76 research outputs found

    Evaluation of the primary biliary cholangitis-related serologic profile in a large cohort of Belgian systemic sclerosis patients

    Get PDF
    Background: Systemic sclerosis (SSc) and primary biliary cholangitis (PBC) are autoimmune diseases that may occur concomitantly and are both strongly associated with disease-specific autoantibodies. This study investigated the prevalence and fine specificity of PBC-specific serology (PBC-Ab) and associations with the SSc-subtypes and SSc-specific antibodies as well as the association with cholestatic liver enzymes. Furthermore, three different techniques for the detection of PBC-Ab were compared. Methods: Serum of 184 Belgian SSc patients with a known SSc-antibody profile, was analyzed for PBC-Ab (antimitochondrial antibodies [AMA], anti-Gp210, anti-Sp100 and anti-PML) using indirect immunofluorescence (IIF) analysis on human epithelioma-2000 (HEp-2000) cells (ANA-IIF, Immunoconcepts) and liver-kidney-stomach tissue sections (IIF-LKS) (Menarini), and a line immunoblot (LB) (Eurolmmun). Alkaline phosphatase/gamma-glutamyl transferase (ALP/GGT) were evaluated at time of first sampling (t0) and after 3 years of follow-up (t3). Results: PBC-Ab were present in 13% of patients and significantly correlated with centromere antibodies (anti-CENP-B), but not correlated with the limited cutaneous SSc subgroup (lcSSc). The most frequent reactivities were AMA (11%, with 9% AMA-M2) and Sp-100 antibodies (5%), showing a major overlap. There was no relevant association between the presence of PBC-Ab and ALP or GGT elevation at t0 nor at t3. Detection of AMA with IIF-LKS is comparable to LB. ANA-IIF screening was less sensitive compared to LB. Conclusions: A wide range of PBC-Ab is detectable in SSc in the absence of cholestatic liver enzyme elevations, even after 3 years of follow-up. However, as these antibodies may precede PBC-disease up to 10 years further prospective follow-up of our cohort will be necessary

    The importance of detecting anti-DFS70 in routine clinical practice : comparison of different care settings

    Get PDF
    Background: Screening for antinuclear antibodies by indirect immunofluorescence (ANA-IIF) is essential in the diagnostic workup of ANA-associated autoimmune rheumatic diseases (AARDs). However, also healthy individuals may test positive, making the interpretation challenging. Recent reports suggest that dense fine speckled 70 antibodies (anti-DFS70) may facilitate this challenge. Here, we investigate their clinical importance based on data from four Belgian laboratories (one primary, two secondary and one tertiary care). Methods: At least one specific DFS70 assay (DFS70 IgG ELISA or lineblot [Euroimmun, full length antigen] and/or DFS70 IgG CLIA [Inova Diagnostics, truncated antigen]) was performed on four consecutive cohorts of homogeneous-like ANA-IIF samples (n = 697). Co-occurrence with AARD-specific ANA and clinical information were documented in the anti-DFS70-positive samples. Results: Using a combination of solid phase techniques, we found between 7.6% and 26% anti-DFS70 in the different cohorts. Focusing on anti-DFS70 CLIA-positive samples without co-occurrence of AARD-specific ANA, we observed a trend towards lower frequency in tertiary (8% [p = 0.0786]) and secondary care (12% [p = 0.1275] and 6% [p < 0.001]) compared to primary care (21%). Moreover, in this specific subpopulation, AARD was less frequent (0%-50% compared to 6%-77% in the total anti-DFS70-positive group). Conclusions: Anti-DFS70 prevalence depends on the applied assay and care setting. Our data suggest that, for an ANA-IIF-positive patient, it is rather the absence of AARD-associated ANA and clinical symptoms that contribute to the exclusion of AARD than the presence of anti-DFS70. Nevertheless, isolated anti-DFS70 helps to clarify positive ANA-IIF results, especially if pretest probability for AARD is low

