, haciendo énfasis en la identificación de los principales temas de investigación, su relación y los componentes que los integran. Se realizó un estudio de alcance descriptivo, longitudinal de tendencia (analiza cambios a través del tiempo) y retrospectivo, usando técnicas cuantitativas y sustentado en el marco teórico y metodológico provisto por los estudios métricos de la información. Para hacer la caracterización de la producción científica de la revista Ciencia Unemi se recurrió a Web of Science (WoS) dado que ofrece indicadores acerca de las tendencias que muestran los países, instituciones, disciplinas, revistas y autores, en términos de producción, colaboración y uso de la obra. Se concluye que la revista constituye un referente de internacionalización y visibilidad en la ciencia ecuatoriana, está indizada en bases de datos nacionales e internacionales, dada la importante presencia de producción externa, cuyo desempeño impulsa la creciente colaboración entre investigadores y la descarga de los artículos llevada a cabo predominantemente fuera de las fronteras nacionales. Sin embargo, este esfuerzo debe traducirse en citas a la revista, donde hay una asignatura pendiente y diversas áreas de áreas de oportunidad y fortalecimiento
Evaluación de propiedades mecánicas en recubrimientos galvanizados por doble inmersión en caliente sobre acero al carbono
Little is known about the operational conditions, the microstructure and properties of the coatings manufactured by hot double-dip. The objective of this work is to evaluate the mechanical properties of Zn / Zn-5%Al coatings applied by the hot double-dip technique, varying the immersion times in liquid baths. For the evaluation, Vickers microhardness profiles and bending tests were made. The microhardness profiles for different immersion times show similarities, exhibiting great heterogeneity due to the microstructural characteristics. It is observed that increasing the immersion time decreases the critical angle, and the immersion time does not significantly influence the density of confined and unconfined cracks. It is concluded that the ductility of the coatings is influenced by their total thickness, and possibly by the thickness of the different areas and residual stresses, with the samples being coated for a 60 s immersion time, which present better behavior in the bending test.Poco se conoce sobre las condiciones operacionales, la microestructura y propiedades de los recubrimientos fabricados por doble inmersión en caliente. Este trabajo tiene como objetivo evaluar propiedades mecánicas de recubrimientos Zn/Zn-5%Al aplicados por la técnica de doble inmersión en caliente, variando los tiempos de inmersión en los baños líquidos. Para la evaluación se realizaron perfiles de microdureza Vickers y ensayos de doblez. Los perfiles de microdureza para diferentes tiempos de inmersión presentan similitudes, mostrando gran heterogeneidad debido a las características microestructurales. Se observa que al aumentar el tiempo de inmersión disminuye el ángulo crítico y el tiempo de inmersión no influye significativamente en la densidad de grietas confinadas y no confinadas. Se concluye que la ductilidad de los recubrimientos se ve influenciada por el espesor total de los mismos, y posiblemente por el espesor de las diferentes zonas y esfuerzos residuales, siendo las muestras recubiertas con tiempo de inmersión de 60 segundos, las que presentan mejor comportamiento ante el ensayo de doblez
Study of the tensile properties of a biocomposite material reinforced with bamboo short fiber bundles
In the present investigation, the tensile mechanical properties of the isotactic polypropylene (PP) biocomposite material reinforced with randomly oriented short bamboo fiber bundles were determined. Samples of the material with different reinforcement contents (20, 30 and 40%) were prepared, using polypropylene with grafts of maleic anhydride molecules (MAPP) as coupling agent. A group of these samples were subjected to an accelerated thermal aging treatment to evaluate the effect of said treatment on the tensile properties of the biocomposite. Tensile tests were carried out at different deformation rates (10 and 50 mm/min) and an increase in tensile strength (29 to 45 MPa) and elastic modulus (1 to 3 GPa) of the PP with the fiber content was obtained. For different stretching speeds, better resistance at high speeds was obtained. Thermal aging for 24 hours at 100 °C increased the resistance of pure PP. For the biocomposites, a low resistance was obtained in the samples aged in greater time (98 °C, 10 days). Through scanning