4,623 research outputs found
Contamination Control Handbook for Ground Fluid Systems Final Technical Publication
Handbook for contamination control of aerospace ground fluid systems and portable equipmen
Recommended from our members
Rapid and Accurate Pressure Sensing Device for Direct Measurement of Intraocular Pressure.
PurposeIntraocular pressure (IOP) is the primary modifiable risk factor for glaucoma. Current devices measure IOP via the dynamic response of the healthy cornea and do not provide the accurate IOP measurements for patients with altered corneal biomechanics. We seek to develop and test an accurate needle-based IOP measurement device that is not cornea dependent.MethodsOur device combines a high-resolution pressure microsensor with 30- and 33-gauge Luer lock needles to provide IOP measurements via a microcontroller and USB interface to a computer. The device was calibrated in a membrane chamber and then tested and validated in the anterior chamber and post-vitrectomy vitreous chamber of rabbit eyes. The results were compared to Tonopen readings across a pressure range of 0 to 100 mm Hg, imposed in increments of 10 mm Hg.ResultsBoth the needle based sensor device and the Tonopen demonstrated a linear relationship with changes in imposed pressure. The Tonopen was found to consistently underestimate the IOP both in the anterior and vitreous chambers. The Tonopen exhibited a significantly greater error than our needle-based sensor device. With increased pressure (>30 mm Hg), the error of the Tonopen increased, whereas the error of our device did not. The 30-gauge needle produces an insignificant improvement in accuracy over the 33-gauge needle.ConclusionsA needle-based sensor device enables accurate IOP measurements over a broad range of induced IOP.Translational relevanceDirect measurement of IOP in the anterior chamber circumvents the influence of corneal parameters on IOP measurement
Ninja data analysis with a detection pipeline based on the Hilbert-Huang Transform
The Ninja data analysis challenge allowed the study of the sensitivity of
data analysis pipelines to binary black hole numerical relativity waveforms in
simulated Gaussian noise at the design level of the LIGO observatory and the
VIRGO observatory. We analyzed NINJA data with a pipeline based on the Hilbert
Huang Transform, utilizing a detection stage and a characterization stage:
detection is performed by triggering on excess instantaneous power,
characterization is performed by displaying the kernel density enhanced (KD)
time-frequency trace of the signal. Using the simulated data based on the two
LIGO detectors, we were able to detect 77 signals out of 126 above SNR 5 in
coincidence, with 43 missed events characterized by signal to noise ratio SNR
less than 10. Characterization of the detected signals revealed the merger part
of the waveform in high time and frequency resolution, free from time-frequency
uncertainty. We estimated the timelag of the signals between the detectors
based on the optimal overlap of the individual KD time-frequency maps, yielding
estimates accurate within a fraction of a millisecond for half of the events. A
coherent addition of the data sets according to the estimated timelag
eventually was used in a characterization of the event.Comment: Accepted for publication in CQG, special issue NRDA proceedings 200
Methods for detection and characterization of signals in noisy data with the Hilbert-Huang Transform
The Hilbert-Huang Transform is a novel, adaptive approach to time series
analysis that does not make assumptions about the data form. Its adaptive,
local character allows the decomposition of non-stationary signals with
hightime-frequency resolution but also renders it susceptible to degradation
from noise. We show that complementing the HHT with techniques such as
zero-phase filtering, kernel density estimation and Fourier analysis allows it
to be used effectively to detect and characterize signals with low signal to
noise ratio.Comment: submitted to PRD, 10 pages, 9 figures in colo
Comparison of methods for H*(10) calculation from measured LaBr3(Ce) detector spectra
The Universitat Politecnica de Catalunya (UPC) and the Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) have evaluated methods based on stripping, conversion coefficients and Maximum Likelihood Estimation using Expectation Maximization (ML-EM) in calculating the H*(10) rates from photon pulse-height spectra acquired with a spectrometric LaBr3(Ce)(1.5¿ × 1.5¿) detector. There is a good agreement between results of the different H*(10) rate calculation methods using the spectra measured at the UPC secondary standard calibration laboratory in Barcelona. From the outdoor study at ESMERALDA station in Madrid, it can be concluded that the analysed methods provide results quite similar to those obtained with the reference RSS ionization chamber. In addition, the spectrometric detectors can also facilitate radionuclide identification.Postprint (author's final draft
Frequency noise and intensity noise of next-generation gravitational-wave detectors with RF/DC readout schemes
The sensitivity of next-generation gravitational-wave detectors such as