    Propylthioiracil induced ANCA-associated vasculitis in a 14 year-old girl

    Get PDF
    Background: Antineutrophil cytoplasmic antibodies (ANCAs) are the serologic hallmark of ANCA-associated primary small-vessel vasculitides (AAVs), but these antibodies have also been described in other autoimmune diseases such as inflammatory bowel diseases. Furthermore, different drugs are linked to the induction of ANCA, including propylthiouracil (PTU). However progression into clinical overt vasculitis is less common. Case-diagnosis/treatment: We describe the case of a young girl with Graves' disease presenting with fatigue, fever, episcleritis and arthritis. The unexpected double myeloperoxidase/proteinase 3-ANCA positivity triggered a multidisciplinary diagnostic work-up and resulted in the diagnosis of a clinically overt PTU-induced AAV. After PTU-withdrawal and treatment with high-dose corticosteroids, a favorable clinical and biochemical evolution was obtained. Conclusions: The use of PTU in the management of hyperthyroidism is not considered first-line treatment in Europe and is even less commonly used in children. Nevertheless, pediatricians should be aware of the possibility of PTU-induced AAV, especially in the presence of multiple ANCA reactivities. Therefore, the use of this drug should be weighed carefully in children

    Impact of blood storage and sample handling on quality of high dimensional flow cytometric data in multicenter clinical research

    Get PDF
    Obtaining reliable and reproducible high quality data in multicenter clinical research settings requires design of optimal standard operating procedures. While the need for standardization in sample processing and data analysis is well-recognized, the impact of sample handling in the pre-analytical phase remains underestimated. We evaluated the impact of sample storage time (approximate to transport time) and temperature, type of anticoagulant, and limited blood volume on reproducibility of flow cytometric studies. EDTA and Na-Heparin samples processed with the EuroFlow bulk lysis protocol, stained and stored at 4 degrees C showed fairly stable expression of cell surface markers and distribution of the major leukocyte populations for up to 72 h. Additional sample fixation (1% PFA, Fix & Perm) did not have any beneficial effects. Blood samples stored for < 24 h at room temperature before processing and staining seemed suitable for reliable immunophenotyping, although losses in absolute cell numbers were observed. The major losses were observed in myeloid cells and monocytes, while lymphocytes seemed less affected. Expression of cell surface markers and population distribution were more stable in Na-Heparin blood than in EDTA blood. However, storage of Na-Heparin samples was associated with faster decrease in leukocyte counts over time. Whole blood fixation strategies (Cyto-Chex, TransFix) improved long-term population distribution, but were detrimental for expression of cellular markers. The main conclusions from this study on healthy donor blood samples were successfully confirmed in EDTA clinical (patient) blood samples with different time delays until processing. Finally, we recognized the need for adjustments in bulk lysis in case of insufficient blood volumes. Despite clear overall conclusions, individual markers and cell populations had different preferred conditions. Therefore, specific guidelines for sample handling should always be adjusted to the clinical application and the main target leukocyte population

    Improved standardization of flow cytometry diagnostic screening of primary immunodeficiency by software-based automated gating

    Get PDF
    Background Multiparameter flow cytometry (FC) is essential in the diagnostic work-up and classification of primary immunodeficiency (PIDs). The EuroFlow PID Orientation tube (PIDOT) allows identification of all main lymphocyte subpopulations in blood. To standardize data analysis, tools for Automated Gating and Identification (AG&I) of the informative cell populations, were developed by EuroFlow. Here, we evaluated the contribution of these innovative AG&I tools to the standardization of FC in the diagnostic work-up of PID, by comparing AG&I against expert-based (EuroFlow-standardized) Manual Gating (MG) strategy, and its impact on the reproducibility and clinical interpretation of results. Methods FC data files from 44 patients (13 CVID, 12 PID, 19 non-PID) and 26 healthy donor (HD) blood samples stained with PIDOT were analyzed in parallel by MG and AG&I, using Infinicyt (TM) software (Cytognos). For comparison, percentage differences in absolute cell counts/mu L were calculated for each lymphocyte subpopulation. Data files showing differences >20% were checked for their potential clinical relevance, based on age-matched percentile (p5-p95) reference ranges. In parallel, intra- and inter-observer reproducibility of MG vs AG&I were evaluated in a subset of 12 samples. Results The AG&I approach was able to identify the vast majority of lymphoid events (>99%), associated with a significantly higher intra- and inter-observer reproducibility compared to MG. For most HD (83%) and patient (68%) samples, a high degree of agreement (<20% numerical differences in absolute cell counts/mu L) was obtained between MG and the AG&I module. This translated into a minimal impact (<5% of observations) on the final clinical interpretation. In all except three samples, extended expert revision of the AG&I approach revealed no error. In the three remaining samples aberrant maturation and/or abnormal marker expression profiles were seen leading in all three cases to numerical alarms by AG&I. Conclusion Altogether, our results indicate that replacement of MG by the AG&I module would be associated with a greater reproducibility and robustness of results in the diagnostic work-up of patients suspected of PID. However, expert revision of the results of AG&I of PIDOT data still remains necessary in samples with numerical alterations and aberrant B- and T-cell maturation and/or marker expression profiles