electron microscopy, a microstructural characterization was carried out that allowed explaining the improvement of the resistance of the fiber reinforced PP, and in some cases, the loss of resistance due to heat treatment.En la presente investigación se determinaron las propiedades mecánicas a tracción del material biocompuesto de polipropileno (PP) isotáctico reforzado con haces de fibras cortas de bambú orientadas al azar. Se prepararon muestras del material con diferentes contenidos de refuerzo (20, 30 y 40%), empleando como agente de acople el polipropileno con injertos de moléculas de anhídrido maleico (MAPP). Un grupo de estas muestras fueron sometidas a un tratamiento de envejecimiento térmico acelerado para evaluar el efecto de dicho tratamiento sobre las propiedades a tensión del biocompuesto. Se realizaron ensayos de tracción a diferentes velocidades de deformación (10 y 50 mm/min) y se obtuvo un aumento de la resistencia a la tracción (de 29 a 45 MPa) y del módulo de elasticidad (de 1 a 3 GPa) del PP con el contenido de fibras. Para diferentes velocidades de estiramiento, se obtuvo una mejor resistencia a altas velocidades. El envejecimiento térmico durante 24 horas a 100 ºC aumentó la resistencia del PP puro. Para los biocompuestos, se obtuvo una baja resistencia en las muestras envejecidas en mayor tiempo (98 ºC, 10 días). A través de la microscopia electrónica de barrido se realizó una caracterización microestructural que permitió explicar el mejoramiento de la resistencia del PP reforzado con fibras, y en algunos casos, la pérdida de resistencia debido al tratamiento térmico
Influence of fiber content and annealing on the thermal properties of a bamboo fiber reinforced biocomposite material
In the present investigation, the effects of fiber content (20, 30 and 40 wt%) and annealing heat treatment on the thermal properties of the biocomposite material formed by an isotactic polypropylene polymeric matrix (iPP) reinforced with short bamboo fibers (PP/BF) were studied. The coupling agent was iPP with grafting of maleic anhydride molecules (MAPP). The Differential Scanning Calorimetry (DSC) technique was used to determine the melting temperature (Tm), crystallization temperature (Tc), and degree of crystallinity (Xc) of the biocomposites. The melting temperature of pure PP was not significantly affected by the presence of bamboo fibers. However, the degree of crystallinity of PP increased with fiber content. The annealing heat treatment caused an increase in the Tm of pure PP and PP/BF. The composite with 20 wt% fiber content (PP/20F) annealed achieved the highest Xc (37,47 %). The Tc of polypropylene increased with the presence of fibers, and the PP/20F composite reached the highest value (115 °C). Also, the study of the Tm of the biocomposites in amorphous state was carried out, and it was observed that the sample with a fiber content of 30 wt% presented an endothermic peak at a temperature of approximately 168 °C.En la presente investigación se estudiaron los efectos del contenido de fibra (20, 30 y 40 wt %) y el tratamiento térmico de recocido sobre las propiedades térmicas del material biocompuesto formado por una matriz polimérica de polipropileno isotáctico (iPP) reforzada con fibras cortas de bambú (PP/FB). El agente de acople fue iPP con injertos de moléculas de anhídrido maleico (MAPP). Se empleó la técnica de calorimetría diferencial de barrido (DSC) para determinar la temperatura de fusión (Tm), la temperatura de cristalización (Tc) y el grado de cristalinidad (Xc) de los biocompuestos. La temperatura de fusión del PP puro no se afectó de manera significativa por la presencia de las fibras de bambú; sin embargo, el grado de cristalinidad del PP aumentó con el contenido de fibra. El tratamiento térmico de recocido provocó un aumento de la Tm del PP puro y del PP/FB. El compuesto con 20 wt% de contenido de fibra (PP/20F) recocido alcanzó el mayor Xc (37,47 %). La Tc del polipropileno aumentó con la presencia de las fibras, y el compuesto PP/20F alcanzó el mayor valor (115 °C). También, se realizó el estudio de la Tm de los biocompuestos en estado amorfo, y se obtuvo que la muestra con un contenido de fibra de 30 wt% presentó un pico endotérmico a una temperatura aproximada de 168 °C
Tribological evaluation under fretting wear of WC-Co-CR and NiCrBSI coatings obtained by thermal spraying
