11 research outputs found

    Continuous low flow ascites drainage through the urinary bladder via the Alfapump system in palliative patients with malignant ascites.

    Get PDF
    BACKGROUND Malignant Ascites (MA) is a therapeutic dilemma significantly impairing patients' quality of life (QoL). The Sequana Medical alfapump System (AP), a subcutaneous, externally rechargeable, implantable device, continually draining ascites via the urinary bladder, has been well established in liver cirrhosis, but not yet in MA. The AP-system was evaluated in cancer patients in reducing the need for large volume paracentesis (LVP). METHODS A retrospective multicentre evaluation of all eligible patients who received an AP for MA-palliation was performed. AP was evaluated for its ability to reduce LVP and cross-correlated with adverse events (AE), survival and retrospective physician-reported QoL. RESULTS Seventeen patients with median age of 63 years (range: 18-81), 70.6% female, across 7 primary tumour types were analysed. Median duration of AP-implantation was 60 min (range: 30-270) and median post-implantation hospital stay: 4 days (range: 2-24). Twelve protocol-defined AE occurred in 5 patients (29.4%): 4 kidney failures, 4 pump/catheter-related blockages, 3 infections/peritonitis and 1 wound dehiscence. Median ascitic volume (AV) pumped daily was 303.6 ml/day (range:5.6-989.3) and median total AV drained was 28 L (range: 1-638.6). Median patient post-AP-survival was 111 days (range:10-715) and median pump survival was 89 days (range: 0-715). Median number of paracenteses was 4 (range: 1-15) per patient pre-implant versus 1 (range: 0-1) post-implant (p = 0.005). 71% of patients were reported to have an improvement of at least one physician reported QoL-parameters. CONCLUSIONS AP appears to be effective in palliating patients with MA by an acceptable morbidity profile. Its broader implementation in oncology services should be further explored. TRIAL REGISTRATION NCT03200106; June 27, 2017

    Consensus care recommendations for alfapump® in cirrhotic patients with refractory or recurrent ascites

    Get PDF
    BACKGROUND: The alfapump® is an implantable class III medical device that pumps ascitic fluid from the peritoneal space to the urinary bladder from where it is excreted. The pump reduces or abrogates the need for repeated paracentesis in patients with recurrent or refractory ascites. AIMS: To improve outcomes for alfapump® implantation and pre- and post-implant patient management in both clinical trial and real-world settings by development of consensus recommendations. METHODS: The alfapump® working group consisting of hepatologists and surgeons with extensive experience in implantation of the alfapump® and patient management met on two occasions: (1) to determine the key areas where recommendations should be made; and (2) to discuss the experiences of the working group within those areas and formulate draft statements. Developed statements were submitted to the group and consensus sought on relevance and wording through a collaborative iterative approach in order to consolidate the recommendations into consensus statements. Only recommendations agreed upon unanimously were included. RESULTS: Twenty-three consensus recommendations were developed in the areas of pre-implantation procedure, (three statements), surgical implant procedure (11 statements), immediate post-implant care (three statements) and long-term management (six statements). CONCLUSIONS: The consensus statements are a valuable reference resource for physicians managing patients with the alfapump® and for those considering management strategies for patients with refractory ascites

    Consensus care recommendations for alfapump® in cirrhotic patients with refractory or recurrent ascites.

    Get PDF
    BACKGROUND The alfapump® is an implantable class III medical device that pumps ascitic fluid from the peritoneal space to the urinary bladder from where it is excreted. The pump reduces or abrogates the need for repeated paracentesis in patients with recurrent or refractory ascites. AIMS To improve outcomes for alfapump® implantation and pre- and post-implant patient management in both clinical trial and real-world settings by development of consensus recommendations. METHODS The alfapump® working group consisting of hepatologists and surgeons with extensive experience in implantation of the alfapump® and patient management met on two occasions: (1) to determine the key areas where recommendations should be made; and (2) to discuss the experiences of the working group within those areas and formulate draft statements. Developed statements were submitted to the group and consensus sought on relevance and wording through a collaborative iterative approach in order to consolidate the recommendations into consensus statements. Only recommendations agreed upon unanimously were included. RESULTS Twenty-three consensus recommendations were developed in the areas of pre-implantation procedure, (three statements), surgical implant procedure (11 statements), immediate post-implant care (three statements) and long-term management (six statements). CONCLUSIONS The consensus statements are a valuable reference resource for physicians managing patients with the alfapump® and for those considering management strategies for patients with refractory ascites