    Optimization and testing of dried antibody tube: The EuroFlow LST and PIDOT tubes as examples

    Get PDF
    Within EuroFlow, we recently developed screening tubes for hematological malignancies and immune deficiencies. Pipetting of antibodies for such 8-color 12-marker tubes however is time-consuming and prone to operational mistakes. We therefore evaluated dried formats of the lymphocytosis screening tube (LST) and of the primary immune deficiency orientation tube (PIDOT). Both tubes were evaluated on normal and/or on patient samples, comparing the mean fluorescence intensity of specific lymphocyte populations. Our data show that the dried tubes and liquid counterparts give highly comparable staining results, particularly when analyzed in multidimensional plots. In addition, the use of dried tubes may result in a reduced staining variability between different samples and thereby contributes to the generation of more robust data. Therefore, by using ready-to-use reagents in a dried single test tube format, the laboratory efficiency and quality will be improved

    Belgian rare diseases plan in clinical pathology : identification of key biochemical diagnostic tests and establishment of reference laboratories and financing conditions

    Get PDF
    BackgroundOne objective of the Belgian Rare Diseases plan is to improve patients' management using phenotypic tests and, more specifically, the access to those tests by identifying the biochemical analyses used for rare diseases, developing new financing conditions and establishing reference laboratories.MethodsA feasibility study was performed from May 2015 until August 2016 in order to select the financeable biochemical analyses, and, among them, those that should be performed by reference laboratories. This selection was based on an inventory of analyses used for rare diseases and a survey addressed to the Belgian laboratories of clinical pathology (investigating the annual analytical costs, volumes, turnaround times and the tests unavailable in Belgium and outsourced abroad). A proposal of financeable analyses, financing modalities, reference laboratories' scope and budget estimation was developed and submitted to the Belgian healthcare authorities. After its approval in December 2016, the implementation phase took place from January 2017 until December 2019.ResultsIn 2019, new reimbursement conditions have been published for 46 analyses and eighteen reference laboratories have been recognized. Collaborations have also been developed with 5 foreign laboratories in order to organize the outsourcing and financing of 9 analyses unavailable in Belgium.ConclusionsIn the context of clinical pathology and rare diseases, this initiative enabled to identify unreimbursed analyses and to meet the most crucial financial needs. It also contributed to improve patients' management by establishing Belgian reference laboratories and foreign referral laboratories for highly-specific analyses and a permanent surveillance, quality and financing framework for those tests

    Current laboratory and clinical practices in reporting and interpreting anti?nuclear antibody indirect immunofluorescence (ANA IIF) patterns: results of an international survey

    Get PDF
    Background: The International Consensus on Antinuclear Antibody (ANA) Patterns (ICAP) has recently proposed nomenclature in order to harmonize ANA indirect immunofluorescence (IIF) pattern reporting. ICAP distinguishes competent-level from expert-level patterns. A survey was organized to evaluate reporting, familiarity, and considered clinical value of ANA IIF patterns. Methods: Two surveys were distributed by European Autoimmunity Standardization Initiative (EASI) working groups, the International Consensus on ANA Patterns (ICAP) and UK NEQAS to laboratory professionals and clinicians. Results: 438 laboratory professionals and 248 clinicians from 67 countries responded. Except for dense fine speckled (DFS), the nuclear competent patterns were reported by>85% of the laboratories. Except for rods and rings, the cytoplasmic competent patterns were reported by>72% of laboratories. Cytoplasmic IIF staining was considered ANA positive by 55% of clinicians and 62% of laboratory professionals, with geographical and expertise-related differences. Quantification of fluorescence intensity was considered clinically relevant for nuclear patterns, but less so for cytoplasmic and mitotic patterns. Combining IIF with specific extractable nuclear antigens (ENA)/dsDNA antibody testing was considered most informative. Of the nuclear competent patterns, the centromere and homogeneous pattern obtained the highest scores for clinical relevance and the DFS pattern the lowest. Of the cytoplasmic patterns, the reticular/mitochondria-like pattern obtained the highest scores for clinical relevance and the polar/Golgi-like and rods and rings patterns the lowest. Conclusion: This survey confirms that the major nuclear and cytoplasmic ANA IIF patterns are considered clinically important. There is no unanimity on classifying DFS, rods and rings and polar/Golgi-like as a competent pattern and on reporting cytoplasmic patterns as ANA IIF positive
    corecore