L'usure par frottement est un phénomène destructif qui peut accélérer l'initiation des fissures dans des composantes vibrantes et provoquer une rupture catastrophique. Compte tenu des conditions de chargement, des propriétés du matériau et du milieu environnant, le frottement peut provoquer de l'usure en combinant quatre mécanismes classiques (oxydation, adhésion, fatigue en surface et abrasion). Cette étude porte sur la tenue à l'usure de WC-Co-Cr et Ni-Cr déposé par HVOF sur un substrat d'acier SAE 1045. Les essais ont été conduits sous conditions de lubrification sèche, avec différents chargements cycliques et à amplitude variable. Les revêtements ont été étudiés par MEB, EDS, profilométrie optique 3D. Différents mécanismes d'usure ont été observés en fonction du temps, du chargement et de son amplitude. A long terme, il résulte que l'usure adhésive et par délamination représentent les mécanismes prédominants pour la couche déposée. L'augmentation de la résistance à l'usure induite sur la structure est attribuée à la présence dans la couche déposée des carbures dispersées de Ni et de Cr ou encore à la présence des borures dans la matrice de Ni-Cr. D'autre part, nous avons remarqué que le mécanisme d'usure dépend de la magnitude du chargement appliqué. L'étude numérique du profil de l'empreinte obtenue en profondeur permet d'estimer le volume d'usure. On observe ainsi une bonne corrélation entre les valeurs expérimentales et celles obtenues par profilométrie 3D. Il a été déterminé que, pour une amplitude d'usure constante, le volume d'usure augmente en fonction de la charge appliquée sous des conditions de chargement constante.Fretting wear is a destructive phenomenon that can accelerate crack initiation in vibrating components, leading to premature catastrophic failures. Depending on loading conditions, material properties and environment, fretting can cause fretting wear, which combines all four basic wear mechanisms (oxidative, adhesive, surface fatigue and abrasive). The present study investigates the fretting wear performance of a WC-Co-Cr and Ni-Cr alloy, deposited by HVOF onto a SAE 1045 steel. Tests were conducted under unlubricated dry conditions, at different applied normal loads, cycles and amplitudes. The coatings were studied by means of SEM, EDS and 3D perfilometry. Different wear mechanisms were observed, depending on time, load and amplitude. ln a long term, the adhesive wear and delamination wear were the predominant wear mechanisms for the coating. The increase in the fretting wear resistance provided by the coating Ni-Cr has been attributed to the presence of a large amount of dispersed Ni and Cr carbide and/or borides in the NiCo matrix. Examination of the fretted surfaces by SEM indicates that the uncoated substrate undergoes an abrasive wear mechanism. On the contrary, it has been observed that the wear mechanism of the coating-substrate system depends on the magnitude of the applied load. The numerical integration of the wear scar depth profile curves employed in the present work allows an estimation of the wear volume which is in good agreement with that determined experimentally by means of 3D profilometry. It has been determined that, at a constant wear amplitude the wear volume increases with the applied normal load and that at under constant load conditions
Efecto de la composición química en el comportamiento mecánico de recubrimientos galvanizados por inmersión en caliente: una revisión
In recent years, a great interest has been generated in the investigation of galvanized coatings, modifying them in order to improve the performance in the conditions of service. These modifications seek a significant improvement in the properties of the galvanized coating, whether in corrosion resistance, weldability or mechanical properties. The demands generated by the multiple applications of these coatings, where the coated substrate is subjected to plastic deformations (stamping, bending and laminating), requires the greater ductility of the coatings. For this reason, chemical compositions of the immersion baths have been developed, making it possible to considerably modify the microstructure of the coatings and thus their mechanical properties. This work aims to perform a bibliographic review on the chemical composition of the immersion baths, their influence on the microstructure and techniques used to determine the ductility and adhesion in galvanized coatings by hot dip.En los últimos años se ha generado un amplio interés en la investigación de los recubrimientos galvanizados, modificándolos con el fin de mejorar el desempeño en condiciones de servicio. Estas modificaciones buscan una mejora significativa en las propiedades del recubrimiento galvanizado, bien sea en la resistencia a la corrosión, en la soldabilidad o en las propiedades mecánicas. Las exigencias generadas por las múltiples aplicaciones de estos recubrimientos, donde el sustrato recubierto es sometido a deformaciones plásticas (estampado, doblado y laminado), requieren de mayor ductilidad de los recubrimientos. Por esto se han desarrollado composiciones químicas de los baños de inmersión, logrando modificar considerablemente la microestructura de los recubrimientos y por ende sus propiedades mecánicas. Este trabajo tiene como objetivo realizar una revisión bibliográfica sobre la composición química de los baños de inmersión, su influencia en la microestructura y técnicas utilizadas para determinar la ductilidad y adherencia en recubrimientos galvanizados por inmersión en caliente