Advanced LIGO and LCGT should be limited mostly by quantum noise with an
expected technical progress to reduce seismic noise and thermal noise. Those
detectors will employ the optical configuration of resonant-sideband-extraction
that can be realized with a signal-recycling mirror added to the Fabry-Perot
Michelson interferometer. While this configuration can reduce quantum noise of
the detector, it can possibly increase laser frequency noise and intensity
noise. The analysis of laser noise in the interferometer with the conventional
configuration has been done in several papers, and we shall extend the analysis
to the resonant-sideband-extraction configuration with the radiation pressure
effect included. We shall also refer to laser noise in the case we employ the
so-called DC readout scheme.Comment: An error in Fig. 10 in the published version in PRD has been
corrected in this version; an erratum has been submitted to PRD. After
correction, this figure reflects a significant difference in the ways RF and
DC readout schemes are susceptible to laser noise. In addition, the levels of
mirror loss imbalances and input laser amplitude noise have also been updated
to be more realistic for Advanced LIG
The expression pattern of MUC1 (EMA) is related to tumour characteristics and clinical outcome of invasive ductal breast carcinoma
Aims: To clarify MUC1 patterns in invasive ductal breast carcinoma and to relate them to clinicopathological parameters, coexpression of other biological markers and prognosis. Methods and results: Samples from 243 consecutive patients with primary ductal carcinoma were incorporated into tissue microarrays (TMAs). Slides were stained for MUC1, oestrogen receptor (ER), progesterone receptor (PR), Her2/neu, p53 and cyclin D1. Apical membrane MUC1 expression was associated with smaller tumours (P = 0.001), lower tumour grades (P < 0.001), PR positivity (P = 0.003) and increased overall survival (OS; P = 0.030). Diffuse cytoplasmic MUC1 expression was associated with cyclin D1 positivity (P = 0.009) and increased relapse-free survival (RFS; P = 0.034). Negativity for MUC1 was associated with ER negativity (P = 0.004), PR negativity (P = 0.001) and cyclin D1 negativity (P = 0.009). In stepwise multivariate analysis MUC1 negativity was an independent predictor of both RFS [hazard ratio (HR) 3.5, 95% confidence interval (CI) 1.5, 8.5; P = 0.005] and OS (HR 14.7, 9 5% Cl 4.9, 44. 1; P < 0.001). Conclusions: The expression pattern of MUC1 in invasive ductal breast carcinoma is related to tumour characteristics and clinical outcome. In addition, negative MUC1 expression is an independent risk factor for poor RFS and OS, besides 'classical' prognostic indicators
Subarachnoid haemorrhage due to intracranial vertebral artery dissection presenting with atypical cauda equina syndrome features: case report
BACKGROUND: Failing to recognise the signs and symptoms of subarachnoid haemorrhage (SAH) causes diagnostic delay and may result in poorer outcomes. We report a rare case of SAH secondary to a vertebral artery dissection (VAD) that initially presented with cauda equina-like features, followed by symptoms more typical of SAH. CASE PRESENTATION: A 55-year-old man developed severe lower back pain after sudden movement. Over the next 5 days he developed paraesthesiaes in the feet, progressing to the torso gradually, and reported constipation and reduced sensation when passing urine. On day six he developed left facial palsy, and later gradual-onset headache and intermittent confusion. Magnetic resonance imaging of the brain showed diffuse subarachnoid FLAIR hyperintensity, concerning for blood, including a focus of cortical/subcortical high signal in the left superior parietal lobule, which was confirmed by computed tomography. Digital subtraction angiography demonstrated a left VAD with a fusiform aneurysm. CONCLUSION: We present a very rare case of intracranial VAD with SAH initially presenting with spinal symptoms. The majority of subsequent clinical features were consistent with a parietal focus of cortical subarachnoid blood, as observed on neuroimaging
Fire debris analysis by Raman spectroscopy and chemometrics
A paper reporting the use of Raman Spectroscopy in fire debris analysis is presented. Five polymer based samples, namely carpet (polypropylene), nylon stockings (nylon), foam packaging (polystyrene), CD cases (polystyrene) and DVD cases (polypropylene) were burnt with each one of the following ignitable liquids: petrol, diesel, kerosene and ethanol. Raman shifts were obtained and, in some cases, peaks were identified to correspond to pyrolysis products in the form of alkanes, aromatic or polyaromatic compounds. All pyrolysis peaks were used to produce a Principal Component Analysis (PCA) of the burned samples with the different ignitable liquids. The change in the Raman spectra made it possible to identify some of the pyrolysis products produced in the combustion and also to identify the different plastic materials in fire debris, even when different fuels have been used and the chemical and structural identity of the plastic has been altered in the fire
- …