    Final safety and efficacy results from a 106 real-world patients registry with an ascites-mobilizing pump

    Get PDF
    Background and aims: Patients with cirrhotic refractory ascites ineligible for transjugular intrahepatic shunt (TIPSS) have limited treatment options apart from repeated large volume paracentesis. The alfapump® is an implantable device mobilizing ascites from the peritoneal cavity to the bladder, from where it can be excreted. The aim of this observational cohort study was to prospectively investigate safety and efficacy of the device in a real-world cohort with cirrhotic refractory ascites and contraindications for TIPSS. Methods: A total of 106 patients received an implant at 12 European centres and were followed up for up to 24 months. Complications, device deficiencies, frequency of paracentesis, clinical status and survival were recorded prospectively. Results: Approximately half of the patients died on-study, about a quarter was withdrawn because of serious adverse events leading to explant, a sixth were withdrawn because of liver transplant or recovery, and nine completed follow-up. The most frequent causes of on-study death and complication-related explant were progression of liver disease and infection. The device reduced the requirement for large-volume paracentesis significantly, with more than half of patients not having required any post-implant. Survival benefits were not observed. Device-related reinterventions were predominantly caused by device deficiencies. A post-hoc comparison of the first 50 versus the last 50 patients enrolled revealed a decreased reintervention rate in the latter, mainly related to peritoneal catheter modifications. Conclusions: The device reduced paracentesis frequency in a real-world setting. Technical complications were successfully decreased by optimization of management and device modification (NCT01532427)

    Final Safety and Efficacy Results from a 106 Real-World Patients Registry with an Ascites-Mobilizing Pump.

    No full text
    BACKGROUND & AIMS Patients with cirrhotic refractory ascites ineligible for transjugular intrahepatic shunt (TIPSS) have limited treatment options apart from repeated large volume paracentesis. The alfapump® is an implantable device mobilizing ascites from the peritoneal cavity to the bladder, from where it can be excreted. The aim of this observational cohort study was to prospectively investigate safety and efficacy of the device in a real-world cohort with cirrhotic refractory ascites and contraindications for TIPSS. METHODS A total of 106 patients received an implant at twelve European centers and were followed up for up to 24 months. Complications, device deficiencies, frequency of paracentesis, clinical status and survival were recorded prospectively. RESULTS Approximately half of the patients died on-study, about a quarter were withdrawn due to serious adverse events leading to explant, a sixth were withdrawn due to liver transplant or recovery, and nine completed follow-up. The most frequent causes of on-study death and complication-related explant were progression of liver disease and infection. The device reduced the requirement for large volume paracentesis significantly, with more than half of patients not having required any post-implant. Survival benefits were not observed. Device-related reinterventions were predominantly caused by device deficiencies. A post-hoc comparison of the first 50 vs. the last 50 patients enrolled revealed a decreased reintervention rate in the latter, mainly related to peritoneal catheter modifications. CONCLUSIONS The device reduced paracentesis frequency in a real-world setting. Technical complications were successfully decreased by optimization of management and device modification (NCT01532427)

    Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis

    No full text
    Background: Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA. Aim: To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS. Methods: Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded. Results: At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month. Conclusions: The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions

    Fc gamma receptor-TLR cross-talk elicits pro-inflammatory cytokine production by human M2 macrophages

    No full text
    M2 macrophages suppress inflammation in numerous disorders, including tumour formation, infection and obesity. However, the exact role of M2 macrophages in the context of several other diseases is still largely undefined. We here show that human M2 macrophages promote inflammation instead of suppressing inflammation on simultaneous exposure to complexed IgG (c-IgG) and TLR ligands, as occurs in the context of diseases such as rheumatoid arthritis (RA). c-IgG-TLR ligand co-stimulation of M2 macrophages selectively amplifies production of pro-inflammatory cytokines TNF-α, IL-1β and IL-6 and promotes Th17 responses, which all play a critical role in RA pathology. Induction of pro-inflammatory cytokines on c-IgG co-stimulation mainly depends on Fc gamma receptor IIa (FcγRIIa), which selectively amplifies cytokine gene transcription and induces caspase-1 activation. These data indicate that FcγR-TLR cross-talk may be targeted for treatment to attenuate inflammation in RA, by restoring the anti-inflammatory function of M2 macrophage