Evaluación de propiedades mecánicas en recubrimientos galvanizados por doble inmersión en caliente sobre acero al carbono
Little is known about the operational conditions, the microstructure and properties of the coatings manufactured by hot double-dip. The objective of this work is to evaluate the mechanical properties of Zn / Zn-5%Al coatings applied by the hot double-dip technique, varying the immersion times in liquid baths. For the evaluation, Vickers microhardness profiles and bending tests were made. The microhardness profiles for different immersion times show similarities, exhibiting great heterogeneity due to the microstructural characteristics. It is observed that increasing the immersion time decreases the critical angle, and the immersion time does not significantly influence the density of confined and unconfined cracks. It is concluded that the ductility of the coatings is influenced by their total thickness, and possibly by the thickness of the different areas and residual stresses, with the samples being coated for a 60 s immersion time, which present better behavior in the bending test.Poco se conoce sobre las condiciones operacionales, la microestructura y propiedades de los recubrimientos fabricados por doble inmersión en caliente. Este trabajo tiene como objetivo evaluar propiedades mecánicas de recubrimientos Zn/Zn-5%Al aplicados por la técnica de doble inmersión en caliente, variando los tiempos de inmersión en los baños líquidos. Para la evaluación se realizaron perfiles de microdureza Vickers y ensayos de doblez. Los perfiles de microdureza para diferentes tiempos de inmersión presentan similitudes, mostrando gran heterogeneidad debido a las características microestructurales. Se observa que al aumentar el tiempo de inmersión disminuye el ángulo crítico y el tiempo de inmersión no influye significativamente en la densidad de grietas confinadas y no confinadas. Se concluye que la ductilidad de los recubrimientos se ve influenciada por el espesor total de los mismos, y posiblemente por el espesor de las diferentes zonas y esfuerzos residuales, siendo las muestras recubiertas con tiempo de inmersión de 60 segundos, las que presentan mejor comportamiento ante el ensayo de doblez
Dekretale und Delegatenausfertigung: Die beiden Versionen der Littera Alexanders II. JL 12116 (1171-1172)
El presente trabajo muestra la evaluación del desempeño
de dos aleaciones comerciales de aluminio
anodizadas ante la corrosión y tribocorrosión. Para
el anodizado se emplearon dos tipos de electrolitos
distintos (H2SO4 y H2C2O4), un valor constante de
densidad de corriente y dos tiempos de anodizado (30
y 45 minutos). Usando una de las técnicas de microscopía
electrónica de barrido (MEB) y espectroscopía
por dispersión de la energía de rayos X (EDX) se
caracterizaron las aleaciones y la morfología de las
superficies formadas en las capas de óxido para las
condiciones establecidas. Se encontraron diferencias
notables entre la condición de anodizado (A1) a 45
minutos en H2SO4 para la aleación AA6061, y la
condición de anodizado (D1) para el mismo tiempo
en H2C2O4 para la aleación AA8011. En la condición
de anodizado (A1) se encontró la formación de
la morfología tipo smudge distintiva de la solución
electrolítica utilizada, con un espesor promedio de
capa anódica de 5,95 ± 0,02 µm, mientras que, para
la condición de anodizado (D1) se obtuvo un espesor
de 3,14 ± 0,02 µm, con la aparición de cavidades en
toda la extensión de su superficie. Tanto para los ensayos de corrosión en cámara de
niebla salina, electroquímicos de polarización potenciodinámica
y tribocorrosión, se encontró que el mejor
desempeño fue registrado en la condición de anodizado
(A1), con una menor ganancia promedio de
masa, densidad de corriente de corrosión y coeficiente
de fricción. Todas las condiciones de anodizado mejoraron
el comportamiento ante ensayos de degradación
acelerada, en comparación con las muestras no anodizadas. // In this work were studied two commercial anodized
aluminum alloys under conditions of corrosion and
tribocorrosion. For two different types of anodizing
electrolyte (H2SO4 and H2C2O4), a constant value
of current density and two anodizing time (30 and
45 minutes) were used. Using techniques of Scanning
Electron Microscopy (SEM) with Spectroscopy
Energy Dispersive X-Ray (EDS) coupled, were characterized
the alloys and morphologies of the surfaces
formed in the oxide layers. Results obtained show
large differences between the condition of anodized
(A1) in sulfuric acid for 45 minutes in AA6061 alloy
and anodized condition (D1) for the same time in
oxalic acid for alloy AA8011. For sample (A1), the
results reveals the formation of a morphology named
"smudge" which is characteristic of the electrolytic solution
used and for this case the average thickness was
5,95 ± 0,02 µm. For sample (D1), the average thickness
was 3,14 ± 0,02 µm and revealing the generation
of cavities along all surface area. Both corrosion tests in salt spray chamber, electrochemical
potentiodynamic polarization and tribocorrosion
found that the best behavior was obtained
for sample (A1), with lower, average mass gain, corrosion
current density and friction coefficient. The
performance in all anodizing conditions was improved
comparing against samples without anodized
ESTUDIO DEL DETERIORO CORROSIVO DE COMPONENTES DE ENSAMBLAJE EN TORRES DE TRASMISIÓN DE ALTA TENSIÓN
The objective of this work was to characterize the corrosive deterioration of the galvanizedcomponents of assembly of the structure of an electrical power transmission tower. For this, a visualinspection accompanied by a metallographic analysis, thickness measurement of the galvanized,morphological analysis by scanning electron microscopy (SEM) with chemical microanalysisby dispersive energy (EDX) was carried out. The results obtained show that the metal components evaluated have two clearly differentiable zones in terms of surface tonality: a clear and a dark zone, which indicates the presence of a preferential corrosive deterioration of the coating. The microanalysis by EDX carried out in these zones shows that the damage by corrosion and the consequent loss of thickness of the zinc protective coating of the evaluated components is associated with the presence of atmospheric pollutants. It is concluded that the capacity of protection against corrosion of the galvanized remaining in function of the aggressiveness of the environment to which they are exposed by the proximity of an industrial zone, is one of the main causes of the deterioration.
Keywords: Galvanized, transmission towers, corrosion, contaminants, industrial atmosphere.
References
[1]M. Morcillo, J. Alcántara, I. Díaz, B. Chico, J.Simancas and D. Fuente, “Marine atmospheric corrosion of carbon steels”, Revista de Metalurgia, Vol. 44, no 2, pp 045, 2015.
[2].M. Morcillo, M. Almeida, F. Fragata and Z. Panossian, “Corrosión y Protección de los Metales en Atmosferas de Iberoamérica”, Tomo I, España, Ed. Proyecto CYTED, 2002, pp 779.
[3].F. Cadena, L. Irusta b and M.J. Fernandez-Berridib, “Performance evaluation of alkyd coatings for corrosion protection in urban and industrial environments”, Progress in Organic Coatings, Vol.76, pp 1273- 1278, 2013.
[4].L. Linares, “Evaluación de la corrosividad atmosférica y su efecto en los cables de transmisión eléctrica a 400kV de CVG EDELCA”, Tesis de Maestría. Universidad del Zulia. Maracaibo, Venezuela, 2007.
[5].J. Guerra, A. Castañeda and J. Howland, “Estudio preliminar de la agresividad corrosiva de la atmósfera en el puente de los Caras, Manabí, Ecuador”, Revista CENIC Ciencias Químicas, Vol. 47, pp. 17-29, 2016.
[6].D. J. Pazmiño, “Análisis y diseño estructural de una torre de transmisión eléctrica para el proyecto hidroeléctrico Angamarca-Sinde 32MW, Cantón Pangua, provincia de Cotopaxi”. Tesis de grado. Universidad Central del Ecuador, Ecuador, 2016.
[7]Norma ISO 1463, 2003, “Metallic and oxide coatings-Measurement of coatings thickness-Microscopical Method”, ISO, Genève, Switzerland.
[8]Norma ASTM E 45, 2005, “Standard Test Methods of Determining the Inclusion Content of Steel”, ASTM International, West Conshohocken, PA.
[9]Norma ASTM A -36, 2003, “Standard Specification for Carbon Structural Steel”, ASTM International, West Conshohocken, PA.
[10]Norma ASTM A 123/A, 2000, “Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products”, ASTM International, West Conshohocken, PA.
[11]Norma ASTM A 153, 2003, “Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware”, ASTM International, West Conshohocken, PA.
[12]Y. Rico and E. Carrasquero, “Efecto de la composición química en el comportamiento mecánico de recubrimientos galvanizados por inmersión en caliente: una revisión”, Ingenius, N°18, pp. 30-39, 2017.
[13].M. Morcillo, M. Almeida, F. Fragata and Z. Panossian, “Corrosión y Protección de los Metales en Atmosferas de Iberoamérica”, Tomo II, España, Ed. Proyecto CYTED, pp 441-494. 2002.El objetivo del presente trabajo fue caracterizar el estado de deterioro corrosivo de los componentes galvanizados de ensamblaje de la estructura de una torre de transmisión de energía eléctrica. Para ello se realizó en primera instancia una inspección visual acompañado de un análisis metalográfico,medición de espesor del galvanizado, análisis morfológico por microscopia electrónica de barrido (MEB) con microanálisis químico por energía dispersiva (EDX). Los resultados obtenidos evidencian que los componentes metálicos evaluados presentan dos zonas claramente diferenciables en cuanto a tonalidad superficial: una zona clara y otra oscura, lo que indica la presencia de un deterioró corrosivo preferencial del recubrimiento. Los microanálisis químicos por EDX realizados en estas zonas reflejan que el daño por corrosión y la consecuente pérdida de espesor del recubrimiento protector de zinc de los componentes evaluados está asociado a la presencia de contaminantes atmosféricos. Se concluye que la capacidad de protección contra la corrosión del galvanizado remanente en función de la agresividad del ambiente al cual están expuesto por la cercanía de una zona industrial, es una de las principales causas del deterioro.
Palabras Claves: Galvanizado, torres de trasmisión, corrosión, contaminantes, atmosfera industrial.
Referencias
[1]M. Morcillo, J. Alcántara, I. Díaz, B. Chico, J.Simancas y D. Fuente, “Marine atmospheric corrosion of carbon steels”, Revista de Metalurgia, Vol. 44, no 2, pp 045, 2015.
[2].M. Morcillo, M. Almeida, F. Fragata y Z. Panossian, “Corrosión y Protección de los Metales en Atmosferas de Iberoamérica”, Tomo I, España, Ed. Proyecto CYTED, 2002, pp 779.
[3].F. Cadena, L. Irusta b y M.J. Fernandez-Berridib, “Performance evaluation of alkyd coatings for corrosion protection in urban and industrial environments”, Progress in Organic Coatings, Vol.76, pp 1273- 1278, 2013.
[4].L. Linares, “Evaluación de la corrosividad atmosférica y su efecto en los cables de transmisión eléctrica a 400kV de CVG EDELCA”, Tesis de Maestría. Universidad del Zulia. Maracaibo, Venezuela, 2007.
[5].J. Guerra, A. Castañeda y J. Howland, “Estudio preliminar de la agresividad corrosiva de la atmósfera en el puente de los Caras, Manabí, Ecuador”, Revista CENIC Ciencias Químicas, Vol. 47, pp. 17-29, 2016.
[6].D. J. Pazmiño, “Análisis y diseño estructural de una torre de transmisión eléctrica para el proyecto hidroeléctrico Angamarca-Sinde 32MW, Cantón Pangua, provincia de Cotopaxi”. Tesis de grado. Universidad Central del Ecuador, Ecuador, 2016.
[7]Norma ISO 1463, 2003, “Metallic and oxide coatings-Measurement of coatings thickness-Microscopical Method”, ISO, Genève, Switzerland.
[8]Norma ASTM E 45, 2005, “Standard Test Methods of Determining the Inclusion Content of Steel”, ASTM International, West Conshohocken, PA.
[9]Norma ASTM A -36, 2003, “Standard Specification for Carbon Structural Steel”, ASTM International, West Conshohocken, PA.
[10]Norma ASTM A 123/A, 2000, “Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products”, ASTM International, West Conshohocken, PA.
[11]Norma ASTM A 153, 2003, “Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware”, ASTM International, West Conshohocken, PA.
[12]Y. Rico y E. Carrasquero, “Efecto de la composición química en el comportamiento mecánico de recubrimientos galvanizados por inmersión en caliente: una revisión”, Ingenius, N°18, pp. 30-39, 2017.
[13].M. Morcillo, M. Almeida, F. Fragata y Z. Panossian, “Corrosión y Protección de los Metales en Atmosferas de Iberoamérica”, Tomo II, España, Ed. Proyecto CYTED, pp 441-494. 2002